Allen-Bradley 1746-OB16 SLC 500 16-Point DC Digital Output Module

16-Point DC Transistor Output

10–50V DC Output Signal Range

1746-OB16 manual

Place of Origin:

USA

Brand Name:

Allenbradley

Contact Us
Request A Quote
Product Details
Highlight:

16-Point DC Transistor Output

,

10–50V DC Output Signal Range

,

1746-OB16 manual

Payment & Shipping Terms
Minimum Order Quantity
1
Packaging Details
Brand new and original
Delivery Time
2-3 work days
Payment Terms
T/T
Supply Ability
in Stock
Product Description

AMIKON Industrial Supply / SLC 500 Series

Allen-Bradley 1746-OB16


Request a Quote
Allen-Bradley 1746-OB16 SLC 500 digital DC output module
Product ImagE
Product Overview

The Allen-Bradley 1746-OB16 is a 16-channel DC transistor output module for the SLC 500 programmable controller system. Its sourcing output arrangement switches external DC field circuits through individual output points.

It is used in SLC 500 installations where controller outputs operate DC field devices. For replacement sourcing, check the installed catalog number, field supply, output loading and chassis arrangement before ordering.

Module Identification 1746-OB16
Manufacturer: Allen-Bradley / Rockwell Automation
Platform: SLC 500
Function: DC Transistor Output
Output Arrangement: Sourcing
01

Technical Specifications

MODULE 1746-OB16 SLC 500
16 OUTPUTS Digital Points
10–50 V DC Output Signal Range
0.50 A PER POINT Continuous at 30°C
0.25 A PER POINT Continuous at 60°C
8.0 A PER MODULE Maximum at 30°C
4.0 A PER MODULE Maximum at 60°C
1.2 V MAX DROP At 0.50 A
3.0 A 10 ms Surge per Point
Highlighted electrical rating Additional module rating
Additional Module Data
Manufacturer Allen-Bradley / Rockwell Automation
Product Family SLC 500
Module Type Digital DC transistor output module
Output Configuration Current sourcing
Voltage Category 24V DC signal output
Points per Common 16
Signal Delay – Resistive Load ON: 0.1 ms maximum; OFF: 1.0 ms maximum
Backplane Current Consumption 5V DC: 0.280 A; 24V DC: 0 A
Programming ID Code 2913
Terminal Block Removable terminal block
UPC 662468067058
Current ratings depend on ambient temperature. At 60°C, the continuous current limits are lower than the 30°C ratings. Assess both the individual output load and total module current.
02

Application & Failure Scenarios

The 1746-OB16 is installed in an SLC 500 I/O chassis to provide discrete DC output signals to field devices. In a machine or process-control sequence, these outputs can be used to switch compatible DC control circuits.

Installed Control Application

Used as part of an SLC 500 controller's discrete output section, where individual output points control external DC field circuits.

Output Point Fails to Switch

A PLC command is present but the connected field device does not respond. Maintenance teams may investigate the output module, field supply, wiring and load circuit.

Intermittent Field Response

Unstable output operation can interrupt machine sequences, cause repeated troubleshooting and delay the return of equipment to normal operation.

Replacement During a Shutdown

When the installed module is identified as faulty, sourcing the correct catalog number helps reduce the time required for repair planning and system restart.

03

Wiring & Installation

Terminal arrangement: The 1746-OB16 uses a removable terminal block. Its wiring arrangement includes DC supply and common connections with sixteen transistor output points.
+DC −DC DC COM OUT 0 OUT 1 OUT 2 OUT 3 OUT 4 OUT 5 OUT 6 OUT 7 OUT 8 OUT 9 OUT 10 OUT 11 OUT 12 OUT 13 OUT 14 OUT 15

Before Installation

Disconnect power to the chassis before installing, removing or wiring the module. Confirm the intended slot and check the field wiring against the applicable SLC 500 installation instructions.

