logo
Home > Products > Yokogawa Module >
Yokogawa AAM11 Analog Input Module – Current / Voltage Input for CENTUM

Yokogawa AAM11 Analog Input Module – Current / Voltage Input for CENTUM

Yokogawa AAM11 analog input module

current voltage input CENTUM

Yokogawa module for CENTUM

Place of Origin:

JAPAN

Brand Name:

Yokogawa

Contact Us
Request A Quote
Product Details
Quotation Time:
Quick Quote Within 24 Hours
MOQ:
1 Piece
Shipping:
TNT, DHL, FedEx, EMS, UPS
Highlight:

Yokogawa AAM11 analog input module

,

current voltage input CENTUM

,

Yokogawa module for CENTUM

Payment & Shipping Terms
Minimum Order Quantity
1
Packaging Details
Brand new and original
Delivery Time
2-3 work days
Payment Terms
T/T
Supply Ability
in stock
Product Description
A
YOKOGAWA / CENTUM CONTROL SYSTEM
AAM11
Current / Voltage Input Module
Analog signal acquisition module for current and voltage field signals, featuring software-defined input specifications and RIO I/O installation architecture.
01 / OVERVIEW
Product
Architecture

Analog signal acquisition for process control.
Analog Signal Acquisition for Process Control

The Yokogawa AAM11 receives analog field signals and makes measurement information available to the control system. It supports voltage input and current input, including signals from two-wire transmitters and standardized analog signal sources.

Input signal types and ranges are configured through software. The module is installed in an appropriate I/O Module Nest and connected through the nest terminals.

Documentation: Refer to the manufacturer documentation for AAM11 electrical characteristics, accuracy, isolation and installation requirements.
02 / ARCHITECTURE
Signal
Pathway

Field input to the control system.
ANALOG INPUT CONNECTION
FIELD
Transmitters
→
AAM11
Analog Input
→
RIO
I/O Nest
Functional relationship for product orientation. Actual system configuration depends on the installed control system.
03 / ENGINEERING
Technical
Specifications

Manufacturer-published technical data.
AAM11 / TECHNICAL DATA REGISTER
01 — Input Signal & Electrical Characteristics
INPUT SPECIFICATIONS
MODEL
AAM11
VOLTAGE INPUT
0 to 10 V DC
CURRENT INPUT
0 to 20 mA DC
VOLTAGE INPUT RESISTANCE
1 MΩ
100 kΩ at power-down
CURRENT INPUT RESISTANCE
250 Ω
ALLOWABLE INPUT VOLTAGE
-10 to 30 V DC
ALLOWABLE INPUT CURRENT
≤ 40 mA DC
TRANSMITTER POWER SUPPLY
25.0–25.5 V DC
TRANSMITTER OUTPUT CURRENT LIMIT
≤ 60 mA DC
02 — Output, Accuracy & Performance
AUXILIARY VOLTAGE OUTPUT
1 to 5 V DC
AUXILIARY OUTPUT RESISTANCE
≤ 1 Ω
AUXILIARY OUTPUT LOAD RESISTANCE
≥ 10 kΩ
VOLTAGE INPUT ACCURACY
±4 mV
CURRENT INPUT ACCURACY
±16 μA
AUXILIARY OUTPUT ACCURACY
±12 mV
DATA UPDATE PERIOD
50 ms
AMBIENT TEMPERATURE EFFECT / 10°C CHANGE
Voltage: ±4 mV and ±0.15% of indicating value; Current: ±32 μA; Auxiliary output: ±24 mV
SQUARE ROOT EXTRACTION
Available by specification
03 — Power, Isolation & Installation
CURRENT CONSUMPTION
≤ 300 mA
5.0 V DC
SIGNAL ISOLATION
Input signals insulated between systems
WITHSTANDING VOLTAGE
1500 V AC / 1 min
INSTALLATION
I/O Module Nest
WIRING CONNECTION
Nest terminals / M4 screws
INPUT CONFIGURATION
Software setting
Signal engineering note: When AAM11 power is OFF or an abnormal condition occurs, the current input loop becomes open. Do not share current signals directly with other receivers. For signal sharing, Yokogawa specifies a 250 Ω shunt resistance and voltage-mode connection. Verify the complete wiring arrangement against the manufacturer's instructions.
04 / APPLICATION
Failure &
Downtime

Maintenance and replacement scenarios.
When an Analog Input Module Matters

AAM11 is used in Yokogawa CENTUM RIO analog input applications where field transmitter and voltage signals must be acquired by the control system.

Typical sourcing situations
  • Missing or unstable process measurements lead to suspected input-module faults.
  • A current or voltage input channel requires inspection or module replacement.
  • Maintenance teams need an original-part reference during a CENTUM system overhaul.
  • Signal acquisition problems require checking the module, field wiring and transmitter together.
Operational downtime exposure

Loss of a required analog measurement can reduce process visibility and affect control functions that depend on that signal. Depending on the process design, maintenance may need to verify the transmitter, wiring, input channel and control-system response before restoring normal operation.

