logo
Σπίτι > προϊόντα > BENTLY NEVADA >
Bently Nevada 136711-02 3500/61 I/O Module

Bently Nevada 136711-02 3500/61 I/O Module

136711-02 I/O Module 6-channel RTD/TC interface

Internal Barriers Bently Nevada 3500 rack

Gas turbine exhaust monitoring Steam turbine bearing temperature

Τόπος καταγωγής:

ΗΠΑ

Μάρκα:

Bently Nevada

Αριθμό μοντέλου:

136711-02

Μας ελάτε σε επαφή με
Ζητήστε ένα απόσπασμα
Λεπτομέρειες προιόντος
Country of origin:
USA
Shipping:
TNT, DHL, FedEx, EMS, UPS
MOQ:
1 piece
Packaging:
Original new packaging
Estimated Shipping Size:
2.5x18.5x24.2cm
Weight:
0.98 kg
Model:
136711-02
Country of origin:
USA
Place of shipment:
Xiamen,China
Shipping:
TNT, DHL, FedEx, EMS, UPS
MOQ:
1 piece
Packaging:
Original new packaging
Estimated Shipping Size:
2.5x18.5x24.2cm
Weight:
0.98 kg
Model:
136711-02
Shipping:
TNT, DHL, FedEx, EMS, UPS
MOQ:
1 piece
Estimated Shipping Size:
2.5x18.5x24.2cm
Model:
136711-02
Place of shipment:
Xiamen,China
Shipping:
TNT, DHL, FedEx, EMS, UPS
Estimated Shipping Size:
2.5x18.5x24.2cm
Weight:
0.98 kg
Μοντέλο:
136711-02
Χώρα προέλευσης:
ΗΠΑ
Τόπος αποστολής:
Xiamen, Κίνα
ΑΠΟΣΤΟΛΗ:
TNT, DHL, FedEx, EMS, UPS
MOQ:
1 τεμάχιο
Συσκευασία:
Πρωτότυπη νέα συσκευασία
Εκτιμώμενο μέγεθος αποστολής:
2,5x18,5x24,2 εκ
βάρος:
0,98 κιλά
Μοντέλο:
136711-02
Χώρα προέλευσης:
ΗΠΑ
Τόπος αποστολής:
Xiamen, Κίνα
ΑΠΟΣΤΟΛΗ:
TNT, DHL, FedEx, EMS, UPS
MOQ:
1 τεμάχιο
Συσκευασία:
Πρωτότυπη νέα συσκευασία
Εκτιμώμενο μέγεθος αποστολής:
2,5x18,5x24,2 εκ
βάρος:
0,98 κιλά
Επισημαίνω:

136711-02 I/O Module 6-channel RTD/TC interface

,

Internal Barriers Bently Nevada 3500 rack

,

Gas turbine exhaust monitoring Steam turbine bearing temperature

Όροι πληρωμής & ναυτιλίας
Ποσότητα παραγγελίας min
1
Τιμή
66USD
Συσκευασία λεπτομέρειες
Ολοκαίνουργιο και πρωτότυπο
Χρόνος παράδοσης
2-3 εργάσιμες
Όροι πληρωμής
T/T
Δυνατότητα προσφοράς
σε απόθεμα
Συγγενικά προϊόντα
Μας ελάτε σε επαφή με
Επαφή τώρα
Περιγραφή προϊόντων
Bently Nevada 136711-02 3500/61 I/O Module
Bently Nevada 136711-02 3500/61 I/O Module 0
Feature Specification
Module Type 3500/61 RTD/TC I/O Module
Part Number 136711-02
Module Configuration Internal Barriers with Internal Terminations
Compatibility Pairs with 3500/61 Temperature Monitor Module
Channel Support 6-channel RTD/Thermocouple interface
Safety Protection Internal intrinsic safety barriers
Hazardous Area Protection Designed for use with intrinsically safe field wiring applications
Power Consumption 9 W nominal
Accuracy Function of sensor type and monitor configuration
Operating Temperature 0°C to +65°C (32°F to +150°F)
Rack Installation Mounts in the rear of the 3500 rack, directly behind the monitor
Bently Nevada 136711-02 3500/61 I/O Module 1
Project Scenario How We Helped Result
Robotic packaging system upgrade Delivered components on time and recommended wiring optimizations Improved installation efficiency and reduced setup time
Production expansion facing supply chain delays Quickly sourced alternative components to maintain schedules Helped the customer meet critical project deadlines
Chemical plant expansion project Assisted with selecting compatible PLCs, drives, and sensors Achieved smooth system integration and stable operation
Bottling line automation startup Supplied complete controller solutions and calibration support Accelerated commissioning and reduced startup delays
Emergency maintenance shutdown Arranged overnight shipment and remote installation assistance Minimized downtime and avoided production losses
Need reliable automation parts and responsive technical support?

