logo
Home > Products > Honeywell Controller >
Honeywell MC-PLAM02 51304362-150 Low Level Analog Input Multiplexer Processor – 32-Channel

Honeywell MC-PLAM02 51304362-150 Low Level Analog Input Multiplexer Processor – 32-Channel

Honeywell MC-PLAM02 analog input processor

32-channel low level multiplexer

Honeywell controller analog multiplexer

Place of Origin:

USA

Brand Name:

Honeywell

Contact Us
Request A Quote
Product Details
Highlight:

Honeywell MC-PLAM02 analog input processor

,

32-channel low level multiplexer

,

Honeywell controller analog multiplexer

Payment & Shipping Terms
Minimum Order Quantity
1
Packaging Details
Brand new and original
Delivery Time
2-3 work days
Payment Terms
T/T
Supply Ability
in Stock
Product Description
AMIKON INDUSTRIAL SUPPLY

Honeywell MC-PLAM02

51304362-150
Low Level Analog Input Multiplexer Processor
Honeywell MC-PLAM02 51304362-150 product image

ENGINEERING DATA

Technical Specifications

Honeywell TPS Process Manager I/O · IO03-500

TECHNICAL DATA  ·  EXPAND / COLLAPSE
CORE DATA
Input & Conversion
I/O Processor Type Low Level Analog Input Multiplexer (LLMux)
Input Channels 32 galvanically isolated
Input Signal Types Thermocouples, RTDs and linear millivolt signals
A/D Resolution 14 bits
Input Scan Rate 32 samples per second; each channel once per second
FTA Models MU-TAMR03, MU-TAMT03, MU-TAMT13
Input Impedance 2 MΩ minimum at 100 mV
Maximum Normal-Mode Continuous Input -1 V to 10 V, no damage
Voltage Input Range 0 to 100 mV
Line-Frequency Synchronization Configurable to 50 or 60 Hz
Thermocouple & Voltage Input Ranges
Type Normal Range Extended Range
J -100 to 750°C -200 to 1200°C
K 0 to 1100°C -200 to 1370°C
E -150 to 500°C -200 to 1000°C
T -200 to 300°C -230 to 400°C
B +600 to 1650°C +100 to 1820°C
S +550 to 1500°C 0 to 1700°C
R +550 to 1500°C 0 to 1700°C
Japan Type R +550 to 1500°C 0 to 1700°C
Voltage 0 to 100 mV
SUPPLEMENTARY DATA
Electrical & Performance
Common-Mode Voltage 250 VAC peak or ±250 VDC, DC to 60 Hz
Dielectric Strength 1500 VAC rms or ±1500 VDC channel-to-channel during operation; channel-to-PM/APM/HPM common when not operating
Crosstalk 120 dB, DC to 60 Hz
TC / Voltage CMRR 120 dB minimum, DC to 60 Hz, with 500 Ω lead imbalance
NMRR at Line Frequency 60 dB minimum at 50 or 60 Hz
Normal-Mode Filter Response -3 dB point: 5.1 Hz typical; 4.3 Hz minimum; 6.4 Hz maximum
Hardware Reference Junction Accuracy ±1.0°C maximum at 23.5°C ±2°C, in cabinet
Temperature Stability 20 ppm/°C RSS; 30 ppm/°C maximum for voltage, current and thermocouple input except reference junction
Maximum TC Lead Length 16 AWG: 3500 ft; 18 AWG: 2250 ft; 20 AWG: 1250 ft, at 250 V peak/DC common mode
Hardware-Only Accuracy ±40 µV or ±160 mΩ at 23.5°C ±2°C
Software-Only Accuracy ±0.1°C typical; ±0.5°C maximum at 23.5°C ±2°C
Surge Withstand Capability Common mode, ANSI/IEEE C37.90.1-1978
RTD Input Data
RTD Configuration 3-wire
Pt 100 Ω DIN (4376) -200 to 850°C
Pt 100 Ω JIS (C-1604) -200 to 650°C
Ni 120 Ω Ed #7 -45 to 315°C
Cu 10 Ω -20 to 250°C
RTD CMRR, DC to 60 Hz 10 Ω RTD: 120 dB minimum; 100 Ω RTD: 110 dB minimum
RTD NMRR at Line Frequency 10 Ω: 60 dB minimum for 0–15 mV noise; 100 Ω: 60 dB minimum for 0–75 mV noise
RTD Temperature Stability 30 ppm/°C RSS; 40 ppm/°C maximum
Maximum RTD Lead Resistance 15 Ω
Note: Software accuracy refers to software engineering-unit conversion, including software reference-junction compensation, at reference temperature. The manufacturer's specification also identifies mercury-wetted relays in this product.
Source: Honeywell TPS Process Manager I/O Specification and Technical Data · IO03-500 · 11/97
FIELD APPLICATION

Application & Failure Scenarios

01   System Role

Used in Honeywell Process Manager, Advanced Process Manager and High Performance Process Manager I/O installations for low-level process measurement acquisition.

