The Vibro-Meter CA202 uses a symmetrical shear-mode piezoelectric element with internal case insulation and differential charge output. The hermetically welded stainless-steel housing and protected integral cable are designed for demanding machinery environments and elevated temperatures.
Order number 144-202-000-215 specifies the standard CA202 version with a 6 m integral cable and flying leads. It is intended to operate with a compatible charge converter such as an IPC70x measurement-chain component.
STANDARD VERSIONNon-hazardous-area configuration
6 mIntegral protected cable
FLYING LEADSCharge-converter connection
Measurement Chain
MECHANICAL INPUT TO MONITORING VALUE
MACHINECasing vibration
>
CA202Charge output
>
IPC70xCharge conversion
>
MONITORVibration value
The lower frequency limit and final engineering-unit scaling depend on the connected charge converter and monitoring channel. Match sensitivity, cable capacitance and converter setup as one measurement chain.
PART CHECKOrder number, cable and visible condition confirmation.
FAST RESPONSESupport for shutdown and maintenance needs.
12-month warranty and return supportContact us within 7 days if a problem is found. Keep the item in original condition and provide a clear return reason. Refund or replacement can be arranged after receipt and inspection. Return shipping is handled by the buyer.
Can CA202 144-202-000-215 be installed in a hazardous area?
This order number is the standard 6 m version, not the Ex version. Hazardous-area use requires the corresponding Ex order number and installation arrangement.
Can the 6 m cable on CA202 144-202-000-215 be shortened or replaced?
Treat the integral low-noise cable as part of the sensor assembly. Cable capacitance affects the charge measurement chain; changes require review of converter input and scaling.
Which temperature limit controls CA202 144-202-000-215 cable routing?
The sensor supports +260 degrees C continuously, but the integral cable is limited to +200 degrees C. Route and shield the cable according to the lower cable limit.
How should the monitoring channel be scaled for CA202 144-202-000-215?
Use the individual sensitivity value supplied with the sensor when available, then confirm charge-converter gain, cable capacitance, engineering units and alarm settings.
Which installation details most affect CA202 144-202-000-215 high-frequency accuracy?
Mount on a clean, flat and rigid surface with four M6 x 35 screws tightened to 15 N m. Poor flatness, loose mounting, cable movement and local base strain can distort the measured response.
Recommended Models
ADDITIONAL INDUSTRIAL PART NUMBERS
6DD1606-1AA0
5464-414
6ES7677-2DB42-0GB0
IS230TCATH1A
9907-028
PLN-10X1.5
6ES5312-3AB31
8I0IF248.300-1
UVC752
TLRP-3062L
2093-AM03
CNGP431FN-EXK
8290-184
GHGR 31.7-3
2094-BM03-M
TTEL25.4-2T17
UVL682
405-8ADC-1
SNAP-AITM
6DD1606-2AC0
9375-12UNJ-3B
PLX32-EIP-PND
5463-473
6ES5374-1KH21
UVV696
A-751-116-9B
KJ4006X1-BD1
2VBQ3-4N
6ES5316-8FA12
DW-AS-501-04
F8627X
SC1-1/2T1.000B
435-CPU
2093-AM05
IS220PDIAH1A
6DD1610-0AG1
505-4232
ACS580-01-07A3-4
X20CP3585
UHMT1
Check CA202 144-202-000-215 availability
Send the full order number, quantity, converter type, installation temperature and destination.