ICS TRIPLEX T3481A 16-Channel Guarded Output Module

ICS TRIPLEX T3481A 16-Channel Guarded Output Module

T3481A REGENT CONTROL

T3481A 16-Channel

T3481A Guarded Output Module

Place of Origin:

USA

Brand Name:

ICS Triplex

Model Number:

T3481A

Contact Us
Request A Quote
Product Details
Highlight:

T3481A REGENT CONTROL

,

T3481A 16-Channel

,

T3481A Guarded Output Module

Payment & Shipping Terms
Minimum Order Quantity
1
Packaging Details
Brand new and original
Delivery Time
2-3 work days
Payment Terms
T/T
Supply Ability
in Stock
Product Description
ICS TRIPLEX / REGENT CONTROL SYSTEM
MONITORED GUARDED OUTPUT
T3481A

16-Channel Guarded Output Module
REGENT SERIES · INDUSTRIAL CONTROL
16
OUTPUT CHANNELS
A monitored guarded output module designed for use in the ICS Regent control system.
01 / PRODUCT OVERVIEW
Output control with built-in supervision.
The T3481A provides 16 guarded output circuits, arranged in two groups of eight, with monitoring functions for field wiring and output circuit operation.
16
Output circuits
2 × 8
Circuit groups
Monitored Guarded Output
Field wiring supervision and guarded switching architecture.
02 / CHANNEL ARCHITECTURE
Two groups.
One module.
The 16 output circuits are divided into two groups. Each group contains eight circuits and has separate field power connections.
T3481A

GROUP 1
01–08
8 circuits
GROUP 2
09–16
8 circuits
SEPARATE FIELD POWER CONNECTIONS
03 / GUARDED OUTPUT PRINCIPLE
A monitored path to the field load.
The T3481A uses two independent output switches connected in series with the load. This guarded arrangement is designed to prevent a single internal switch fault from inadvertently energizing the field output.
CONTROL
COMMAND
› SERIES
SWITCHES
› FIELD
LOAD
Automatic testing checks output circuit operation and helps detect stuck-on or stuck-off switch conditions.
04 / MONITORING & DIAGNOSTICS
What the module supervises
01
Open-Circuit Detection
Monitors output field wiring for open-circuit conditions that may affect the connected load.
02
Short-Circuit Detection
Provides monitoring for short-circuit conditions in the output field wiring.
03
Automatic Testing
Checks output circuit behavior and helps identify abnormal switch conditions.
04
Front-Panel Indication
Front-panel indicators assist maintenance personnel in checking module and circuit status.
05 / REGENT SYSTEM CONTEXT
Part of the Regent I/O architecture.
The T3481A operates within the ICS Regent control system. Processor commands are communicated over the I/O Safetybus, while the module manages the guarded field output circuits.
REGENT PROCESSOR
↓
I/O SAFETYBUS
↓
T3481A OUTPUT
06 / REPLACEMENT & FIELD CHECKS
Check the application, not just the part number.
01 Confirm the complete T3481A part identification and installed revision.
02 Check the two groups of eight circuits and their separate field power connections.
03 Review load current, off-state leakage and the load's guaranteed-off voltage.
04 Follow the approved site procedure for removal, installation and commissioning.
07 / TECHNICAL FAQ
T3481A — Questions for Maintenance Teams
Q1. How does the T3481A respond to a single internal output-switch fault?
Its two independent output switches are connected in series with the field load. The guarded arrangement is designed so that a single switch fault does not inadvertently energize the output. Automatic testing can detect stuck-on and stuck-off conditions.
Q2. Why can the T3481A detect a wiring fault when the output command is correct?
The module monitors the field wiring as well as output operation. An open or short circuit in the external wiring can therefore be detected independently of the commanded output state.
Q3. What should be considered when connecting T3481A modules in parallel?
Parallel arrangements require modules of the same type and the correct field wiring configuration. Verify the approved system design, group power connections and load arrangement before making changes.
Q4. Can the T3481A operate with very low-current field loads?
Not every low-current load is suitable. Off-state test current can create residual voltage that prevents some devices from turning fully off. Check the load's guaranteed-off voltage and the module's off-state behavior before connection.
Q5. Why do the T3481A's two output groups matter during maintenance?
The 16 circuits are arranged in two groups of eight with separate field power connections. Identifying the correct group before wiring work helps avoid incorrect power and load connections.
Amikon team and industrial automation support

AMIKON INDUSTRIAL SUPPORT
PEOPLE · PARTS · SERVICE
Industrial Parts.  Global Support.

Founded in Hong Kong in 2005, Amikon is a global supplier of industrial automation parts and control system components.
Its product range covers PLC, HMI, DCS, panel controllers, industrial PCs and VFDs, supported by a team focused on hard-to-find parts and complex requirements.
International Delivery on the Day
Quick Response Support
Intercontinental Cooperation Network
08 / CONTACT AMIKON
Looking for T3481A?
Send us your required part number, quantity and destination. Our team is ready to assist with your inquiry.
SALES MANAGER
Miya Zheng
EMAIL
sales@amikon.cn
PHONE / WHATSAPP
+86 180 2077 6792
09 / MORE INDUSTRIAL PARTS
Explore More Popular Models
Browse additional automation components and spare parts.
RCU510 MCS-3000X 1756-IB16IF
API-AMC2-4WE EX-Q 1345 644HAE1J6A1G3
FX106-4-2 ARM55D-000 SM87PBMD
AAP0540089-00217 51304453-150 PR 6211/23
3WL9111-0BA14-0AA0 3KA7141-3AA00 Mcs-si16
HMXBNC128 COSA-4055 456D012058
FVR46(M) CBR24-V MN-S4-500-A
G4514-60610 IC200UEX014-B AMP-330-EUR
CH-HRIO8-D9 CNPCI-8 SDW-532-2SM-SC15
SNT401-53 TSR-44 467NHP81100
499NMS25102 RC-EIO2-MIXT1-D GPS-101-2
G319-T MB-FB-4R CC-12000
9240002-575 82408217-001 MCS-3000X
2212/STBNDP2212

Send your inquiry directly to us