AMIKON Industrial Supply   /   Bently Nevada

21505-00-44-10-02 Proximity Probe

21505-00-44-10-02

An 8 mm probe configuration within the Bently Nevada 7200 proximity transducer family, intended for non-contact displacement measurement as part of a compatible probe, extension-cable and Proximitor arrangement.

01   PROBE IDENTIFICATION 02   SYSTEM PERFORMANCE 03   MAINTENANCE SUPPORT

Technical Specifications

The 7200 family uses an eddy-current measurement principle. The figures in the performance column describe the family-level system, not a guarantee of standalone probe performance outside a correctly matched assembly.

Product identification
Part number 21505-00-44-10-02
Manufacturer Bently Nevada
Product type Proximity probe
Product series 7200 Series, 5 mm / 8 mm proximity transducer system
Probe family diameter 8 mm
Measurement principle Eddy-current, non-contact displacement measurement
Additional 7200 system specifications
Linear measurement range 2.03 mm (80 mil), system calibration range
Average scale factor Typical: 7.87 ± 0.21 V/mm (200 ± 5.4 mV/mil) at 22°C
Average scale factor, worst case 7.87 ± 0.39 V/mm (200 ± 10 mV/mil)
Gap at −3.0 V 0.508 ± 0.254 mm (20 ± 10 mil)
Proximitor supply range −17.5 to −26 VDC; barrier arrangements have separate supply requirements
Current draw 12 mA maximum with a 10 kΩ load
Output resistance 50 Ω
Output load used for calibration 10 kΩ resistive load
System calibration target AISI E4140 steel
System test conditions 22°C, −24.0 ± 0.1 VDC supply and 10 kΩ load
Probe construction and mechanical limits
Probe case material 300-series stainless steel
Lead and core jacket PTFE (Teflon)
Probe connector materials Stainless steel and silver-plated brass with PTFE dielectric insert
Probe coil resistance, nominal 3.3 Ω
Case-to-circuit isolation Designed to withstand at least 500 VAC at 60 Hz with less than 1 mA current flow
Minimum recommended cable bend radius 25.4 mm (1.0 in) for armored and unarmored cables
Probe case torque Depends on case thread and mounting style; use the applicable probe specification

Mechanical data above describes the 7200 probe family. Do not apply a generic torque value without identifying the exact mounting and thread configuration.

How the Measurement System Works

The probe is one part of a measurement chain. The probe, extension cable and Proximitor must be selected and installed as a compatible system.

01 / SENSING
Probe tip Creates an electromagnetic field at the conductive target surface.
02 / TRANSMISSION
Extension cable Connects the probe lead to the signal-conditioning unit within the specified system length.
03 / CONVERSION
Proximitor sensor Converts changes in the returned signal into an output voltage related to probe-to-target gap.
04 / MONITORING
Monitoring channel Receives the signal for machinery displacement or vibration monitoring.

Typical measurement applications include shaft position and vibration monitoring on rotating or reciprocating machinery, such as turbines, compressors, pumps, motors and generators.

Fault Diagnosis & Maintenance

When a monitoring channel reports an abnormal signal, investigate the complete transducer path instead of replacing the probe based on the symptom alone.

