Product Description
AMIKON INDUSTRIAL SUPPLY · CONTROL SYSTEMS
ALLEN-BRADLEY / PANELVIEW STANDARD

Allen-Bradley 2711-T10C8
PanelView 1000 Color Touch Terminal

A color touchscreen operator terminal for established DH+ control environments, with a separate RS-232 printer interface and a PanelBuilder32 application workflow.

01 / PRODUCT PROFILE

Operator Interface for Installed DH+ Equipment

The Allen-Bradley 2711-T10C8 is a PanelView Standard 1000 color touchscreen terminal designed for operator interaction in machine and process control systems. It provides a visual interface between plant personnel and a controller operating on a DH+ network.

For maintenance teams working with an established PanelView installation, identifying the exact catalog number is an important first step when checking the terminal, reviewing an existing application or preparing a hardware migration.

PanelView Standard Color Touch Operation DH+ Control Network Legacy HMI Support
02 / APPLICATION & FIELD CONDITIONS

Keeping the Operator Station Available

In an installed control system, the operator terminal provides access to machine screens, operating information and controller-linked commands. A terminal fault can therefore affect the operator's normal interaction with the equipment.

Display or touch fault A blank display, damaged screen or unreliable touch response can prevent operators from viewing status information or entering normal HMI commands.
DH+ communication interruption A communication fault can interrupt the terminal's access to controller data and affect the availability of machine screens.
Terminal hardware failure A terminal that will not start or reports a hardware fault may require inspection, repair assessment or replacement to restore the operator station.

Actual downtime impact depends on the machine operating procedure and the availability of local controls. Check the terminal, network and controller before selecting replacement hardware.

03 / TECHNICAL DATA

Hardware Specifications

A compact parameter reference covering display, memory, communication, electrical, mechanical and environmental details.

IDENTIFICATION · DISPLAY · MEMORY
ManufacturerAllen-Bradley / Rockwell Automation
Product familyPanelView Standard 1000
Catalog number2711-T10C8
Operator inputTouchscreen
Display typeColor active-matrix TFT
Display area211 × 158 mm
(8.3 × 6.2 in.)
Resolution640 × 480 pixels
Touchscreen384 touch cells
Touchscreen actuation1 million presses
BacklightField-replaceable
Backlight half-life50,000 hours at 25 °C
Application runtime memory310 KB
Nonvolatile memory1008 KB for application objects, text and bitmaps
Memory cardATA memory card supported
Application softwarePanelBuilder32
COMMUNICATION · ELECTRICAL
Controller communicationDH+ (Data Highway Plus)
Additional portRS-232 printer port
Input voltage85–264 V AC
Input frequency47–63 Hz
Maximum AC power consumption55 VA
MECHANICAL · ENVIRONMENTAL
Approximate weight3.6 kg (7.9 lb)
Touch version
Approximate dimensions (H × W × D)282 × 370 × 112 mm
(11.11 × 14.58 × 4.40 in.)
Recommended panel cutout257 × 338 mm
(10.11 × 13.29 in.)
Operating temperature0–55 °C (32–131 °F)
PanelView 1000 family specification
Operating vibration2 g up to 2000 Hz
Family specification
Enclosure ratingNEMA Type 12, 13, 4X (indoor use); IEC IP54 / IP65 when properly installed in an equivalently rated enclosure
04 / NETWORK CONNECTION

DH+ Controller Communication

The terminal communicates with supported controllers through a DH+ network. Rockwell Automation's user manual identifies PLC-5, SLC 5/04 and ControlLogix controller connections for this communication environment.

PanelView 1000 2711-T10C8 operator terminal
↔
DH+ Network Controller communication link
PLC-5DH+ link
SLC 5/04DH+ link
ControlLogixDH+ link
Interface distinction: The RS-232 interface is identified as a printer port in the model selection information. It should not be confused with the DH+ controller communication connection.
05 / INSTALLATION & DIAGNOSTICS

Panel Mounting and Field Checks

Correct mounting helps maintain the terminal's panel seal and mechanical stability. The following installation details are useful when inspecting an existing panel or preparing a service replacement.

