AMIKON LIMITED
We'll get back to you as soon as possible.
Place of Origin:
USA
Brand Name:
Bently Nevada
Model Number:
330180-91-05
|
3300 XL
9.0 m
DIN RAIL
OPTION
05 |
BENTLY NEVADA PROXIMITOR SENSOR
330180-91-05
3300 XL 5 mm / 8 mm Signal Conditioner
Converts the probe signal into a voltage proportional to shaft-to-probe distance for vibration, position, phase and speed measurement.
|
|
01 / PRODUCT ROLE
The electrical center of a non-contacting measurement loop.
|
The 3300 XL 8 mm transducer system combines a proximity probe, extension cable and Proximitor sensor. It produces an output voltage directly proportional to the distance between the probe tip and the conductive target.
The same loop measures static shaft position and dynamic vibration, and also supports Keyphasor phase and speed duties on fluid-film bearing machinery.
|
| Static position Shaft location and axial movement. |
Dynamic vibration Relative shaft motion at the bearing. |
Phase and speed Keyphasor timing and rotational data. |
| ORDER CONFIGURATION | |
| Order code | 330180-91-05 |
| Total system length | 9.0 m |
| Mounting | DIN rail |
| Approval option | 05 / multiple agency approvals |
| SIGNAL PERFORMANCE | |
| Nominal sensitivity | 7.87 V/mm (200 mV/mil) |
| Linear range | 2.0 mm (80 mil) |
| Output resistance | 50 ohm |
| Supply sensitivity | Less than 2 mV output change per supply volt |
| POWER AND ENVIRONMENT | |
| Supply without barriers | -17.5 to -26 Vdc |
| Maximum current consumption | 12 mA |
| Operating temperature | -52 to +100 degrees C |
| Storage temperature | -52 to +105 degrees C |
|
03 / SYSTEM MATCH
The probe lead and extension cable must total 9.0 m.
|
Code 91 identifies both the calibrated total length and DIN mounting. Replacing only the Proximitor sensor does not correct an incorrectly matched probe and extension-cable combination. |
|
01
Probe leadFirst cable section |
02
Extension cableCompletes the run |
9 m
Matched lengthRequired by code 91 |
| SpringLoc terminals | Electrical isolation at base | High RFI/EMI immunity |
| 01 | Can 330180-91-05 replace a 5 m Proximitor sensor? | No. Code 91 is calibrated for a 9.0 m probe-plus-extension-cable system. Total system length must remain matched. |
| 02 | Which probes are compatible with 330180-91-05? | It accepts a compatible 3300-series 5 mm, 3300 8 mm or 3300 XL 8 mm probe with the matching extension cable. |
| 03 | What does option 05 mean on 330180-91-05? | It denotes multiple agency approvals. The complete installed loop must still follow the applicable hazardous-area conditions. |
| 04 | Can 330180-91-05 replace a panel-mount unit? | Code 91 is DIN rail mount. A panel installation requires the correct mounting option rather than an improvised adapter. |
| 05 | When should 330180-91-05 scaling be checked in the field? | Check installed gap and scale when target material differs from AISI 4140 steel or when the loop contains unmatched components. |
| GI357.Z53 | SGDV-5R4D11A | BMXCPS3020H | 703-1178 |
| IC200UDR005-BG | OEE-1 | TAP-601-AAAA | ADV551-P50 |
| 72752-01K | PCO3000BL0 | S4000T/31180-2 | CP40000000 |
| J120-361 | MI-585162-2 DI-9001 | 5R4D11A | MV1417 |
| Z035.263/04 | MS-UD650 | 031-01095-002 | FVR46 |
| SAI143-S03 | GW 90821 | 300E | FR-2RU-10-2 |
| XF830A | inBio260 | LSC-X21-02M | AAI143-H53 |
| POWTOR0002 | JASP-WRCA01B | S1BB4D-06 | 868-1-20 |
| 5073523EQ | 04079200 | MMI20013514 | PCO3000BL0 Rev.2.011 |
| uh50-g36c-ae00-f | ADV551-P50 | LSC-X21-02M | PCO3000BL0 |
|
PROBE / CABLE / MOUNTING CODE
Request 330180-91-05 AvailabilitySales Manager: Miya Zheng |
sales@amikon.cn WhatsApp: 86-18020776792 |
Send your inquiry directly to us