Observed condition Possible cause Diagnostic direction
Monitor OK indication absent Power supply, field wiring, transducer circuit or incorrect probe gap Check the system supply, field connections and probe-to-target position before isolating individual components.
Transducer supply outside expected range Faulty supply, field wiring or Proximitor Compare the source voltage with the voltage measured at the transducer, then isolate the supply and wiring path.
Signal output at 0 VDC Incorrect supply, shorted field wiring or a faulty Proximitor Check supply conditions and shorts in the field wiring or terminal connections.
Signal between −1 VDC and 0 VDC Probe too close to target, incorrect target surface, connector fault or an open/short circuit Check probe gap and target geometry; inspect connections and test the probe and extension cable as separate components.
Unexpected change in trend Possible transducer fault or a genuine change in machinery condition Compare the signal with historical trends and machine operating conditions before concluding that the probe has failed.
After component replacementVerify system performance when a probe, cable or Proximitor is replaced, remounted or appears damaged.
Connection integrityInspect coaxial connectors for looseness, contamination, moisture or damage before testing.
Grounding and safetyFollow the applicable installation and hazardous-area procedures. Probe cases require a solid earth-ground connection where specified.
Maintenance test equipment and measurement references
Test equipment Digital multimeter, spindle micrometer, 10 kΩ fixed resistor and a −24 VDC ± 1 V supply for the described scale-factor verification setup
VPS Power-source voltage measured between the power source and common
VXDCR Voltage at the transducer measured between −VT and COM
VSIG Signal voltage measured between OUT and COM
System cable resistance reference The manual gives nominal total resistance checks for 5 m and 9 m system arrangements; use the relevant system configuration and full troubleshooting procedure when testing.

These checks require qualified personnel and suitable test arrangements. Isolate hazards and follow the site's machinery-protection and electrical safety procedures before troubleshooting.

Application & Downtime Considerations

Machinery monitoring Used within compatible proximity transducer systems for non-contact shaft displacement and vibration measurement.
Typical sourcing trigger A failed monitoring channel, damaged probe lead, connector problem or maintenance finding may prompt a search for the exact replacement part.
Operational consequence An unavailable or unreliable measurement channel can complicate condition assessment and delay maintenance decisions or equipment return to service.

Delivery, Warranty & RFQ

Pre-shipmentPart-number and visible-condition checks; inspection photos may be requested.
PackagingProtective packing is arranged according to the order and shipment requirements.
DOA / ReturnsReport arrival defects promptly with order details and supporting photos or video. Return approval follows agreed sales terms.
Warranty12 months, subject to the quotation terms and written coverage conditions.

For a quotation, provide the following details:

Part NumberExact part number and suffix
QuantityRequired quantity
DestinationShip-to location
Required DateTarget delivery date
Machine/System ModelInstalled equipment details
AMIKON Industrial Supply

Clear part-number communication, sourcing coordination and quotation support for industrial automation and machinery-monitoring components.

Miya Zheng
Email / Sales Enquiries
WhatsApp
INDUSTRIAL PARTS   /   SOURCING   /   ORDER SUPPORT
AMIKON industrial service and sourcing team
INDUSTRIAL SERVICE
Industrial components and sourcing support
PARTS SOURCING

Frequently Asked Questions

1. What is the 21505-00-44-10-02?

It is identified as a Bently Nevada 7200-series proximity probe in the 8 mm product family.

2. What does the 7200 system measure?

The system measures the gap between the probe tip and a conductive target, supporting non-contact displacement and vibration measurement.

3. Can this probe be mixed with another proximity system series?

Do not assume cross-series compatibility. Match the probe, extension cable, Proximitor and monitoring arrangement to the applicable system specification.

4. What should be checked when the monitoring output becomes abnormal?

Check supply voltage, field wiring, connector integrity, probe gap and target conditions before identifying a failed component.

5. How do I request the 21505-00-44-10-02 PDF/manual and a quotation?

Email sales@amikon.cn with the full part number, quantity, destination, required date and machine/system model to request sourcing and documentation assistance.

21505-00-44-10-02 PDF / Manual

For engineering evaluation and maintenance, refer to the Bently Nevada 7200 Series 5 mm / 8 mm Proximitor Sensor Supplement Manual, Part Number 164931-01, together with the applicable 7200 proximity probe and system documentation.

The supplement covers system installation, field wiring, scale-factor verification, troubleshooting, probe construction and system performance. Use the exact product configuration and applicable revision when making replacement or maintenance decisions.

Related Models

The following are additional part numbers from the supplied catalogue pool. They are included for catalogue navigation only and are not presented as compatible replacements for this proximity probe.

Show related models
AMIKON Industrial Supply · Industrial automation and machinery-monitoring parts sourcing.

Send your inquiry directly to us