The Allen-Bradley 1734-IB8S is a POINT Guard I/O safety digital input module designed to monitor safety devices and communicate safety input data through CIP Safety networks. It is intended for use within a configured industrial safety architecture.
Monitors emergency-stop input circuits as part of a configured machine safety function.
Receives safety status from guard-door and interlocking switch circuits.
Monitors safety sensor signals used to protect machine access and operating areas.
Typical sourcing triggers include a safety input channel fault, an input circuit that remains OFF, wiring or test-pulse diagnostic errors, or a module that no longer reports the expected safety input status. If the affected safety circuit cannot be validated, the machine may be unable to complete its safety reset or resume production, resulting in unplanned downtime.
Electrical, input, test-output and POINTBus data from the Rockwell Automation POINT I/O selection guide.
| Maximum POINTBus current | 125 mA |
| Maximum power dissipation | 3.0 W |
| Typical power dissipation | 2.25 W |
| Maximum thermal dissipation | 10.25 BTU/hr |
| Isolation voltage | 50V continuous, basic insulation between field side and system |
| Channel-to-channel isolation | None |
| Nominal power bus supply | 24V DC |
| Power bus operating range | 19.2–28.8V DC, SELV/PELV 150VA max |
| Power bus current, maximum, no load | 25 mA |
| On-state input voltage at 40°C | 11–30V DC |
| On-state input voltage at 55°C | 11–28.8V DC |
| On-state input current | 3.5 mA |
| Off-state input voltage, maximum | 5V DC |
| On-state input current, minimum | 3.3 mA |
| Off-state current, maximum | 1.3 mA |
| IEC 61131-2 input type | Type 3 |
| Reaction time | Less than 16.2 ms |
| Input filter time | 0–126 ms, in 6 ms increments |
| Number of test outputs | 4 |
| Output type | Current sourcing |
| Test output function | Short-circuit detection for safety input wiring |
| Pulse width | 525 µs |
| Pulse period | 144 ms |
| Maximum permitted field capacitance per test output | 100 nF |
| Short-circuit protection | Yes |
Rockwell identifies 1734-AENT (firmware revision 3 or later) and 1734-AENTR for EtherNet/IP architectures, and 1734-PDN for DeviceNet architectures. The manual lists 1734-ADN, 1734-ADNX, 1734-APB and 1734-ACNR as incompatible adapters for POINT Guard I/O safety communications. Confirm the installed adapter, controller, firmware and safety configuration before replacement.
The manual describes single-channel use up to PLd / SIL CL2 when the channel is configured for Safety Pulse Test.
The manual describes dual-channel use up to PLe / SIL CL3 and Category 3 or 4 when both channels use Safety Pulse Test configuration.
When an input error is detected, safety input data remains OFF. The documented recovery sequence is to remove the error cause, place the safety input into its safe state, and allow the input-error latch time to elapse. The red I/O indicator turns off after the recovery conditions are met.
Safety ratings are conditional on the specified channel configuration and the complete safety system. They are not a standalone guarantee of machine-level performance.
Rockwell's product listing specifies compatibility with terminal bases having eight terminations.
Check wiring, module configuration, firmware revision, safety network addressing and trial operation before returning the system to service.
The manufacturer's manual identifies emergency-stop push buttons, gate switches and safety light curtains as examples of safety devices.
Yes. Its documented input modes include single-channel and dual-channel configurations. The applicable safety rating depends on the configuration and complete safety system.
POINT Guard I/O safety communication is documented over EtherNet/IP and DeviceNet through supported network adapters.
Confirm the full catalog number, terminal base, network adapter, controller, firmware, wiring arrangement and safety input configuration before installation and commissioning.
For engineers searching for a 1734-IB8S pdf/manual/datasheet, the relevant Rockwell Automation publications include the POINT Guard I/O Safety Modules User Manual (1734-UM013) and the POINT I/O Modules Selection Guide (1734-SG001).
Additional model references supplied for sourcing inquiries. These products are not represented as compatible replacements for the 1734-IB8S.
| WPE262C23 | 10-A-44-6666-TT | Weidmüller 1709460000 | AZM 161BST2-AS |
| ADN-63-40-A-P-A | Quint-PS-3x400-500AC/24DC/40 | Land DPU230 | Herion 0810100 |
| 3SE2 902-0AA20 | AZM 161 Z ST1-AS | Rexroth Z2S 6A2-64 R900347499 | S1100B075802 |
| CEM-A-LH10K-S3 | MS6-LRP-1/2-D7-A8M-E11-WB 538028 + MS6-FRM-1/2 | HACH 1900C | HACH CDC40105 |
| HACH SENSION156 | IC694CHS392A | IC694ALG223 | IC694ALG223-GL |
| IC694PWR321 | IC200CPUE05-CF | IC693CPU374-DJ | IC693CPU374-BF |
| IC695NIU001 | IC695NIU001-DN | IC693APU301 | IC693APU301M |
| IC200ALG322 | IC200ALG620 | IC695CPU320-GL | IC694BEM331 |
| IC200ALG230 | HACH PHC805 | HACH DR4900 | HACH LQV157 |
| HACH SIP10 | 230V.60V-1.3A | Vertiv PN275691 | 5SP9225-7KC47 |
| FPF-285-F-3-020 | 57.504.0055.0 | A05B-2400-C061 | AZM 161SK-12/12RKA-024 |
| ADN-63-80-KP-APA | HF6587 | 6ES7312-5BE03-0AB0 | ADN-100-50-A-P-A |
| AZM 161 B ST2-AS | 566601 EP63C25 | 1SDA013986R1 | FRK 92/4-300 S |
| 1494F-M2 |
Send the details below for a product inquiry.
| Part Number | Quantity |
| Destination | Required Date |
| Machine / System Model | |
Send your inquiry directly to us