PR6426/010-010 measures radial or axial shaft position on large turbines, compressors, pumps and fans. Its 32 mm sensing head provides an 8 mm total static span for machines where a smaller probe cannot cover the required movement.
Configuration focus: the /010-010 arrangement combines an armored 5 m cable with a LEMO end. Cable construction and length belong to the calibrated measuring chain.
CHAIN LOGIC
Probe → cable → CON021 → monitor
Treat these elements as one calibrated path. Substituting a different suffix can shift sensitivity, center gap or usable span.
CALIBRATED ENVELOPE
Technical profile
Probe / range
32 mm / +/-4.0 mm static position
Sensitivity
2 V/mm, maximum +/-1.5%
Center / target
Approx. 5.5 mm / 42CrMo4 steel
Shaft / clearance
200 mm minimum shaft / 80 mm ferrous-free zone
Temperature
-35 to +180 C at the sensor
Cable / converter
Armored 5 m cable, LEMO end / CON021
Installation acceptance route
01
FREE SPACE
Keep nearby steel outside the required zone.
→
02
CENTER GAP
Set near 5.5 mm and prove the full movement.
→
03
ARMOR ROUTE
Avoid crushing, tight bends and ground loops.
→
04
CHAIN TEST
Verify polarity, sensitivity, noise and monitor scale.
AMIKON / INDUSTRIAL SPARES SINCE 2005
Keep critical machinery moving.
Amikon supports global industrial users with PLC, HMI, DCS, industrial PC, drive and machinery-protection spares. Our team helps resolve exact suffixes and complex replacement requirements so planned work is not delayed by an incompatible part.
↻ Return support: Notify us within 7 days if an issue is found. Keep the item in original condition and provide the return reason. Return or replacement proceeds after receipt and inspection; shipping costs remain with the buyer.
PURCHASING AND COMMISSIONING
PR6426/010-010 CON021 FAQ
01 Can PR6426/010-010 CON021 replace a different PR6426 suffix? Only after the armor, total cable length, cable end, converter calibration and hazardous-area requirements match. The probe diameter alone does not establish interchangeability.
02 Why can PR6426/010-010 CON021 drift after a mechanically correct installation? Nearby ferrous material, target metallurgy, armor grounding, connector condition or an unmatched converter can shift the electrical center and sensitivity.
03 What must be recorded before removing PR6426/010-010 CON021? Capture every suffix, serial, cold gap voltage, probe location, target material, cable routing, armor grounding, converter identity and monitor scale.
04 How should the PR6426/010-010 CON021 armor be grounded? Preserve the machine's established single-point grounding arrangement. Additional bonds can create circulating currents and increase measurement noise.
05 What acceptance test is appropriate for PR6426/010-010 CON021? Verify the mechanical center gap, full usable movement, polarity, sensitivity, armor continuity, noise level, converter output and monitor alarm scaling before returning protection to service.