Contact our team today for pricing, availability, and fast global delivery.

Contact: Miya Zheng

Email: sales@amikon.cn

WhatsApp: +86 180 2077 6792

Bently Nevada 136711-02 3500/61 I/O Module 2 Bently Nevada 136711-02 3500/61 I/O Module 3
  • Hazardous Area Machinery Protection - Hazardous area machinery protection is really the main use case here. In IS (intrinsic safety) environments, the 136711-02 comes in because of the internal barriers. It lets RTD and thermocouple signals go through safely in Class I, Division 1 or Zone 0 setups, basically where you don’t want any risk on the field wiring side.
  • Steam and Gas Turbine Monitoring - For steam and gas turbines, this module shows up quite a lot in power plants. You’re usually looking at bearing temperatures, exhaust gas points, those high-heat areas that need stable monitoring. The 136711-02 sits in the 3500 rack and just keeps those temperature signals flowing into the 3500/61 monitor without much fuss.
  • Centrifugal and Axial Compressor Protection - On centrifugal and axial compressors, especially in Oil & Gas, it’s used for stator winding temps and discharge gas temperatures. Nothing fancy in operation, but it’s important because these machines run hard and you need continuous temperature visibility.
  • API 670 Compliant Systems - In API 670 compliant systems, it fits into the broader machinery protection setup. Alarm logic, shutdown signals, protection layers—this module is just part of that chain, handling the temperature input side for the 3500 system.
  • Industrial Rotating Machinery - For industrial rotating machinery like large motors or generators, it’s often used to catch early signs like insulation issues or cooling problems. Usually multiple RTDs or thermocouples are spread across the machine and routed back through this 6-channel RTD/TC I/O module.
  • Critical Asset Temperature Profiling

    And when it comes to critical asset temperature profiling, this is where it becomes more of a data backbone. You get dense temperature inputs from different points, which helps condition monitoring and predictive maintenance systems spot changes before they turn into failures.

Bently Nevada 136711-02 3500/61 I/O Module 4
  • Integrated Intrinsic Safety Barriers - Intrinsic safety is kind of the first thing people care about with the 136711-02. The internal barriers are already built in, so field wiring in hazardous areas can be connected directly without adding external barrier strips in the cabinet. It just simplifies things on site, especially in IS environments.
  • Universal 6-Channel Temperature Interface - On the signal side, it’s a 6-channel temperature interface. You’ve got up to six inputs, and it doesn’t really lock you into one sensor type—RTDs and thermocouples both work on the same module. That flexibility is usually why it gets picked in mixed temperature monitoring setups.
  • Internal Termination Design - The internal termination design is another practical detail. Wiring comes straight into the module and gets terminated internally, so you don’t end up with a messy external termination setup. Signal integrity is generally more stable that way, especially in longer runs.
  • Dedicated 3500/61 Monitor Pairing - It’s also clearly meant to work with the Bently Nevada 3500/61 temperature monitor. The pairing is pretty direct—136711-02 sits in the rack and feeds temperature data straight into that monitor module inside the 3500 system. In real installations, they’re basically treated as a matched set.
  • API 670 Compliant Protection - From a standards point of view, it’s aligned with API 670 requirements for machinery protection systems. That means it fits into setups where alarms, trips, and protection logic are built around that standard, mostly in turbines and critical rotating equipment.
  • Rugged Industrial Reliability - And on the physical side, it’s built for industrial environments rather than clean lab conditions. Continuous operation, vibration, heat… it’s designed for that kind of reality. Operating range is roughly 0°C to +65°C, which is pretty standard for plant-floor instrumentation.


