Product Description
AMIKON INDUSTRIAL SUPPLY / CONTROLLOGIX

1756-PB72 DC Power Supply ⚡

01 / PRODUCT OVERVIEW

Powering the ControlLogix Chassis

The 1756-PB72 converts its supplied DC input into the backplane power rails used by compatible ControlLogix chassis modules.

Before sourcing a replacement, confirm the installed catalog number, chassis type, input supply and required backplane capacity.

DC POWER CHASSIS MOUNTED BACKPLANE SUPPLY
IDENTIFICATION / 02
1756-PB72

MANUFACTURER
Allen-Bradley
PRODUCT FAMILY
ControlLogix
PRODUCT TYPE / LIFECYCLE
DC chassis power supply · Active
03 / ELECTRICAL PROFILE

Technical Specifications

POWER DATA ⚡
NOMINAL INPUT
24V DC
Operating range: 19–32V DC
MAX. OUTPUT
75W
Maximum rated output power
INPUT POWER
95W
Rated input power

Backplane Output Rails

5.1V DC
10.0A
3.3V DC
4.0A
1.2V DC
1.5A
24V DC
2.8A

Additional Ratings

Maximum inrush current 30A
Redundant configuration Not supported
Connection cables None required
UPC 612598172603
Verify the catalog number and nameplate before ordering. Individual output current ratings do not replace the 75W maximum total output rating.
04 / FIELD SETUP

Mounting, Wiring & Safety

Key installation points for planning and routine checks.

⚡
01

Mounting Position

Install the supply at the left end of a compatible ControlLogix chassis. Its connector mates directly with the backplane; make sure the unit is correctly seated and the chassis assembly is secure.

02

DC Wiring

Use a 24V DC source within the 19–32V DC operating range. Isolate power first, identify positive and negative conductors, connect to the corresponding input terminals and verify polarity before energizing.

03

Cable & Terminals

Use solid or stranded copper conductors rated for at least 90°C, sized at 14 AWG (2.5 mm²), within the specified insulation limits. Terminal torque is 0.565 N·m (5 lb-in); avoid overtightening.

04

Final Checks

Confirm chassis and module compatibility, input polarity, terminal connections and supply voltage before restoring power. Follow site electrical safety procedures and keep the equipment within its rated environment.

OPERATING TEMPERATURE
0°C to +60°C
Standard operating ambient range
POWER ISOLATION
Disconnect before servicing
Never wire or remove the supply while energized.
05 / FIELD SCENARIOS

Application & Failure Scenarios

When is this part searched for?

Typical sourcing situations include chassis power loss, a rack that will not power up, suspected power-supply failure, or planned maintenance requiring an exact catalog-number replacement.

What can downtime affect?

An interrupted chassis supply may affect controller and I/O operation, potentially stopping dependent machinery or production processes.

Before replacing the unit

Check the incoming DC source, wiring, chassis connections and installed modules. A rack fault does not automatically mean the power supply has failed.

!
CHECK BEFORE ORDERING

Replacement & Compatibility

Match the exact 1756-PB72 catalog number and verify the chassis, input voltage, module load and installed configuration. This model is not specified for a redundant power-supply configuration. Similar-looking part numbers are not automatically interchangeable.

TECHNICAL REFERENCE

1756-PB72 Manual, PDF & Datasheet

Relevant technical publications include 1756-IN619 for ControlLogix power supply installation and 1756-TD005 for power supply technical data. Use the mounting, wiring and safety checks above for routine planning, and apply the electrical and site requirements appropriate to the installed hardware.

06 / NEXT STEP

Request a Quotation

LET'S GET IT MOVING →

Send your part and delivery details to AMIKON for availability, pricing and order options.

01
Part Number
02
Quantity
03
Destination
04
Required Date
05
Machine/System Model
AMIKON INDUSTRIAL SUPPLY

Industrial Parts.
Practical Support.

Send us your part number and delivery requirements to start a quotation request.

CONTACT PERSON / MIYA ZHENG
EMAIL / QUOTATIONS
sales@amikon.cn
WHATSAPP / DIRECT CONTACT
+86 180 2077 6792
Testing scope, item condition, packaging, dispatch schedule and warranty terms are confirmed with the quotation.
AMIKON industrial parts sourcing and service team
INDUSTRIAL SUPPORT
+
PARTS SOURCING / MAINTENANCE
Support for Your Next Maintenance Requirement
ORDER INFORMATION

Delivery & Warranty

Testing

Inspection or testing scope is confirmed with the quotation. Item condition and procedures are not assumed unless specified in writing.

