Six individually isolated analog input channels for voltage and current signal acquisition in Rockwell Automation ControlLogix systems.
01 / PRODUCT OVERVIEW
Isolated Analog Signal Acquisition
The Allen-Bradley 1756-IF6I belongs to the ControlLogix analog I/O family. It provides six individually isolated input channels for voltage and current signals, allowing field instrumentation measurements to be transferred into the controller for monitoring and process logic.
Signal flexibility
Each channel can be configured for its intended voltage or current input range. The module supports engineering-unit scaling, real-time sampling and onboard data alarming.
Product lifecycle: Rockwell Automation lists this catalog number as discontinued effective March 31, 2017. Its published replacement classification is Functional Replacement, not a guarantee of direct interchangeability.
02 / APPLICATION & FAILURE SCENARIOS
Where This Module Matters
The 1756-IF6I is used in ControlLogix I/O configurations that require isolated analog measurements from field instruments.
Typical signal sources
Voltage-output instruments, current-loop transmitters and other compatible process measurement devices.
Typical system applications
Process monitoring, industrial instrumentation acquisition and ControlLogix-based automation systems.
WHY CUSTOMERS SEARCH FOR THIS PART
A missing analog reading, unstable channel value, wire-off indication, module fault or failed input channel may lead maintenance teams to search for a replacement.
⌁ ↓
If the affected measurements are required by controller logic, loss of reliable input data can disrupt process regulation, trigger alarms or contribute to production interruption and unplanned downtime.
03 / ENGINEERING DATA
Technical Specifications
Manufacturer-published specifications for catalog number 1756-IF6I.
Integer (left-justified, 2's complement); IEEE 32-bit floating point
Input impedance
Voltage: greater than 10 MΩ Current: 249 Ω
Channel bandwidth
15 Hz (-3 dB)
Accuracy, Isolation & Protection
Calibrated accuracy at 25°C
Better than 0.1% of range
Module error
0.54% of range
Isolation voltage
250 V continuous, basic insulation type
Isolation test
1350 V AC for 2 seconds, routine tested
Normal-mode noise rejection
60 dB at 60 Hz
Common-mode noise rejection
120 dB at 60 Hz; 100 dB at 50 Hz
Overvoltage protection
Voltage: 120 V AC/DC maximum Current: 8 V AC/DC maximum
Open-circuit detection
Positive full-scale reading within 5 seconds
Settling time
Less than 80 ms to 5% of full scale
Electrical & Mechanical Data
Current draw at 5.1 V
250 mA
Current draw at 24 V
100 mA
Total backplane power
3.7 W
Maximum power dissipation
Voltage: 3.7 W Current: 4.3 W
Thermal dissipation
Voltage: 12.62 BTU/hr Current: 14.32 BTU/hr
Input scan time
Minimum 25 ms (floating point); 10 ms (integer)
Slot width
1 slot
Connection
20-pin removable terminal block interface
Supported RTB
1756-TBNH / 1756-TBSH
Enclosure type
Open-style
Environmental Specifications
Operating temperature
0–60°C
Storage temperature
-40–85°C
Relative humidity
5–95%, noncondensing
Vibration
2 g at 10–500 Hz
Operating shock
30 g
Temperature code
North America: T4A; IEC: T4
Specifications are based on Rockwell Automation publications 1756-TD002 and 1756-UM009. Confirm the hardware revision and installation requirements against the actual unit before integration.
04 / SYSTEM INTEGRATION
Wiring, Configuration & Diagnostics
The module supports individual channel configuration for voltage or current measurement. Rockwell's user manual documents field-side wiring arrangements for voltage inputs and two-wire and four-wire current transmitters.
Field connections
The 20-pin terminal arrangement provides IN-x/V, IN-x/I and RET-x connections for the six channels. For two-wire current transmitter applications, the manufacturer specifies that IN-V and IN-I must be wired together.
Configuration
Configuration includes input range, signal scaling, data format and channel-related settings. The module also supports field calibration for voltage and current applications.
Fault monitoring
Channel status and fault data are reported to the owner and/or listening controller. Wire-off conditions can produce overrange or underrange indications depending on the input type and operating mode.
Installation, wiring, calibration and troubleshooting should follow the applicable Rockwell Automation instructions and the actual controller project configuration.
