The complete code defines a combined protection relay
▦
3 Voltage + frequency
0 10–250 V range
E English interface
HI High auxiliary supply
00 Standard finish
The HI auxiliary option accepts 110–250 Vdc or 110–230 Vac, with published operating ranges of 88–300 Vdc and 88–264 Vac.
02 / PROTECTION WORKSPACE
Voltage, frequency and event analysis in one relay
⚡
Voltage elements
Four delayed phase under/overvoltage elements and two delayed ground overvoltage elements.
∿
Frequency elements
MIV II 3000 provides two frequency elements configurable for underfrequency or overfrequency.
◎
Sequence insight
Up to 24 time-tagged events plus a 24-cycle oscillography record at eight samples per cycle.
🖥 Local operation
A 16 × 2 LCD, five-key keypad and six status LEDs support front-panel work; four LEDs are configurable.
▦ Rack profile
The draw-out housing occupies one quarter of a 19-inch rack and has a 4U height.
✓ Setting workflow
Pickup, delay, output assignment and blocking logic can be coordinated for the protected bus or feeder.
AMIKON · SINCE 2005
Automation spares for planned work and urgent recovery
Support across PLC, HMI, DCS, industrial PC and drive platforms with responsive service and global dispatch.
✓ Hard-to-find parts · ✈ Fast dispatch · ☎ Responsive support
03 / TECHNICAL PARAMETERS
Operating ranges and fixed resources
⚙
Voltage pickup
10.0–250.0 V; 0.1 V increments
Frequency pickup
42.00–67.50 Hz; 0.01 Hz increments
Element timers
0.00–600.00 s
Consumption
15 W maximum
Digital I/O
2 inputs; 6 Form C outputs
Serial link
Modbus RTU; 300–19,200 bps
Event capacity
24 events; 1 ms time tags
Oscillography
24 cycles; 8 samples/cycle
Front protection
IP52
Operating temperature
−20 to +60 °C
04 / BUYER FAQ
Application details that affect a correct relay replacement
QWhich protection mix does GE MIVII3000E00HI00 provide?
A · It combines voltage and frequency functions: phase under/overvoltage, ground overvoltage, voltage unbalance and two frequency elements.
QWhat auxiliary supply is encoded by HI in GE MIVII3000E00HI00?
A · HI denotes the high-range supply: 110–250 Vdc or 110–230 Vac, with operating ranges of 88–300 Vdc and 88–264 Vac.
QCan GE MIVII3000E00HI00 replace a MIV II 1000 or 2000 without a settings review?
A · No. The 1000, 2000 and 3000 variants have different protection mixes; input range, logic, outputs and settings must be recreated for the intended application.
QWhat historical data can GE MIVII3000E00HI00 retain after an operation?
A · It can retain up to 24 time-tagged events and one 24-cycle oscillography record captured at eight samples per cycle.
QHow should communications be checked when replacing GE MIVII3000E00HI00?
A · Preserve the Modbus RTU address, baud rate and serial settings, then verify both front RS-232 service access and the rear RS-485 network path used by the site.