| Feature | Specification |
|---|---|
| Module Type | 3500/61 RTD/TC I/O Module |
| Part Number | 136711-02 |
| Module Configuration | Internal Barriers with Internal Terminations |
| Compatibility | Pairs with 3500/61 Temperature Monitor Module |
| Channel Support | 6-channel RTD/Thermocouple interface |
| Safety Protection | Internal intrinsic safety barriers |
| Hazardous Area Protection | Designed for use with intrinsically safe field wiring applications |
| Power Consumption | 9 W nominal |
| Accuracy | Function of sensor type and monitor configuration |
| Operating Temperature | 0°C to +65°C (32°F to +150°F) |
| Rack Installation | Mounts in the rear of the 3500 rack, directly behind the monitor |
| Project Scenario | How We Helped | Result |
|---|---|---|
| Robotic packaging system upgrade | Delivered components on time and recommended wiring optimizations | Improved installation efficiency and reduced setup time |
| Production expansion facing supply chain delays | Quickly sourced alternative components to maintain schedules | Helped the customer meet critical project deadlines |
| Chemical plant expansion project | Assisted with selecting compatible PLCs, drives, and sensors | Achieved smooth system integration and stable operation |
| Bottling line automation startup | Supplied complete controller solutions and calibration support | Accelerated commissioning and reduced startup delays |
| Emergency maintenance shutdown | Arranged overnight shipment and remote installation assistance | Minimized downtime and avoided production losses |
Contact our team today for pricing, availability, and fast global delivery.
Contact: Miya Zheng
Email: sales@amikon.cn
WhatsApp: +86 180 2077 6792
![]()
Q: What is the primary function of the Bently Nevada 136711-02 in a 3500 system?
A: You can basically treat the 136711-02 like the “back connection point” for temperature wiring inside a Bently Nevada 3500 rack. It sits at the rear side, working together with a 3500/61 monitor module. RTD or thermocouple signals come in through this 6-channel RTD/TC I/O module, then get passed forward into the system. Without the 136711-02, the whole temperature input path to the monitor just doesn’t really happen.
Q: How does the 136711-02 differ from the standard 136711-01 I/O module?
A: The main split is pretty straightforward: the 136711-02 has internal barriers, the 136711-01 doesn’t. That one detail decides a lot in real projects. If the site is hazardous area or needs intrinsic safety, engineers usually go straight for the 136711-02. It limits energy going out to field devices, so it’s more suitable for Oil & Gas or any “no spark allowed” zone. The 136711-01 is more for general use where those rules aren’t strict.
Q: Can the 136711-02 support both RTDs and Thermocouples simultaneously?
A: Yes, and that’s quite common in real applications. The 136711-02 doesn’t force you to choose one sensor type. You can mix RTDs and thermocouples on the same 6 channels depending on the machine setup. For example, a turbine might use different temperature points with different sensor types, and this module handles that without much issue.
Q: What are the installation requirements for the 136711-02 within the rack?
A: Installation is more about correct placement than complexity. The 136711-02 has to be inserted into the rear full-height slot and aligned directly behind the 3500/61 monitor. This alignment matters—if it’s off by even one slot, the connector won’t match and communication problems can show up. In practice, technicians usually just double-check seating before powering the rack.
Q: Does the 136711-02 provide protection for Class I, Division 1 hazardous areas?
A: Yes. That’s mainly because of the internal intrinsic safety barriers built into the 136711-02 I/O module. It reduces the energy going to field wiring, which is what makes it suitable for Class I Div 1 or Zone 0 areas. Also, it helps reduce the need for external barrier modules in the cabinet, so the setup is a bit more compact.
Q: What is the power consumption of the 136711-02 I/O module?
A: Around 9W nominal. Not high, but in a full Bently Nevada 3500 system it still needs to be counted. When you’re planning multiple 3500/61 temperature I/O modules in one rack, each 136711-02 adds to the total power budget, so the power supply sizing usually takes this into account.
| 3500/15E | 125720-02 |
| 136711-01 | 138708-01 |
| 330703-000-040-10-11-00 | 330104-00-08-10-02-00 |
| 330705-02-18-10-02-00 | 330105-02-12-05-02-CN |
| 330703-000-070-10-02-00 | 330130-045-00-CN |
| 330101-10-27-05-02-05 | 330103-00-04-05-02-00 |
| 330878-50-00 | 330850-90-05 |
| 330103-00-12-10-01-00 | 3500/32 125712-01 |
| 330103-00-16-10-01-00 | 991-01-XX-02-05 |
| RS901104-03-050-10-01 R200602-400808 | 9200-06-05-05-00 |
| 330105-02-12-50-02-00 | 330101-00-28-05-02-00 |
| 350500-00-00-00-11-00 | 330103-00-06-05-02-00 |
| 330190-080-01-00 | 330106-05-30-15-02-00 |
| 3500/77M 140734-07 | 330101-00-63-10-02-00 |
| 2201/03-01 | 330103-00-08-05-02-00 |
| 1900/65 | 330103-00-07-10-02-00 |
| 21747-080-00 | 330103-07-18-10-02-00 |
| 330730-080-01-00 | 330130-075-00-00 |
| 330930-060-00-00 | 330104-00-16-10-02-00 |
| 125388-01H 125388-01 | 330703-000-040-10-02-00 |