4-Channel Isolated Analog Input Module
REQUEST A QUOTE →1746SC-INI4VI is a Spectrum Controls isolated analog input module for Allen-Bradley SLC 500 systems. It provides four individually configurable channels for acquiring current or voltage signals from field instrumentation.
Designed for analog measurement within an SLC 500 I/O rack, the module supports independent channel selection and software-based setup. Its onboard functions include programmable filtering, automatic calibration and error checking.
Technical data is arranged as four reference chapters. The main signal and performance sections are opened for quick review; installation and environmental details remain available below.
| Number of Channels | 4 differential, individually isolated channels |
|---|---|
| Current Input Ranges | 0–20 mA; 4–20 mA |
| Voltage Input Ranges | 0–5 VDC; 1–5 VDC; 0–10 VDC; -10 to +10 VDC |
| Input Selection | Current or voltage, selectable independently by channel |
| Conversion Method | Sigma-Delta A/D conversion |
| Resolution | 16-bit |
| Current Resolution | 312.8 nA per count |
| Voltage Resolution | 312.8 µV per count |
| Input Impedance | Current: less than 250 Ω; voltage: greater than 220 kΩ |
| Current Input Accuracy | 0.10% of full scale at 25 °C; 0.25% at 60 °C (datasheet) |
|---|---|
| Voltage Input Accuracy | 0.25% of full scale at 25 °C and 60 °C (datasheet) |
| Selectable Filter Frequencies | 50 Hz, 60 Hz, 250 Hz and 500 Hz |
| Minimum Update Time — Current | 14 ms with 500 Hz filters and all channels enabled |
| Minimum Update Time — Voltage | 18 ms with 500 Hz filters and all channels enabled |
| Step Response | 8 ms at 500 Hz; 16 ms at 250 Hz; 66.7 ms at 60 Hz; 80 ms at 50 Hz |
| Common-Mode Rejection | 99 dB at 1 kHz, 25 °C; 150 dB at 60 Hz (datasheet) |
| Normal-Mode Rejection | 98 dB at 50 Hz and 60 Hz (datasheet) |
| Calibration | Factory calibrated; automatic calibration can be enabled |
| Opto-Electrical Isolation | 750 VDC channel-to-channel and field wiring-to-backplane (manual) |
|---|---|
| Continuous Isolation Rating | 125 VAC continuous for field wiring-to-backplane and channel-to-channel (datasheet) |
| Input Overcurrent Protection | 33 mA continuous; 70 mA transient |
| Input Overvoltage Protection | 50 VDC continuous, INI4VI only |
| Diagnostics | Startup diagnostic tests, onboard error checking, channel status bits and LED indicators |
| Open-Circuit Detection | Open input circuit indication; response state is selectable |
| LED Indicators | Four green channel status indicators and one green module status indicator |
| Thermal Dissipation | 3.25 W maximum |
| Backplane Current | 550 mA at 5 VDC; 0 mA at 24 VDC (typical) |
|---|---|
| Backplane Power | 2.75 W typical |
| Rack Slot | Any 1746 I/O module slot except slot 0 |
| Terminal Block | Removable terminal block, supplied |
| Wire Size | One 12–24 AWG wire per terminal, maximum |
| Recommended Cable | Shielded twisted-pair; Belden 8761 or equivalent |
| Operating Temperature | 0 to 60 °C (32 to 140 °F) |
| Storage Temperature | -40 to 85 °C (-40 to 185 °F) |
| Relative Humidity | 5–95%, non-condensing |
| Hazardous Location Classification | Class I, Division 2, Groups A, B, C and D |
| Certifications | UL/cUL, CE, UKCA, FCC and CMIM (datasheet) |
Configuration and troubleshooting are organized around channel setup, signal review and module status.
Channel configuration: Set the enable state, input range, data format and filter frequency for each channel through the module configuration settings.
Signal and status review: Use input data and status words to review channel readings, configuration state and reported errors. For fault investigation, inspect open-input indications, range status, channel errors, field wiring and LED states.
In an SLC 500 control system, the module receives isolated current or voltage signals from field instrumentation for PLC monitoring and process control.
Missing, unstable or unexpected readings can lead maintenance teams to inspect the field signal, input wiring, channel settings and module condition.
Open-input indications, range errors or channel status faults may prompt checks of the sensor loop, terminal connections and input module.
Unreliable analog measurements can affect dependent monitoring or control functions. Accurate part identification helps reduce replacement delays during maintenance.
AMIKON supports industrial maintenance and automation sourcing through product identification, supply coordination and quotation assistance. Share your part number and application details with our team.
For availability, supply condition and quotation details, contact our industrial parts team.