PR6423 is a non-contact eddy-current probe family for radial or axial shaft displacement, position, eccentricity and speed/key applications. The probe is used with a compatible converter; CON041 supplies excitation, linearizes the sensor response and provides the voltage signal.
Standard PR6423 chain 2.0 mm measuring range Linearity error up to 1.0% CON041 DIN-rail mounting 0-20 kHz frequency range
02 / MATCHED COMPONENTS
Parameter
PR6423/002-001
CON041
Role
Eddy-current probe
Signal converter
Probe family size
8 mm tip family
Matched for PR6422/23/24/26
Standard range
2.0 mm with matched CON041
PR6423 standard range: 2.0 mm
Frequency range
Defined by the complete chain
0-20,000 Hz (-3 dB)
Mounting
Machine bearing or bracket
DIN rail, screw terminals
Protection class
Application dependent
IP20
Mechanical Gap to Electrical Signal
SHAFT TARGET Conductive surface
→
PR6423 Non-contact gap sensing
→
CON041 Excitation and conversion
→
MONITOR Static / dynamic voltage
Probe, cable length, converter calibration and target material form one measuring chain. Mixing unmatched pieces can shift zero, sensitivity and linearity even when the connectors fit.
AMIKON / ESTABLISHED 2005
Global support for hard-to-find automation spares.
Founded in Hong Kong in 2005, Amikon has built a broad range covering PLC, HMI, DCS, industrial PC and VFD spares for customers worldwide.
Our experienced team helps with exact part-number searches and complex spare requirements to keep production running.
Return support: Contact us within 7 days if an issue is found. Items must remain in original condition and include the return reason. Return or replacement follows receipt and inspection; buyer covers shipping costs.
PR6423/002-001 CON041 FAQ
Can PR6423/002-001 CON041 be assembled from any PR6423 probe and any CON041? Not safely. Confirm probe suffix, cable arrangement, converter calibration, measuring range and target material as one chain.
Why can PR6423/002-001 CON041 show the correct gap but incorrect vibration amplitude? Static gap can appear plausible while sensitivity, converter calibration, cable length or target material causes dynamic scaling error.
What gap checks matter for PR6423/002-001 CON041 installation? Set the probe inside the linear range, confirm shaft runout and target geometry, then verify DC gap voltage through a full slow-roll cycle.
What should be captured before replacing PR6423/002-001 CON041? Record all suffixes, serial markings, cable length, converter adjustment, mounting depth, gap voltage, target material and monitor scaling.