05 / INDUSTRIAL PARTS SOURCING
AMIKON Industrial Supply
Industrial Parts Sourcing, Kept Practical.
AMIKON supports industrial automation spare-part sourcing with a focus on accurate part-number identification, practical order coordination and clear communication. Our team assists customers in locating components for maintenance, repair and equipment replacement requirements.
A practical sourcing process
Part identification → Availability coordination → Inspection arrangements → Export packing → Order follow-up
Testing: Inspection and functional testing according to the agreed quotation and available test scope.
Packaging: Protective industrial export packaging appropriate to the shipment.
Returns & DOA: Report damaged or non-working items promptly with supporting evidence. Return authorization and DOA handling follow the agreed order terms.
Warranty: 12 months, subject to quotation terms and confirmed product condition.
REQUEST A QUOTATION
Enquire About 1756-IF6I
For accurate sourcing and order coordination, please include the following information in your enquiry:
Part Number · Quantity · Destination · Required Date · Machine/System Model
Email your requirements to sales@amikon.cn for pricing and availability.
07 / PRODUCT FAQ
Frequently Asked Questions
01 / What signals does the 1756-IF6I accept?
It accepts configurable voltage and current inputs, including ±10.5 V, 0–10.5 V, 0–5.25 V and 0–21 mA ranges.
02 / Are the six input channels individually isolated?
Yes. The module provides six individually isolated inputs, with 250 V continuous isolation between input channels and between input channels and the backplane.
03 / Which removable terminal blocks are specified for this module?
Rockwell Automation lists the 1756-TBNH and 1756-TBSH as compatible removable terminal block options. The terminal block is ordered separately.
04 / How does the 1756-IF6I report an input wiring fault?
It provides channel fault and status information to the controller. Wire disconnection can generate overrange or underrange indications depending on the signal type and data format.
05 / Is the 1756-IF6I still manufactured by Rockwell Automation?
No. Rockwell Automation lists it as discontinued effective March 31, 2017. Its published replacement category is Functional Replacement. Customers should verify the specific replacement requirements before changing their system configuration.
08 / AMIKON PRODUCT RANGE
Related Models
Additional industrial automation part numbers from the AMIKON sourcing range. These are sourcing references only and do not imply technical compatibility with the 1756-IF6I.
View Related Models (68 Part Numbers)
RKL0013/010-13W16
NT100-RE-DN/+ML
NT100-RE-DP/+ML
6SL3100-1AE31-0AB0
8BOC0160HW00.001-1
DW 812.91
PZ-41
1756-L73S
DGM60-ASAK
WTB9-3P2411S14
CVSE2-15A-30-02G-3
8BVI0110HCD8.000-1
6ES7322-1BL00-0AA0
1756-OF4
1794-IB16
1794-OB32P
1756-M16SE/A
NT50-DN-EN
4XP0000.00-K95
7TB718.91
1756-M16SE
E-B-177
WT34-B420
3RV2721-4CD10
6DS1102-8AB
8B0C0320HC00.00A-1
3SF1324-1SD21-1BA4
PBMX 110080005
1794-IA8
IC200MDL930
140 CPU 534 14A
MGB-H-AA1A6-R-111838
SM2337D
EDS-408A
CIFX50-RE
1794-OA8
1794-AENT
1756-L62/B
1794-PS1
DFM-25-40-P-A-GF
SSR20XW2SSC1
DSNU-63-30-PPV-A-MQ-R3
RK76
1794-OB16
6ES5955-3NC13
PD40134-0305
1756-DNB/E
IC200CHS022L
2711P-T10C4D6
CIF50-ASM
7TB718.9
1756-ENBT
6GK1704-1LW64-3AA0
CIFX50E-RE
331-C-03
NT50-DP-EN
1756-OW16I
2711P-RDT10C
1794-IB32
8B0C0160HW00.001-1
E5EN-Q3MTC-500
CIF50-DNM
SC-4-1G
FCD305PT4P66EXR1DCF10T52C0
1756-IB16I
1747-L551
3-5SV4000-331
NT50-CC-EN
TECHNICAL REFERENCE
For engineering reference, consult the Rockwell Automation 1756-IF6I PDF/manual/datasheet documentation for detailed specifications, wiring arrangements, configuration procedures and calibration instructions. Verify the hardware revision and application requirements before ordering or installation.
AMIKON Industrial Supply · Industrial Automation Parts Sourcing