8M Sensitive-Ground CT/VT Module

4 CT Inputs and 4 VT Inputs

UR8MH datasheet

Place of Origin:

USA

Brand Name:

General Electric

Contact Us
Request A Quote
Product Details
Highlight:

8M Sensitive-Ground CT/VT Module

,

4 CT Inputs and 4 VT Inputs

,

UR8MH datasheet

Payment & Shipping Terms
Minimum Order Quantity
1
Packaging Details
Brand new and original
Delivery Time
2-3 work days
Payment Terms
T/T
Supply Ability
in Stock
Product Description
AMIKON Industrial Supply / GE Multilin

GE Multilin UR8MH CT/VT

Sensitive-ground CT/VT input option for compatible GE Multilin Universal Relay systems, combining current and voltage measurement channels with enhanced hardware diagnostics.

UR8M
Industrial Parts Sourcing

Send the part number and host relay details to request availability, testing scope and a quotation.

REQUEST A QUOTATION  →
01 / FUNCTION

Product Overview

Measurement interface and sensitive-ground function.

Current & Voltage Signal Acquisition

UR8MH serves as the analog measurement interface within a compatible GE Multilin Universal Relay. It receives instrument-transformer signals from the electrical system and supplies measurement data for the host relay's protection, metering and supervision functions.

Sensitive-Ground Measurement

The 8M option provides a sensitive-ground current input arrangement. Enhanced diagnostics monitor CT/VT measurement hardware and identify internal analog-channel integrity problems.

02 / DATA

Technical Specifications

Core configuration, electrical ratings and installation references.

Module Type & Input Configuration
Manufacturer: GE Multilin / GE Grid Solutions Model: UR8MH Product family: Universal Relay (UR) Module option: 8M – Sensitive-Ground CT/VT with Enhanced Diagnostics Current inputs: 4 CT inputs Voltage inputs: 4 VT inputs Input grouping: Channels 1–4 current input bank; channels 5–8 voltage input bank Phase assignment: 1–3 phase A/B/C current; 4 ground current IG Voltage assignment: 5–7 phase A/B/C voltage; 8 auxiliary voltage VX Ground input: Sensitive-ground current input Diagnostics: CT/VT analog-channel integrity monitoring and internal hardware failure detection
Current Transformer (CT) Input Data
CT primary rating: 1 to 50,000 A CT secondary rating: 1 A or 5 A, selected by connection Standard CT conversion range: 0.02 to 46 × CT rating RMS symmetrical Sensitive-ground CT range: 0.002 to 4.6 × CT rating RMS symmetrical Input isolation: Isolating transformer on each AC current input Input grounding: No internal ground connections on current inputs Withdrawal protection: Automatic shorting mechanism shorts the current input when the module is withdrawn from the chassis

The sensitive-ground CT input is 10 times more sensitive than the standard ground-current input. Phase CT inputs retain the characteristics of regular CT/VT modules.

Voltage Transformer (VT) Input Data
VT rated secondary: 25.0 to 240.0 V VT ratio: 1.00 to 24,000.00 Voltage conversion range: 1 to 275 V Relay burden: Less than 0.25 VA at 120 V Voltage withstand: Continuous at 260 V to neutral; 1 minute per hour at 420 V to neutral
Wiring & Installation Reference
Common conductor size: 12 AWG Maximum conductor size: 10 AWG CT terminal groups: IA, IB, IC and IG VT terminal groups: VA, VB, VC and VX Zero-sequence CT cable: Twisted-pair cabling recommended

Actual terminal and slot positions depend on the relay configuration. Follow the wiring diagram for the installed relay and module arrangement. CT secondary circuits must be handled under the approved isolation and shorting procedure.

03 / SUPERVISION

Enhanced Diagnostics

Analog data integrity and internal hardware supervision.

The 8M module uses analog data-integrity validation to compare the hardware analog summation with digitally sampled channel data. It also monitors module power-supply voltage rails and internal CT secondary circuitry.