Module Insertion

Align the module circuit board with the chassis card guide and slide the module into the chassis until the retaining tabs lock.

Field Wiring

Route field wiring down and away from the module, and secure the wiring appropriately. Observe the specified conductor and terminal limits.

Removal

Use the module release tabs to remove the module from its slot after the chassis power has been disconnected.

Maximum conductor size: 2 mm² (14 AWG).
Maximum two wires per terminal.
Maximum terminal torque: 0.9 Nm (8 lb-in.).
The first chassis slot is reserved for the processor or 1747-ASB module.
Unused chassis slots should be covered with a 1746-N2 card slot filler.
Electrical safety: Never install, remove or wire the module with power applied to the chassis. Disconnect power before servicing the module or removable terminal block.
04

Inspection & Troubleshooting

When an output-controlled device does not respond, trace the control path before deciding whether the module needs replacement.

01 / Controller Command Compare the PLC output command with the corresponding channel indication.
02 / DC Field Supply Check the external DC supply, polarity and common connection.
03 / Terminal Connections Inspect the removable terminal block and field wiring for loose or damaged connections.
04 / Connected Load Check the connected device and field circuit for short circuits or abnormal current demand.
05 / Output Loading Compare the load with the per-point and total module current limits.
06 / Surge Suppression For 24V DC inductive loads, Rockwell recommends a reverse-wired 1N4004 diode across the load.
A field supply problem, wiring fault, load issue, controller command or output module fault can produce similar symptoms. Isolate the cause before replacing the module.
05

Lifecycle & Replacement Considerations

Discontinued Date 30 Sep 2024

Lifecycle category: Engineering Replacement.

Rockwell Automation lists the 1746-OB16 as discontinued. The engineering replacement category does not identify a specific drop-in replacement part. Before selecting another module, compare output type, field voltage, current requirements, terminal arrangement and controller configuration.

06

Manufacturer Documentation

1746-IN027
SLC 500 Digital I/O Modules Installation Instructions
Includes 1746-OB16 specifications, wiring information, installation procedures and terminal wiring limits.
1747-SG001
SLC 500 System Selection Guide
Provides SLC 500 I/O module selection information, including sourcing DC output module characteristics.
1747-UM011
SLC 500 Modular Hardware Style User Manual
Referenced by Rockwell Automation for additional information on inductive-load surge suppression and output transient pulses.

Search reference: 1746-OB16 manual and SLC 500 digital I/O installation documentation.

07

Frequently Asked Questions

01

Is the 1746-OB16 a sourcing or sinking output module?

It is a sourcing DC transistor output module for the SLC 500 platform.

02

What is the operating output signal range?

The specified output signal range is 10–50V DC. The module is categorized as a 24V DC signal output module.

03

What is the continuous current limit per output point?

The limit is 0.50 A per point at 30°C and 0.25 A per point at 60°C. The maximum continuous current per module is also temperature-dependent.

04

Can the 1746-OB16E be treated as the same module?

No. The 1746-OB16E is a separate catalog number with different electrical specifications. Check the exact part number and system requirements before ordering.

05

What should be checked before installing a replacement?

Check the catalog number, sourcing output arrangement, field supply, load current, wiring and chassis configuration. Disconnect chassis power before installation or wiring.

08

Related Models

09

Delivery & Warranty

Pre-shipment Checks Part number and available condition checked against the order.
Export Packaging Protective packaging arranged for international shipment.
12-Month Warranty Subject to the agreed quotation terms and supplied condition.
DOA & Returns Report issues promptly with order details and photos. Returns require prior authorization and inspection.

For quotation: Please provide the following details with your inquiry.

Part Number Quantity Destination Required Date Machine/System Model
10

About AMIKON

AMIKON supports industrial automation spare-part sourcing with practical order coordination, product identification and international delivery arrangements.

AMIKON industrial automation sourcing and service team
Industrial Parts Sourcing

Talk to AMIKON

Contact Person Miya Zheng

Send your inquiry directly to us