05 / INSTALLATION
Wiring &
Configuration

Terminal and mounting reference.
Mounting and Field Connections

AAM11 is mounted in an I/O Module Nest. Field signal cables are connected to the designated nest terminals using M4 screw connections.

TERMINAL ASSIGNMENT
A
Two-wire transmitter input +
B
Two-wire transmitter input - / Current input + / Voltage input +
C
Current input - / Voltage input -
Configuration reminder: Input signal types and ranges are software-defined. Confirm the existing channel configuration and field wiring before replacing a module. Terminal assignments depend on the selected input type.
06 / AMIKON INDUSTRIAL SUPPLY
Industrial Control Components, Ready for Your Next Project.

AMIKON supports industrial maintenance and procurement teams with component sourcing, order coordination and practical assistance for automation spare parts.




AMIKON industrial automation parts sourcing and service team


INDUSTRIAL SOURCING   /   ORDER SUPPORT   /   CUSTOMER SERVICE
YOUR SALES CONTACT
Miya Zheng
EMAIL
sales@amikon.cn
WHATSAPP
+86 180 2077 6792
ORDER & AFTER-SALES SUPPORT
Inspection
Pre-dispatch checks, as applicable to the quoted order.
Packaging
Protective packaging arranged for shipment.
DOA / Returns
Report arrival damage or suspected DOA promptly with supporting evidence. Returns require prior authorization.
Warranty
12 months, subject to quotation terms and agreed warranty conditions.
07 / RFQ
Request a
Quotation

A few details for accurate sourcing.
Send Your AAM11 Inquiry

Please include the following information in your inquiry:

Part Number
AAM11
Quantity
Required quantity
Destination
Shipping country / city
Required Date
Expected delivery date
Machine/System Model
Installed equipment information
08 / TECHNICAL QUESTIONS
Frequently Asked Questions

Q1 / INPUT
What input signals does the AAM11 support?
→
The AAM11 supports 0 to 10 V DC voltage input and 0 to 20 mA DC current input. Its input specifications are configured through software.
Q2 / MODEL DIFFERENCE
Is AAM11 the same as AAM11B?
→
No. They are separately identified models. AAM11B is the version documented as supporting BRAIN communication. Do not assume this function is available on AAM11.
Q3 / INSTALLATION
How is AAM11 installed and connected?
→
It is installed in an I/O Module Nest and connected to the nest terminals using M4 screw connections. The correct terminal assignment depends on the input signal type.
Q4 / POWER CONDITION
What happens to the current input loop if the module loses power?
→
According to Yokogawa's documentation, the current input loop becomes open when AAM11 is powered off or an abnormal condition occurs. Signal sharing requires the specified shunt-resistance arrangement.
Q5 / REPLACEMENT
What should be checked before ordering a replacement AAM11?
→
Confirm the exact model marking, existing I/O Nest, signal type, channel wiring and software configuration. Provide the installed system information when requesting a quotation.
09 / ADDITIONAL SOURCING REFERENCES
Related Models

Additional industrial parts available for sourcing inquiries. These are independent product references, not a statement of technical compatibility with AAM11.

VIEW RELATED MODELS +
Model Reference Model Reference Model Reference
Crestron ST-SPL 6500474 X201F2772 8BAC0120.001-2
FST-851 Honeywell XF521 5B47-B-11
Honeywell P8000A0016G EXB-1 Allen-Bradley 889D-F4AC-2
6SL3320-1TE32-6AA3 6SL3352-1AE41-4FA1 3SB1831-7AH
Notifier FSM500 X20IF2772 AC0123
S82K-03012 Schneider 140ACI03000 6RA7078-6DV62-0
8BVP0880HW00.000-1 6FC5210-0DF33-2AA0 6SE7031-2HF84-1BG0
X20MM4456 6SL3320-1TE32-1AA3 AC0120
X20SL8100 Beckhoff KL9510 X20S04110
8BVI0028HWD0.000-1 Veris TWXH00 B&R X20DO4529
6SL3040-1LA01-0AA0 6SN1118-0DJ23-0AA1 6SE7090-0XX84-0BJ0
Siemens 3RH1921-1EA11 M-BUS-RS232 6SL3353-1AG41-8DA1
8BAC0124.000-1 Legrand 077662L 6SL3352-1AE32-1AA1
AC0120-2 RK 271 016-AN 8BAC0122.000-1
Siemens AQR2531ANW 6AU1445-2AD00-0AA0 BIP-1300
AC0124 9SUB/B/FRONT/Q 2959560 AC0121
Beckhoff KL4032 HD-DA4-4KZ-E 6SE7090-0XX84-1GA1
RXSF1-110-125V

AMIKON INDUSTRIAL SUPPLY
Industrial Automation Parts Sourcing & Customer Support