Sensitive-ground CT/VT input option for compatible GE Multilin Universal Relay systems, combining current and voltage measurement channels with enhanced hardware diagnostics.
Send the part number and host relay details to request availability, testing scope and a quotation.
REQUEST A QUOTATION →Measurement interface and sensitive-ground function.
UR8MH serves as the analog measurement interface within a compatible GE Multilin Universal Relay. It receives instrument-transformer signals from the electrical system and supplies measurement data for the host relay's protection, metering and supervision functions.
The 8M option provides a sensitive-ground current input arrangement. Enhanced diagnostics monitor CT/VT measurement hardware and identify internal analog-channel integrity problems.
Core configuration, electrical ratings and installation references.
The sensitive-ground CT input is 10 times more sensitive than the standard ground-current input. Phase CT inputs retain the characteristics of regular CT/VT modules.
Actual terminal and slot positions depend on the relay configuration. Follow the wiring diagram for the installed relay and module arrangement. CT secondary circuits must be handled under the approved isolation and shorting procedure.
Analog data integrity and internal hardware supervision.
The 8M module uses analog data-integrity validation to compare the hardware analog summation with digitally sampled channel data. It also monitors module power-supply voltage rails and internal CT secondary circuitry.
Enhanced CT/VT diagnostics are supported by UR firmware version 5.20 and later. Older installations may require a compatible relay hardware or firmware upgrade before the feature can be used.
Typical system use, sourcing triggers and downtime considerations.
Installed in compatible GE Multilin Universal Relay protection systems that require current and voltage measurement from external CTs and VTs. The host relay may be applied to generator, transformer, feeder or motor protection, depending on the relay model and configured protection functions.
Customers may search for this module after CT/VT measurement errors, internal analog-channel diagnostic alarms, abnormal current or voltage readings, or a module hardware fault. Loss of reliable measurement can block associated protection functions or take the relay out of service, increasing protection-system downtime risk.
Inspection, packing and order handling.
Common technical and sourcing questions.
The UR8MH uses the sensitive-ground 8M arrangement and includes enhanced CT/VT diagnostics. Its sensitive-ground current input provides greater sensitivity than a standard ground-current input.
GE documentation identifies firmware version 5.20 or later as supporting enhanced CT/VT diagnostics. Confirm the installed relay hardware and firmware before planning an upgrade or replacement.
The UR CT input arrangement supports either secondary rating through the corresponding terminals. The connected CT rating and relay configuration must match the selected connection.
The relay can identify invalid analog data, temporarily block affected protection functions and, if the error persists, generate a major self-test alarm and take the relay out of service.
No universal compatibility should be assumed. Confirm the host relay model, hardware generation, module support, slot configuration and firmware requirements before ordering.
Practical sourcing support for industrial automation and maintenance requirements.
Miya Zheng | Sales Contact
Email sales@amikon.cn WhatsApp +86 180 2077 6792Additional industrial parts references.
| HACH PHC281 | Siemens 6AV8021-1JE22-0CA0 | MGFAS4-DSM-DSC-B/ECR/ET | X20IF1091 | SEW SF47 DRN71M2/BE05/Z |
| ECM01 | R57 DRN71M4/TH | Siemens 4EU2752-1UB00-0AA0 | FBLD120CW | KT37 DRS71M4BE1/TF |
| Siemens 1FT7062-5AK71-1CB5-Z Z=N05 | HACH DR4900 | KH37 DRN80M4/BE1HR/IS/TF | 801PLUS-16-BLK-RL | X20DO4633 |
| Rittal AX 1073.000 | DRN71M4/BE05/TH | Siemens 6AV7613-0AB13-0CE0 | MG100LB4-28FF215-H3 | SN062D |
| 1450001875 + VEM K21R 63 G 4 TPM140 | Siemens 7UT5131-5CA00-0C/HH | X20BC0073 | DT80N4 | HACH LQV157 |
| AEG Microverter D 20/380 029.136161 | MFDC560 ZMA072E | Siemens 1LE10011BA240AA4 | Siemens 4AT3095-0UA01-0J | R37 DRN71M2/BE05/Z |
| SMT1500IC | X20SC2212 | SEW R57 DRS71M4BE1HF/TF | HACH PHC805 | Siemens 6AV7714-1DC42-0AD0 |
| GKK05-2M VAR 063C32 MFEMABR063-32C13 | RF37 DRE80M4BE05 | U6X-K 97005046 | Siemens 7UT5135-5CA00-0C/GG | 8I76T401500.0P-000 |
| HA103NC-S | SEW KT37 DRN80M4/TF | 1FK7081-5AZ91-1ZZ9-Z SRM50-HXV0-K02 | BW601/9500/9 | X20BM26 |
| Siemens 1AV3094A 1LE10030EA490NB4-Z | 6237.400.V3 | 4KTCD 80 A-4 EX | Siemens 6AV7613-0AB11-0CE0 | SEW SF57 DRS71M6 |
| ATEK V160 | Siemens 4EU2752-0UB00-0AA0 | 05F033W48961 | VCM322/M21R100L4T 192H1322 | R37 DRN80MK4/BE1/TH |
| X20BC0043-10 | Grimm VNB 15 | DSBC-L1-125-650-D3-PPSA-N3 | RF27 DRE90M4/TH | Siemens 1FT6084-1AF71-1EG1 |
| MGFAT4-DSM-DSC-B/ECR/IV/DSP/PG | Siemens 6AV7613-0AB13-0CE0 | X20IF10G3-1 | CNFMS012-6120DAEB-731/GV63S/4 | Siemens 4AT3095-0UA01-0J |
| Sitema SK 045 022 | Siemens 1FT7062-5AK71-1CB5-Z Z=N05 | SEW KF29B DRP90M4/MM11/TH/EI71/LN IM3A | Siemens 7UT5135-5CA00-0C/GG | R57 DRN71M4/TH |
| Siemens 6AV8021-1JE22-0CA0 | 80M04 | SEW SF47 DRN71M2/BE05/Z | X20CP0483 | Mayr RSM 60/891.104.0 S 8284274 13579606 |
| FC-280P22KT4E20H1BXCXXXSXXAL 134U7741 | 180-MF2-40-020-000 | X20BM36 | STN2.5 STN2P5-I2-G2 | Siemens 7UT5131-5CA00-0C/HH |
| RF37 DY71ML/B/TH/AV1Y/SM203 | SAF47 DRS71M4 | HACH PHC281 | Siemens 1FT6084-1AF71-1EG1 | X20DC137A |
| MDEMABR063-12C0U | RQ11FB11CS0B3 13369484 | Siemens 6AV7613-0AB11-0CE0 | SEW KF29B DRP90M4/MM11/TH/EI71/LN IM3B | Siemens 4EU2752-0UB00-0AA0 |
Manufacturer reference material.
GE official references: UR Family CT/VT Modules with Enhanced Diagnostics, Technical Note GET-20065; GE Multilin UR Family Instruction Manual, CT/VT module specifications and installation guidance. For the UR8MH datasheet and manual PDF, match the host relay model, module option and firmware revision against the applicable GE documentation before installation.
Send your inquiry directly to us