Diagnostic response: When invalid analog data is detected, affected protection functions are momentarily blocked. If the error persists, the relay can display a major self-test diagnostic message, operate its self-test alarm contact and be taken out of service.

Enhanced CT/VT diagnostics are supported by UR firmware version 5.20 and later. Older installations may require a compatible relay hardware or firmware upgrade before the feature can be used.

04 / FIELD USE

Application & Failure Scenarios

Typical system use, sourcing triggers and downtime considerations.

Typical System Application

Installed in compatible GE Multilin Universal Relay protection systems that require current and voltage measurement from external CTs and VTs. The host relay may be applied to generator, transformer, feeder or motor protection, depending on the relay model and configured protection functions.

Why It Is Sourced

Customers may search for this module after CT/VT measurement errors, internal analog-channel diagnostic alarms, abnormal current or voltage readings, or a module hardware fault. Loss of reliable measurement can block associated protection functions or take the relay out of service, increasing protection-system downtime risk.

Replacement verification: Confirm the complete relay model and order code, CPU/DSP hardware generation, module option, slot arrangement, CT secondary rating, VT wiring and firmware version. Do not assume another UR CT/VT option is interchangeable.
05 / SUPPLY

Delivery & Warranty

Inspection, packing and order handling.

Inspection & Testing Inspection and functional test scope confirmed with the quotation.
Protective Packaging Protective packing for electronic modules and international transportation.
DOA & Returns Report DOA issues promptly with order details and supporting evidence. Return approval follows agreed terms.
12-Month Warranty Warranty subject to quotation terms; coverage and exclusions confirmed before order.
RFQ requirements: Part Number, Quantity, Destination, Required Date and Machine/System Model.
06 / FAQ

Frequently Asked Questions

Common technical and sourcing questions.

01

What is the difference between the UR8MH and a standard CT/VT module?

The UR8MH uses the sensitive-ground 8M arrangement and includes enhanced CT/VT diagnostics. Its sensitive-ground current input provides greater sensitivity than a standard ground-current input.

02

Which UR firmware is required for enhanced diagnostics?

GE documentation identifies firmware version 5.20 or later as supporting enhanced CT/VT diagnostics. Confirm the installed relay hardware and firmware before planning an upgrade or replacement.

03

Can the current inputs accept both 1 A and 5 A CT secondaries?

The UR CT input arrangement supports either secondary rating through the corresponding terminals. The connected CT rating and relay configuration must match the selected connection.

04

What happens when an internal CT/VT diagnostic failure is detected?

The relay can identify invalid analog data, temporarily block affected protection functions and, if the error persists, generate a major self-test alarm and take the relay out of service.

05

Can the UR8MH be installed in every GE Multilin Universal Relay?

No universal compatibility should be assumed. Confirm the host relay model, hardware generation, module support, slot configuration and firmware requirements before ordering.

AMIKON Industrial Supply

Industrial Parts Sourcing, Backed by 20+ Years of Experience.

Practical sourcing support for industrial automation and maintenance requirements.

AMIKON industrial parts sourcing service
AMIKON industrial supply and customer support
20+ YEARS · INDUSTRIAL SUPPLY EXPERIENCE

Miya Zheng | Sales Contact

Email sales@amikon.cn WhatsApp +86 180 2077 6792
AMIKON is an independent industrial parts supplier and is not affiliated with or authorized by GE Vernova unless expressly stated in the quotation.
07 / SOURCING RANGE

Related Models

Additional industrial parts references.

View Related Models List
08 / REFERENCE

Documentation

Manufacturer reference material.

GE official references: UR Family CT/VT Modules with Enhanced Diagnostics, Technical Note GET-20065; GE Multilin UR Family Instruction Manual, CT/VT module specifications and installation guidance. For the UR8MH datasheet and manual PDF, match the host relay model, module option and firmware revision against the applicable GE documentation before installation.

Send your inquiry directly to us