Bently Nevada 136711-02 3500/61 I/O Module 5


Q: What is the primary function of the Bently Nevada 136711-02 in a 3500 system?
A: You can basically treat the 136711-02 like the “back connection point” for temperature wiring inside a Bently Nevada 3500 rack. It sits at the rear side, working together with a 3500/61 monitor module. RTD or thermocouple signals come in through this 6-channel RTD/TC I/O module, then get passed forward into the system. Without the 136711-02, the whole temperature input path to the monitor just doesn’t really happen.


Q: How does the 136711-02 differ from the standard 136711-01 I/O module?
A: The main split is pretty straightforward: the 136711-02 has internal barriers, the 136711-01 doesn’t. That one detail decides a lot in real projects. If the site is hazardous area or needs intrinsic safety, engineers usually go straight for the 136711-02. It limits energy going out to field devices, so it’s more suitable for Oil & Gas or any “no spark allowed” zone. The 136711-01 is more for general use where those rules aren’t strict.


Q: Can the 136711-02 support both RTDs and Thermocouples simultaneously?
A: Yes, and that’s quite common in real applications. The 136711-02 doesn’t force you to choose one sensor type. You can mix RTDs and thermocouples on the same 6 channels depending on the machine setup. For example, a turbine might use different temperature points with different sensor types, and this module handles that without much issue.


Q: What are the installation requirements for the 136711-02 within the rack?
A: Installation is more about correct placement than complexity. The 136711-02 has to be inserted into the rear full-height slot and aligned directly behind the 3500/61 monitor. This alignment matters—if it’s off by even one slot, the connector won’t match and communication problems can show up. In practice, technicians usually just double-check seating before powering the rack.


Q: Does the 136711-02 provide protection for Class I, Division 1 hazardous areas?
A: Yes. That’s mainly because of the internal intrinsic safety barriers built into the 136711-02 I/O module. It reduces the energy going to field wiring, which is what makes it suitable for Class I Div 1 or Zone 0 areas. Also, it helps reduce the need for external barrier modules in the cabinet, so the setup is a bit more compact.


Q: What is the power consumption of the 136711-02 I/O module?
A: Around 9W nominal. Not high, but in a full Bently Nevada 3500 system it still needs to be counted. When you’re planning multiple 3500/61 temperature I/O modules in one rack, each 136711-02 adds to the total power budget, so the power supply sizing usually takes this into account.

Bently Nevada 136711-02 3500/61 I/O Module 6
3500/15E 125720-02
136711-01 138708-01
330703-000-040-10-11-00 330104-00-08-10-02-00
330705-02-18-10-02-00 330105-02-12-05-02-CN
330703-000-070-10-02-00 330130-045-00-CN
330101-10-27-05-02-05 330103-00-04-05-02-00
330878-50-00 330850-90-05
330103-00-12-10-01-00 3500/32 125712-01
330103-00-16-10-01-00 991-01-XX-02-05
RS901104-03-050-10-01 R200602-400808 9200-06-05-05-00
330105-02-12-50-02-00 330101-00-28-05-02-00
350500-00-00-00-11-00 330103-00-06-05-02-00
330190-080-01-00 330106-05-30-15-02-00
3500/77M 140734-07 330101-00-63-10-02-00
2201/03-01 330103-00-08-05-02-00
1900/65 330103-00-07-10-02-00
21747-080-00 330103-07-18-10-02-00
330730-080-01-00 330130-075-00-00
330930-060-00-00 330104-00-16-10-02-00
125388-01H 125388-01 330703-000-040-10-02-00

Μας στείλετε την έρευνά σας άμεσα σε