Probe signal conditioningThe Proximitor Sensor powers the compatible proximity probe and converts the probe response into a conditioned voltage proportional to distance from the observed conductive surface.
MONITOR
Static and dynamic outputThe conditioned signal supports shaft-position, vibration and related machinery-monitoring measurements when used as a complete matched 3300 XL 8 mm transducer system.
PRESERVE
Modified executionX1-CN and MOD:143416-29 must remain attached to the full identity. Standard 330180 ordering logic must not overwrite the special modification.
Matched Transducer Loop
3300 XL 8 mm PROBE
→
EXTENSION CABLE
→
330180-X1-CN MOD:143416-29 PROXIMITOR SENSOR
System-length rule: the probe and extension-cable lengths must equal the Proximitor Sensor system length. For this X1 modification, verify the installed loop marking rather than assigning a standard length from appearance.
Identity and Compatibility Check
Manufacturer
Bently Nevada
Product family
3300 XL 8 mm Proximity Transducer System
Complete sensor code
330180-X1-CN
Special modification
143416-29
Approval suffix
CN, country-specific approval execution
Required companions
Compatible 3300 XL 8 mm probe and extension cable forming the approved system length
Installation Acceptance
Loop matchConfirm probe family, extension cable, total system length and complete sensor marking.
Gap setupEstablish the approved mechanical gap and verify the DC bias lies within the site's target operating region.
Signal proofCheck polarity, scale, dynamic response, grounding and monitor-channel behavior before release.
AMIKON SUPPLY SERVICE
Exact-code support for machinery protection
We support urgent automation requirements with complete-code checking, condition confirmation, protective packing and coordinated international delivery.
12-month warrantyContact us within seven days of receipt if an issue appears. Keep the item in its original condition and state the reason. An eligible return or replacement follows inspection; return freight is paid by the buyer.
Why should X1 not be replaced with a guessed standard 330180 length code? X1 is retained with the special modification. Assigning 11, 51 or 91 from appearance can create an incorrect matched length and change the transducer response. Verify the original loop identity first.
02
Can MOD:143416-29 be replaced by another 330180-X1-CN modification? Not without engineering confirmation. Modification numbers can represent execution-specific changes that are not visible externally. Match the complete MOD number or obtain explicit acceptance for the receiving loop.
03
Which field readings best expose a mismatched probe and extension cable? Check DC bias at the established mechanical gap, linear response over a controlled displacement and the monitor scale factor. Abnormal bias, limited linear range or incorrect sensitivity indicates a loop mismatch or wiring fault.
04
Why can a healthy 330180-X1-CN show unstable gap voltage after replacement? Inspect connector seating, extension-cable routing, shield grounding, nearby interference, probe mounting rigidity, target runout and contamination at the probe tip before adjusting the monitor.
05
What should be recorded before removing MOD:143416-29 from service? Record the full label, mounting, probe code, extension-cable code, connector condition, DC gap voltage, monitor scale and observed waveform so the replacement loop can be compared objectively.
Recommended Models
330881-28-04-214-00-02
KJ3243X1-BK1
8I0IF109.400-1
HQ440D
AM3100T2-Z2-00
8C-TCNTA1
330130-075-01-00
ILX69-PBM
3HAC030211-001
R-2000IB/210F
FC-IO-0001
MC-TDIA72 51303930-150
330102-00-12-10-01-05
EP3-E-4-EN
8I0IF248.300-1
51403698-100
ASM46AK-T20
7932-4210
5ACPCI.ETH3-01
2100P
30735974-002
330104-00-08-15-02-00
4PP352.0571-35
X-CPU 31
TL2360
5LS172.6
3HAC047577-002
6ES7214-1BG31-0XB0
146054-34-20-02-05
DC-TCF901 51307593-176
330881-28-04-265-00-02
ISENH3181
330879-03-00
3RW4026-1BB04
81001-450-51-R
6ES7193-6PA00-0AA0
2612602
DC-TFB412 51307618-176
8V1016.00-2
6ES7135-6HB00-0DA1
Request a 330180-X1-CN MOD:143416-29 quotation
Send full label photographs, loop length, quantity, destination and required delivery date.