AMIKON LIMITED
We'll get back to you as soon as possible.
Place of Origin:
Germany
Brand Name:
Siemens
| Parameter | Specification |
|---|---|
| Model | 353D4F1NNETNNA4 |
| Controller family | Moore 353 Process Automation Controller |
| Power input | 24 VDC, +20%, -15% |
| Case configuration | 52 terminals, gray or green direct-entry connectors, Ethernet connector |
| Display assembly | Fixed analog and digital displays |
| I/O expansion | Local I/O expander |
| Remote I/O communication option | Not required |
| Network communication | Ethernet |
| RTC / configuration backup | RTC/configuration backup board |
| Design level | A |
| Electrical approval code | 4 – FM/CSA Division 2, Class I, Groups A, B, C & D; non-incendive, CE compliant |
| Controller configuration | Function-block based configuration |
| Manufacturer manual | UM353-1, Revision 11, March 2003 |
Confirm electrical approval markings against the actual controller nameplate. Field-added circuit boards may not be reflected on the original nameplate.
The controller uses function blocks arranged in control loops. Configuration can be performed through the local faceplate or supported remote configuration tools.
The manufacturer manual covers installation, electrical wiring, Ethernet connection, controller testing, troubleshooting, error codes, board replacement and calibration procedures.
Before replacement, compare the existing unit's complete designation, terminal arrangement, installed option boards, firmware requirements and approval markings with the proposed unit.
Supporting industrial maintenance and procurement teams with sourcing assistance for automation controllers, drives, electrical components and hard-to-find replacement parts.
Include these details for an accurate inquiry:
Additional models from the supplied reference list. These are sourcing references only and do not indicate compatibility.
| Model | Model | Model | Model |
|---|---|---|---|
| 6EP1337-3BA00 | 6RA8031-6DV62-0AA0 | Siemens 1FT7105-1AC71-1DH1 | Gardner Denver G-BH12BH1640-7HH16 |
| 6EP1437-2BA00 | 6GK5788-1FC00-0AA0 | Siemens 1FT6105-8AC71-4AB1 | Siemens 1LE1001-1DB22-2MB4-Z |
| 6RA7081-6DV62-0-Z-G95+K00+K01 | 6RA8078-6DV62-0AA0 | Blum novotest 142821 IF59-A2 | Festo EGC-HD-220-400-TB-0H-GK |
| 6RA7028-6DV62-0-Z-G95+K00+K01 | 6SE7013-0EP50-Z | Siemens 1FG1502-5RE23-2AJ1-Z | SAH0275-0150 |
| 22-33-39-05-BX | SEW BSHF 802B CM90M/KTY/AS1H/SM50 | Siemens 1GL5114-0GL46-4FU7-Z | SEW EURODRIVE FH67/G DRN100LS4/BE5/TH |
| K3G630-PC12-XB | Tox Pressotechnik PHKL 008.060.002 | Siemens 1FG1502-6UD26-2HN1-Z | Wilo IL100/160-2.2/4 QSFA100L4A-90N |
| YASKAWA SGMGH-30Q5A6C | USM4-14-4-22IB2-9LG | FG3-120/A | MAF100D-0100-FR-S2-AH0-05-N1 R911323397 |
| Siemens 1AV3130B 1LE10231CB035AB4 | MCLTPB03705A3410 | Siemens 1AV3164B 1LE10031DB422AB4-Z | Siemens 1FK7083-2AF71-1CH1-Z |
| Siemens 1AV3131A 1LE10031CA190JB4-Z | Siemens 1AV3131A 1LE10231CA134FA4 | Lenze MCA 21X25-RS0P1-Z0H0-ST6S00N-R0SU | RD51.1-8C-030-L-V1-FW R911201410 |
| Siemens 6RA2281-6GV62-0 + 6RA8232-1KB0 | ABB ACH580-01-062A-4+B056 | SEW K87 DT90L4/BMG/TH | FC-202P22KT4E20H2XGXXXXSXXXXA0BXCXXXXD0 |
| 6AV7894-0BH10-0AB0 | VTI040 890.47.05C | Siemens 2KJ3510-5HA01-0HG2-Z | SK572.1-132MP/4 |
| DRE90M4BE2 | SEW MDV60A0450-503-4-0T | SEW PSF722 CM90L/KTY/VR/AK1H/SM50 | MDD112D-N-020-N2M-130PA1 |
| Mathis Turby T 796 25-17453 | AUMA SA 07.1-SA 48.1/SAR 07.1-F10 | 572.1-132MP/4 | FC-102P30KT4E21H1XGXXXXSXXXXA0BXCXXXXD0 |
| Siemens 2KJ3503-5GJ23-4DF1-Z | Siemens 2KJ3104-1GJ23-4AG1-Z | ABB PSTB840-690-70 1SFA895019R7000 | SA-C57 |
| 45-D2-0940-20-27.5-G1-V3-SW-ST-GP | EGC-HD-160-1250-TB-OH-GK | 572.1-132SP/4 | Siemens 1FK7086-4CF71-1RH0 |
| Afag PDZ-160-1800 50245033-1800-x-x-x | SEW K67 DRN100LS4/TF | 8.01B/MM-1WI420.S | IC695CPE330-ABAF |
| IC694ALG392 | 6SL3330-7TE35-0AA3 | 6RA7078-6DV62-0-Z | SEW Eurodrive MCLTPB03705A3410 |
It is a Moore 353 Process Automation Controller configured with a 24 VDC power input, fixed analog and digital displays, local I/O expansion and Ethernet communication.
Yes. Its ordering designation identifies Ethernet network communication and a case with an Ethernet connector.
The D power-input code specifies 24 VDC with a tolerance of +20% and -15%. Verify the controller label before applying power.
Check the complete model designation, nameplate approvals, terminal arrangement, installed option boards, firmware and existing configuration.
The Siemens Moore 353 User’s Manual, UM353-1, covers configuration, installation, wiring, controller testing, maintenance, troubleshooting and specifications.
Send your inquiry directly to us