Electric-driven proximity system test kit for checking static displacement response, dynamic vibration response and connected monitor behavior without running the machine.
↔Metric scale
⚡European cord
00No approvals
50–254 μm VIBRATION, P-P
0–5000 cpm VARIABLE SPEED
0–25.4 mm MICROMETER
5.22 kg NET WEIGHT
01 · VERIFY THE COMPLETE LOOP
Two checks, one portable bench
⌖
Static gap check
Move the target with the spindle micrometer, record voltage against distance, then assess usable range, scale factor and linearity of the installed probe chain.
◉
Dynamic response check
Run the motor-driven wobble plate at a controlled speed and amplitude to compare transducer voltage with the vibration value shown by the connected channel.
02 · OPERATING PARAMETERS
TK-3E 177313-02-02-00 bench profile
ITEM
VALUE
Drive
Electric, variable speed
Dynamic amplitude
50 to 254 μm peak-to-peak (2 to 10 mil)
Speed
0 to 5000 cpm, tolerance ±1000 cpm
Spindle travel
0 to 25.4 mm (0 to 1000 mil)
Input
95–125 Vac or 190–250 Vac, 50/60 Hz, 1 A minimum
Operating temperature
0 to 50°C
Humidity
Up to 95%, non-condensing
Enclosure
195 × 299 × 248 mm; 5.22 kg
Target material
AISI 4140 alloy steel
03 · WORKFLOW AND SYSTEM PLACE
From probe chain to monitor channel
① Mount Secure probe in holder
›
② Gap Move target precisely
›
③ Rotate Set wobble speed
›
④ Compare Voltage vs channel
Use the same probe, extension cable and Proximitor sensor combination that belongs to the machine loop. The bench creates mechanical input; it does not replace the electrical matching within that chain.
AMIKON · SINCE 2005
Industrial automation spares for planned maintenance and urgent recovery
PLC, HMI, DCS, industrial PC and drive components supported by an experienced sales team. Hard-to-find part numbers and complex spare requirements are handled with responsive global service.
EMAIL
WHATSAPP
04 · FAMILY CHOICE
Select the drive and scale for the work site
MODEL
DRIVE
SCALE
DISTINCTION
177313-01-01-00
Electric
English
American cord
177313-02-02-00
Electric
Metric
European cord
177314-02-00
Air
Metric
Suited where electric drive is undesirable
05 · FIELD FAQ
Decisions that affect a valid test
Ⓠ Can TK-3E 177313-02-02-00 validate both the transducer chain and monitor channel?
Yes. Static target movement checks the proximity chain, while the rotating wobble plate supplies a dynamic input that can be compared with the connected channel reading.
Ⓠ Why can TK-3E 177313-02-02-00 show a scale-factor shift even when every component works?
Target metallurgy affects eddy-current response. Compare against the AISI 4140 bench target, then account for the actual shaft material when setting acceptance limits.
Ⓠ How should TK-3E 177313-02-02-00 be used to separate runout from channel error?
First establish static linearity, then run several dynamic amplitudes. A repeatable mechanical pattern tied to target rotation differs from a fixed electrical offset or gain error.
Ⓠ Does TK-3E 177313-02-02-00 require the machine's extension cable during a bench check?
Use the complete installed electrical-length combination when validating the loop. Substituting cable length can change the response and defeats an end-to-end comparison.
Ⓠ What does a good TK-3E 177313-02-02-00 dynamic result prove?
It demonstrates that the assembled chain and channel track a controlled displacement input at the test condition; it does not reproduce every shaft material, temperature or mounting effect in service.