AMIKON LIMITED
We'll get back to you as soon as possible.
Place of Origin:
USA
Brand Name:
Honeywell
Model Number:
TMG740-3-MOD-43-35
| 220 / 240 V AC Supply |
MOD 43-35 Timing program |
08218U Order identity |
| Match the complete burner sequence, voltage and detector arrangement Sales Manager: Miya Zheng |
EMAILWHATSAPP |
|
A
Burner formatsSingle-stage, two-stage, multi-stage and modulating arrangements. |
B
Fuel arrangementsGas, oil and dual-fuel forced-draught burners. |
C
Flame supervisionIonisation, infrared or ultraviolet detection. |
| SUPPLY | 220 / 240 V AC, -15% to +10% | 01 |
| FREQUENCY | 50 Hz; operating range 40-60 Hz | 02 |
| CONSUMPTION | Approx. 15 VA | 03 |
| FLAME INPUT | Ionisation, IRD infrared or UVZ ultraviolet | 04 |
| AMBIENT | -20 to +60 degrees C | 05 |
| SUBBASE | 70205 wiring socket, separate identity | 06 |
| 01 Heat demand |
→ | 02 Pre-purge |
→ | 03 Ignition |
→ | 04 Pilot prove |
→ | 05 Main flame |
| 12-MONTH WARRANTY Coverage for supplied parts. |
RETURN SUPPORT Contact within 7 days; keep eligible items in original condition. |
EMAILWHATSAPP |
| Can TMG740-3-MOD-43-35 replace another MOD version?
No automatic substitution. Timing, voltage, wiring, stages and detector arrangement must correspond.
|
Which detectors suit TMG740-3-MOD-43-35?
Use the installed ionisation, IRD infrared or UVZ ultraviolet arrangement assigned to the burner.
|
| Is the 70205 socket included with TMG740-3-MOD-43-35?
The subbase is separate; define whether the scope is controller-only or controller plus socket.
|
Why must TMG740-3-MOD-43-35 retain MOD 43-35?
The suffix fixes purge, ignition, valve-release and flame-safety timing.
|
| Can a 110/120 V TMG740-3-MOD-43-35 replace the 220/240 V execution?
No direct substitution should be made. Supply voltage and the complete burner circuit must match.
|
|
| 5502DAL | 020-884 | TH53T/O-MDOT | 130B7492 |
| NetAXS-123 NX1P | QSNE-2DAL-D | 58006020 | CC-TAIX01 |
| PN:233-1680-05 | ABS-2D | METSEPM89RD96 | 4100-9512 |
| FLX-010 | 7VR9502/BB | SCI0410S | 2074029-D0 |
| OLS2 LS2D OPM4-3D | GE U4000 | 01984-1137-0001 | EVZS8O4MM-BI |
| Z031.695/06 | 2182-215 | CTY-RS-SAI16-KS | MI001 PTB010 |
| BWBC1 BC1 | 130B1906 | VLC-16160Z-KH | VT-MODEM-5-WW |
| PCS095.M | TL6174.00.00 | CH-HRIO8-D9 | 3G/HD |
| 08700151-002 | EX95160-00B | ELDS4-1-DIN | EY-CM721F010 |
| 160/90 | LQSE-4T10-D | 1007-101 | BIP-1500 |
|
PROGRAM 43-35 / BURNER CONTROL
Request TMG740-3-MOD-43-35 AvailabilitySales Manager: Miya Zheng |
sales@amikon.cn WhatsApp: 86-18020776792 |
Send your inquiry directly to us