02   Typical Search Triggers

Maintenance teams may search for this processor after missing input readings, unstable measurement values, suspected I/O processor faults or during planned cabinet maintenance.

03   Downtime Considerations

Lost or unreliable measurement data can reduce process visibility and affect decisions based on field readings, extending fault isolation and delaying equipment or process recovery.

MAINTENANCE NOTE

Replacement Verification

Before replacement, verify the complete part number, installed FTA model, field signal types, channel assignment and applicable controller documentation. Confirm the cabinet configuration before removing or installing the processor; do not assume another multiplexer model is a direct replacement.

AMIKON INDUSTRIAL SUPPLY

Industrial Parts Supply, Made Simple.

AMIKON supports industrial maintenance and procurement teams with automation parts sourcing, order coordination and shipment preparation. We focus on accurate part identification and clear communication throughout the purchasing process.

AMIKON industrial automation parts sourcing and service

SALES CONTACT
Miya Zheng
✎ EMAIL
✎ WHATSAPP
PRODUCT QUESTIONS

Frequently Asked Questions

1. What is the Honeywell MC-PLAM02 used for?

It is a low-level analog input multiplexer processor in the Honeywell TPS Process Manager I/O family, intended for acquiring thermocouple, RTD and linear millivolt signals.

2. Which field termination assemblies are listed for this processor?

Honeywell's IO03-500 specification lists MU-TAMR03, MU-TAMT03 and MU-TAMT13. Confirm the installed assembly and system revision before ordering.

3. Is MC-PLAM02 a conformally coated version?

Yes. Honeywell's model-number table identifies MC model numbers as conformally coated boards.

4. What information should I provide when requesting a quotation?

Please provide Part Number, Quantity, Destination, Required Date and Machine/System Model. Contact AMIKON at sales@amikon.cn or WhatsApp +86 180 2077 6792.

5. What are the inspection, delivery and warranty arrangements?

Item condition and agreed testing scope are reviewed before shipment, with protective packaging arranged for transport. Returns and DOA cases are handled according to item condition and agreed sales terms. A 12-month warranty is subject to the quotation terms.

RELATED MODELS   +ADDITIONAL INDUSTRIAL PART NUMBERS

Reference list only. These items are not represented as compatible replacements for the current model.

Model Model Model Model
Siemens 1FK6060-6AF71-1ZGO-Z 8B0P0220HW00.001-1 X20D06529 KH57/R CM71M/BR/TF/AS1H/KK
KH77B CT100LS4/BMG/HF/TF/ES1S IC200CHS002L X20S14100 M55BP132L045F0ELC
Busch SV 1010C000HZZZ NXS00385A5H1SSSA1A3000000 3IF671.9 ABB ACS800-01-0030-3+E202+K454+L503
1PV2V3-32/63RA01MS63A1 X20AO2632 K613SG0170MQ40 SEW KH47 CMP71M/KY/AK1H/SM1
X20D02649 5AP1120.121E-000 X20IF1053-1 A2FE56/61W-ZVL029 R902235161
Indramat MAC112D-0-FD-3-C/130-A-2/S013 IC694MDL231 5AP920.1505-K16 MAC112C-0-HD-4-C/130-A-0/WI520LV
IC200ALG260 IC695PNC001-AK A06B-0352-B731 X20A02632
KEB F4 20F4F3R-4R11 ABB ACS800-01-0030-3+D150+E202+K454+L503+N661+P901 ABB ACS800-04-0035-3+E202+J400+K45+L509+N651+P901 EGC-120-600-TB-KF-0H-GK
AC132 X20IF10E1-1 8507.02 F-RV/400/XF/WK/WTX/S51/SA X20DC1396
7D0135.70 Brevini ED2010 B2001952 Mettler Toledo SWC415 30295854 IC698CPE020
IC694ALG221 Sartorius WZA523-N YAC01ED Siemens 6QG3215-2EA00 IC694MDL930D
IC200CHS005 IC695PNS001-BBBB X20D04623 Indramat MAC112D-0-ED-C/130-A-1/WI565/S05
MDFKABS100-22 X20D08322 SK672.1-112MP/4 TF MDD112C-N-020-N2L-130PAO
IC695HSC304-FA SA87/T AMS132S/M IC200MDL650 NXS00455A2T1SSSA1A3000000
IC697ALG320J IC200PBI001-MH 8B0F0550H000.000-1 IC694MDL240
Steimel SF 2/6 G-VLFM 6APE80M-6-FK/IL Stöber SDS4000 SDS4141 IF622 X20DO6639
IC694MDL930 Siemens 6SC6101-2A-Z 8BAC0121.000-1 X20D08331
ABB ACS800-01-0030-3+E202+K454+L503 MAC112C-0-HD-4-C/130-A-0/WI520LV X20D04623 8B0P0220HW00.001-1
DOCUMENT REFERENCE
Honeywell TPS Process Manager I/O Specification and Technical Data · IO03-500 · 11/97
AMIKON INDUSTRIAL SUPPLY   |   INDUSTRIAL AUTOMATION PARTS SOURCING