Packaging & Delivery

Packaging, dispatch schedule and estimated delivery are confirmed for each order.

Returns & DOA

Report damaged, incorrect or non-operational items promptly with order details and supporting evidence. Return authorization and remedies follow the agreed terms.

Warranty

12 months, subject to quotation terms. Coverage, exclusions and remedies for verified defects are governed by the order agreement.

QUICK ANSWERS

Frequently Asked Questions

1. What input voltage does the 1756-PB72 require?

The nominal input is 24V DC, with a published operating range of 19–32V DC. Verify the incoming supply and polarity before commissioning.

2. What output rails are provided?

The listed outputs are 5.1V DC at 10.0A, 3.3V DC at 4.0A, 1.2V DC at 1.5A and 24V DC at 2.8A. Maximum total output power is 75W.

3. Does the 1756-PB72 support redundant power supplies?

No. This model is not specified for a redundant power-supply configuration. Confirm the required system architecture before choosing an alternative.

4. What details should I provide for a replacement quotation?

Provide the part number, quantity, destination, required date and machine/system model. Nameplate information and a description of the fault can also help identify the correct item.

Related Models & Industrial Parts Reference

Reference models for broader industrial parts sourcing. These items are not confirmed compatible replacements for the 1756-PB72. Confirm each model and application independently.

Siemens 6SL3352-1AE41-2FA1 SEW RF87 DRS90L4 IC695PNC001 HACH DR2800 Siemens 1FT7108-5AB71-1BG0 ABB ACS580-01-106A-4 IC693CPU350-EK SEW K67 DRN100L4/BE5HR/MM30/AMA6 6SL3210-1PE33-0CL0 Converteam LV7000 5-01685A0T0ISFA1A2000000 1756-OF6VI HACH DR4900 Siemens 6SL3000-0CE41-5AA0 Siemens 1FK7103-5AF71-1EH0 IC200ALG321 HACH LICO500 SEW KT67/T DRP100L4/MM22/AMA6/EI71 Siemens 6ES7155-7AA21-0AB0 IC695PSA040 FC-302P22KT5E21H1XGXXXXSXXXXAXBXCXXXXDX Siemens 1FT7105-1AC71-1CH1 SEW MDS60A0370-503-4-0T IC693CMM321 HACH PHC281 6SL3352-1AE33-8AA1 Siemens 1FT5102-0AF71-2-Z IC695CMM004-E Grundfos MTR10-14/2 X-W-I-HUUV SATI SPC1000-04 5050 19-0379 Siemens 6SL3352-1AE37-5CA1 IC695ALG704 HACH PHC805 SEW RF77 DRN100LS4/BE5/TH 6SL3310-1CE35-2AA0 IC695PNC001LT HACH SIP10 Siemens 1FK7105-3BC71-1QA0 Siemens 6SL3130-7TE25-5AA3 HACH DR5000 PS-2-BS 2731429 Siemens 6GK5202-2BB00-2BA3 IC693CMM321-MK HACH LDO101 Siemens 1FG1502-5RE23-2AN1-Z 6SL3300-7TE33-8AA0 IC695CMM004-BF MDD115B-N-020-N2L-130GA0 32100AZD-90L/4 BRE20 6SL3353-1AE38-2DA1 INET300 HACH LQV157 Siemens 1FT6084-8AK71-4AH1 6SL3353-1AE35-5AA0 R3G500-PB24-XM MGE132SE 2-FF265-JA-550 SP3403 6SL3353-1AE41-3FA0 119-2013-001 HQL100S Wilo IL50/120-2.2/2 2088343 SEW FH67/G CMP80S/KY/AK0H/SM1 15AA80M ES160.100.85.64 KT08.0047 ATW8.100 19S23-RS0P1-N28R-ST5S00N-R0SU Demag KBA 71 A2 + KBL 71 A8 + AF05 + FG06 KA57/T CMPZ71M/BY/PK/AK1H/KK F-RZ/400/XF/WK/WTX/S52/SA/3/4/S/00/K CM112L/BR/TF/AS1H/SB60 G50BH132MVBR2C00 E84DGDVB55242PS Lenze GKS05-3N VBR 2D 08F12 302A ISA-LXMX-A-400-20-1200-T2-X10-AQ-B-EU-W-SP
AMIKON Industrial Supply

Send your inquiry directly to us