logo
Home > Products > Honeywell Controller >
Honeywell 900B08-0202 Eight-Channel Analog Output Module

Honeywell 900B08-0202 Eight-Channel Analog Output Module

Honeywell 900B08-0202

900B08-0202 EDGE 900

900B08-0202 Analog Output

Place of Origin:

USA

Brand Name:

Honeywell

Model Number:

900B08-0202

Contact Us
Request A Quote
Product Details
Highlight:

Honeywell 900B08-0202

,

900B08-0202 EDGE 900

,

900B08-0202 Analog Output

Payment & Shipping Terms
Minimum Order Quantity
1
Packaging Details
Brand new and original
Delivery Time
2-3 work days
Payment Terms
T/T
Supply Ability
in Stock
Product Description
CONTROL EDGE 900 PLATFORM
900B08-0202
Eight-Channel Analog Output Module
Eight scalable current outputs for process final-control devices, arranged as two isolated groups of four channels.
8Outputs
0-21.0 mASelectable range
750 ohmsMaximum load
Confirm terminal block, loop-power method and installed revisionSales Manager: Miya Zheng EMAIL WHATSAPP
Controlled Current for Eight Final Elements
SYNCHRONIZED WITH CONTROL EXECUTION
The Honeywell 900B08-0202 delivers eight analog current outputs. Each output can be scaled to a selected span within 0 to 21.0 mA. The module updates its outputs in step with control execution and supports an individual rate-of-change limit where a gradual actuator movement is required. Predictable interruption behaviorA configured failsafe value can be applied if communication between the controller and module is interrupted. This setting must be checked against the required safe position of every connected final element.
1-4Output group A 5-8Output group B 500 VDCGroup-to-group 500 VDCOutputs to logic
PERFORMANCE PROFILE
Analog Output
Feedback confirms that output current is flowing. It does not replace a complete field-loop functional check.
Outputs8; two groups of four
Current range0 to 21.0 mA, selectable
Maximum load750 ohms
Accuracy0.1% full scale at rated conditions
D/A resolution13+ bits; 1 part in 13332
Current sensingGreater than 0.5 mA per output
Size137 x 35.6 mm; 5.4 x 1.4 in
Mass400 g
Loop Power and Termination Decisions

Power selectionA module switch selects internal 24 V backplane power or a separate external loop supply. The factory switch position is external power. External supplyExternal loop power requires 18 to 36 VDC and a capacity of 350 mA per module. Terminal hardwareThe module uses a 36-position Euro-style terminal block. Confirm the installed block and remote termination arrangement before ordering.
Rack-loading check: internal 24 V power changes the permitted module loading. Confirm the installed power arrangement and total rack demand rather than assuming every open slot can accept another analog output module.
AMIKON SUPPLY SERVICE
Industrial Parts Checked for Confident Dispatch

For more than 20 years, AMIKON has supported industrial automation users with responsive part sourcing, condition checks and urgent global delivery.
LABEL CHECKSECURE PACKINGFAST DELIVERY

12-Month WarrantyCondition, coverage and delivery terms are confirmed in the quotation. Return ArrangementContact us within 7 days if an issue is found. Keep the item in its received condition and state the exact reason. After inspection, an approved return can proceed to replacement or refund. Return transport charges are borne by the buyer. Sales ContactSales Manager: Miya Zheng
sales@amikon.cn
+86 180 2077 6792
900B08-0202 Buyer FAQ

Can 900B08-0202 use the rack supply instead of external 24 VDC? Yes. A module switch selects internal or external power, but rack loading must be recalculated before changing the setting. The shipped setting is external power, so never assume a replacement is already configured like the removed module.
Does 500 VDC isolation apply between all eight 900B08-0202 channels? No. Channels 1-4 form one group and channels 5-8 form a second group. The 500 VDC rating applies group-to-group and from the outputs to controller logic; channels inside the same group are not individually isolated.
What can cause a correct current command to fail at the field device? Check loop-power polarity, available supply voltage, total loop resistance, terminal seating and the field device input. The 750-ohm maximum is a loop limit, and available compliance must still cover cable and device voltage drops.
Which settings must be captured before replacing 900B08-0202? Record each channel span, engineering scaling, failsafe value, rate limit, calibration state and internal/external power selection. Also photograph all 36 terminal positions before disconnecting conductors.
Does output-current feedback prove the 900B08-0202 loop is healthy? It confirms that current is flowing, but it cannot prove correct actuator travel, valve direction, scaling or safe action. Commissioning should compare commanded current, measured loop current and actual field response at several operating points.
Recommended Models
INDUSTRIAL AUTOMATION PART NUMBERS
51304584-100 ADV551-P03 S2 1771-WHFB T8310C
900G02-0102 140CPU65150C TC-FXX072 321131-A01
3100-LTQ AAT141-S00 S2 900B01-0101 1785-L20C15
T9310-02 PW482-11 S2 2711P-RN10C 51304159-100
BMXP341000 900H03-0102 2094-AC09-M02 T8122
TC-HAO081 MVI56-AFC AAI143-S00 S1 1746-INT4
51305072-700 170AAO92100 ATK4A-00 S1 315116-A05
T8153C 1771-ACNR15 ADV159-P00 TSX3710001
3100-INUSA R02S02L03 51195096-200 140DDO35300
MVI56-ADMNET ADV161-P00 S2 1336S-BRF10-AA-EN TCSEGDB23F24FA
Check Honeywell 900B08-0202 availability
Send the full label, quantity, terminal-block type, loop-power method and destination.
Sales Manager: Miya Zheng   |   sales@amikon.cn   |   +86 180 2077 6792

Send your inquiry directly to us