Mounting clips Install six clips: two at the top, two at the bottom and one on each side.
Mounting torque 1.13 Nm (10 lb-in). Avoid overtightening the mounting clips.
Sealing gasket Position the gasket correctly to form a compression seal. Do not use sealing compounds.
Ventilation Allow adequate enclosure ventilation and account for heat from nearby equipment.
Panel opening reference Use the full-size manufacturer template when preparing the panel opening.
Power isolation Disconnect panel power before installation, removal or service work.
COMM — Green Indicates communication activity.
FAULT — Red Indicates firmware or hardware faults.

Follow the complete manufacturer instructions for wiring, enclosure suitability and hazardous-location requirements.

06 / PRODUCT MIGRATION

Rockwell Automation Listed Migration Option

Rockwell Automation's PanelView migration guide identifies the following primary replacement option for the 2711-T10C8.

PANELVIEW PLUS 7 PERFORMANCE
2711P-T12W22A9P
ADAPTER PLATE
2711P-RAAT12K

The migration guide notes that an adapter plate is necessary for a drop-in replacement. The listed terminal has a different display resolution and Ethernet communication. Application migration, communication changes and panel-fit verification are therefore required. This is a documented migration option, not a claim of direct electrical or application compatibility.

AMIKON INDUSTRIAL SUPPLY
AMIKON industrial supply service and parts sourcing
SUPPLY SUPPORT
Identify.
Source.
Keep Moving.
Practical coordination for industrial automation parts.
PRODUCT ENQUIRY & SOURCING SUPPORT
Miya Zheng
EMAIL / SALES ENQUIRY
WHATSAPP / DIRECT CONTACT
Share the catalog number and application details with your enquiry. AMIKON can coordinate product identification, availability checks, quotation details and shipment arrangements according to the order requirements.
07 / ORDER & DELIVERY SUPPORT

Order Preparation and After-Sales Support

Pre-dispatch checks Part-number and nameplate verification, visual condition inspection and functional checks where the available test setup permits. Test scope can be confirmed with the quotation.
Protective packaging Protective packaging suitable for transport and handling, with attention to the condition of the supplied industrial component.
DOA / Returns Report suspected dead-on-arrival or transit damage promptly with product, packaging and fault evidence. Return arrangements require AMIKON authorization and assessment.
Warranty 12-month warranty, subject to quotation terms. Coverage and exclusions are confirmed with the order.
RFQ details to provide: Part Number · Quantity · Destination · Required Date · Machine/System Model.
08 / MODEL-SPECIFIC FAQ

Frequently Asked Questions

1. What communication protocol does the 2711-T10C8 use?

It uses DH+ for controller communication. The model selection information also identifies an RS-232 printer port.

2. Which controllers are identified for connection through its DH+ port?

The Rockwell Automation user manual identifies PLC-5, SLC 5/04 and ControlLogix controllers on a DH+ link.

3. Which software is specified for the PanelView Standard 1000?

The PanelView Standard specifications identify PanelBuilder32 software running on a personal computer.

4. What power supply does the 2711-T10C8 require?

The documented AC input range is 85–264 V AC at 47–63 Hz, with maximum AC power consumption of 55 VA.

5. Is the 2711P-T12W22A9P a listed migration option?

Yes. Rockwell Automation lists it as a primary replacement option for the 2711-T10C8 and identifies adapter plate 2711P-RAAT12K. It is a migration option rather than a direct drop-in equivalent without panel and application checks.

Documentation reference: For 2711-T10C8 PDF, manual and datasheet research, consult the Rockwell Automation PanelView Standard Operator Terminals User Manual and PanelView Standard Terminal Specifications.
09 / AMIKON PART NUMBER INDEX

Related Models

Additional part numbers from the supplied sourcing reference pool. These are sourcing references only and are not represented as compatible replacements for the 2711-T10C8.