Product Description
Allen-Bradley · ControlLogix Communication

1756-DHRIO

ControlLogix Data Highway Plus / Remote I/O Communication Module. Designed to connect DH+ networks and remote I/O devices with ControlLogix-based control systems.

Data Highway Plus Remote I/O Scanner Two Communication Channels ControlLogix
Communication Interface DH+ messaging · CIP messaging · Remote I/O scanning Product Status Discontinued by Rockwell Automation on December 31, 2024
01

Product Overview

The Allen-Bradley 1756-DHRIO is a ControlLogix communication interface for Data Highway Plus (DH+) and Remote I/O networks. It supports communication between ControlLogix controllers and PLC or SLC devices across supported networks. When a channel is configured for Remote I/O, the module operates as a scanner and exchanges discrete and block-transfer data with remote I/O devices.

DH+ Network Communication

Provides DH+ messaging and routing between devices on DH+ networks and other supported networks, including Ethernet and ControlNet paths through the ControlLogix system.

Remote I/O Scanning

Acts as a Remote I/O scanner, exchanging I/O data with remote adapters and allowing the ControlLogix controller to communicate with remote I/O devices.

02

Technical Specifications

Manufacturer
Allen-Bradley / Rockwell Automation
Model
1756-DHRIO
Product Family
ControlLogix
Product Description
Data Highway Plus / Remote I/O Communication Interface Module
Communication
Data Highway Plus (DH+) / Remote I/O (RIO)
Number of Channels
2 — Channel A and Channel B
Communication Functions
DH+ messaging, CIP messaging and Remote I/O scanning
Channel A DH+ Rates
57.6 Kbps, 115.2 Kbps and 230.4 Kbps
Channel B DH+ Rates
57.6 Kbps and 115.2 Kbps
230.4 Kbps Operation
Available on Channel A only; Channel B is disabled in this mode
DH+ Node Address
00–77, set and displayed in octal
Remote I/O Function
Scanner; transfers discrete and block-transfer data with remote I/O devices
Remote I/O Capacity
32 logical rack connections per channel or 16 block-transfer connections per channel
Front Connections
Channel A connector, Channel B connector and 8-pin Mini-DIN programming terminal
Backplane Interface
ControlLogix chassis backplane
Product Lifecycle
Discontinued December 31, 2024
Channel configuration and supported communication rates depend on the selected network mode. In 230.4 Kbps DH+ mode, Channel B is disabled. Confirm the module series, firmware revision, chassis configuration and network requirements before replacement or commissioning.
Additional Technical and Configuration Details
Channel Network Modes
DH+ or Remote I/O scanner
DH+ Switch Selection
Channel A: 57.6K / 115K / 230K; Channel B: 57.6K / 115K
Remote I/O Switch Selection
RIO scanner mode on either channel
Remote I/O RPI
Configurable from 2 to 750 ms in the module configuration
Programming Terminal
8-pin Mini-DIN connection
DH+ Cable Reference
Belden 9463 twinaxial cable
Programming Cable References
1784-CP for nonhazardous applications; 1784-U2DHP for hazardous-location programming connection requirements described in the manual
Status Indication
Alphanumeric status display, channel status indicators and module OK indicator
DH+ Node Address Setting
Node address switches are used for DH+ mode and do not apply to Remote I/O mode
03

System Applications & Fault Scenarios

The 1756-DHRIO is used in ControlLogix systems that need to retain or bridge communication with existing DH+ networks and Remote I/O installations. It is relevant to plants integrating legacy PLC-5 or SLC controllers, remote I/O adapters and ControlLogix-based control equipment.

Communication Loss

DH+ Network Interruption

When PLC or SLC devices become unreachable through a DH+ link, maintenance teams may inspect the communication path, node addressing, routing configuration and DHRIO interface.

Remote I/O Fault

Scanner or Adapter Offline

If remote I/O data stops updating or an adapter is not detected, the scanner channel, network wiring, adapter status and scan-list configuration may require investigation.

Production Risk

Control Data Unavailable

Communication faults can interrupt controller-to-device data exchange, affecting machine sequences, remote I/O control and production coordination. The resulting downtime depends on the system architecture and affected process.

04

Installation, Configuration & Diagnostics

Chassis Installation

The module is installed in a ControlLogix chassis. Align the circuit board with the chassis guides and ensure that the backplane connector is properly seated. When replacing an identical module and restoring the same system operation, the manual specifies installation in the same slot.

Network Setup

Set the channel network type and, for DH+ operation, the applicable node address. Configure the routing table and channel settings according to the network design and controller application.

Useful Status Messages for Troubleshooting
OFF LINE
The DH+ link is in STOP state; check network configuration and link operation.
DUPL NODE
Duplicate DH+ node address; select another node address and reset the switches.
ONLY NODE
Only one node is detected on the DH+ link; check network cables and connected devices.
CNFG FAULT
Check the DH+ routing table, DH+ object configuration and module slot placement.
A OK / B OK
Channel status indication for normal operation on the respective channel.
SCAN
Indicates Remote I/O scanner operation.
Before connecting or disconnecting communication cables, follow the manufacturer's safety instructions. The manual warns of electrical arcing when communication cables are handled with power applied. Use suitable ESD precautions when handling the module.
05

Product Lifecycle & Sourcing

Rockwell Automation lists the 1756-DHRIO as discontinued, with a discontinuation date of December 31, 2024. The product page identifies its replacement category as Engineering Replacement. A specific direct replacement should not be assumed from that category alone; confirm the required network functions, channel configuration, controller platform and application requirements before selecting an alternative.

AMIKON supports sourcing requests for the 1756-DHRIO. Please provide the full catalog number and, where possible, the module series and application details so the requested item can be checked against your system requirements.

06

About AMIKON Industrial Supply

AMIKON Industrial Supply supports industrial automation parts sourcing for maintenance teams, system integrators and equipment operators. Our focus is practical product identification, order coordination and communication throughout the sourcing process.

For discontinued control-system components such as the 1756-DHRIO, sharing the existing part number, equipment details and application requirements helps us understand the sourcing request more accurately.

Miya Zheng Email · Direct Inquiry sales@amikon.cn WhatsApp · Quick Contact +86 180 2077 6792
AMIKON industrial automation sourcing service
AMIKON industrial parts service detail
AMIKON Industrial Supply · Practical Sourcing Support
07

Delivery, Testing & Warranty

Inspection & Testing  Order-specific inspection and testing arrangements can be confirmed with the quotation.
Protective Packaging  Suitable protective packaging for industrial parts during shipment.
Warranty  12-month warranty, subject to the agreed quotation terms and coverage.
Returns & DOA  Report transit damage, incorrect supply or DOA concerns promptly with photos and order details for review.
RFQ Information: Please include Part Number · Quantity · Destination · Required Date · Machine/System Model.
08

Frequently Asked Questions

01How many communication channels does the 1756-DHRIO have?

It has two channels, Channel A and Channel B. Each channel can be configured for DH+ or Remote I/O operation, subject to the documented channel limitations.

02Can both channels operate at 230.4 Kbps DH+?

No. The 230.4 Kbps DH+ setting is supported on Channel A only. When Channel A is configured for 230.4 Kbps DH+, Channel B is disabled.

03What should be checked when a DH+ device or Remote I/O adapter goes offline?

Check the module display and channel status, network cabling, node address, channel mode, routing table and remote adapter configuration. The displayed status message can help narrow down the fault.