Siemens 6ES7431-7QH00-0AB0 SM 431 Analog Input Module – AI 16 × 16 Bit

Siemens 6ES7431-7QH00-0AB0 SM 431 Analog Input Module – AI 16 × 16 Bit

16-Channel Analog Input

16-Bit Resolution

6ES7431-7QH00-0AB0 pdf

Place of Origin:

Germany

Brand Name:

Siemens

Contact Us
Request A Quote
Product Details
Quotation Time:
Quick Quote Within 24 Hours
MOQ:
1 Piece
Shipping:
TNT, DHL, FedEx, EMS, UPS
Highlight:

16-Channel Analog Input

,

16-Bit Resolution

,

6ES7431-7QH00-0AB0 pdf

Payment & Shipping Terms
Minimum Order Quantity
1
Packaging Details
Brand new and original
Delivery Time
2-3 work days
Payment Terms
T/T
Supply Ability
in stock
Product Description
Siemens SIMATIC S7-400

6ES7431-7QH00-0AB0

SM 431 · AI 16 × 16 Bit · Analog Input Module

Analog input module for S7-400 automation systems, with configurable measurement methods and diagnostic functions.

Request a Quote Send the part number and your application details.

Technical Specifications

Model-specific Siemens reference data
6ES7431-7QH00-0AB0 / SM 431 TECHNICAL DATA · SECTION 5.23
01 / Product Identification & Channel Architecture
Manufacturer Siemens
Product family SIMATIC S7-400
Module designation SM 431 analog input module
Module type AI 16 × 16 Bit
Article number 6ES7431-7QH00-0AB0
Measurement principle Integrating
Total analog inputs 16
Voltage / current / thermocouple 16 inputs
Resistance / RTD measurement 8 inputs
Resolution 16 bit
Measurement methods Voltage, current, resistance, resistance thermometer and thermocouple
02 / Voltage & Current Input Ranges
Voltage ranges ±25 mV, ±50 mV, ±80 mV, ±250 mV, ±500 mV
Additional voltage ranges ±1 V, ±2.5 V, ±5 V, 1–5 V, ±10 V
Voltage input resistance 1 MΩ
Current ranges ±5 mA, ±10 mA, ±20 mA, 0–20 mA, 4–20 mA
Current input resistance 50 Ω
2-wire current transmitter burden Maximum 750 Ω
Current transmitter connection 2-wire and 4-wire transducers
Maximum voltage input limit 18 V continuous; 75 V for 1 ms, duty ratio 1:20
Maximum current input limit 40 mA
03 / Resistance, RTD & Thermocouple Measurement
Resistance ranges 0–48 Ω, 0–150 Ω, 0–300 Ω, 0–600 Ω, 0–6000 Ω
Usable upper value in 6000 Ω range 5000 Ω
Resistance sensor wiring 2-wire, 3-wire and 4-wire
RTD wiring 3-wire and 4-wire
Supported resistance thermometers Pt100, Pt200, Pt500, Pt1000, Ni100 and Ni1000
Thermocouple types B, E, J, K, L, N, R, S, T and U
RTD / TC input resistance 1 MΩ
Resistance measurement current Typical 1.67 mA
Temperature compensation Parameterizable
External compensation Pt100 or compensation socket
Dynamic reference temperature Supported
Characteristic linearization Parameterizable for supported thermocouple and RTD types
04 / Conversion, Timing & Accuracy
Integration time Parameterizable
Basic conversion time 6 / 20.1 / 23.5 ms
Integration time settings 2.5 / 16.7 / 20 ms
Additional wire-break monitoring time 4.3 ms
Additional resistance measurement time 12 / 40.2 / 47 ms
Interference frequency suppression 400 / 60 / 50 Hz
Measured-value smoothing Parameterizable, 4 stages
Linearity error ±0.01% of input range
Temperature error ±0.004% of input range per K
Repeat accuracy at 25°C ±0.1% of input range
Voltage operational error limit Typically ±0.3%; range-dependent values apply
Current operational error limit ±0.3% of input range
RTD operational error limit ±0.4% of input range
Thermocouple operational error Depends on thermocouple type
Crosstalk between inputs Greater than 70 dB
Shielded cable length Maximum 200 m; 50 m for thermocouples and ranges ≤80 mV
Thermocouple Operational Error Values
Type B ±11.5 K
Type R ±7.3 K
Type S ±8.3 K
Type T ±1.7 K
Type E ±3.2 K
Type J ±4.3 K
Type K ±6.2 K
Type U ±2.8 K
Type L ±4.2 K
Type N ±4.4 K
05 / Power Supply & Electrical Isolation
Load voltage L+ 24 V DC; required for supplying 2-wire transmitters
Current from L+ Maximum 400 mA with 16 connected, fully controlled 2-wire transmitters
Current from 5 V backplane bus Maximum 700 mA
Transmitter supply output Short-circuit proof
Transmitter supply current Maximum 50 mA
Typical power loss 4.5 W
Analog section / CPU Potential separation
Channel-to-channel isolation No
Isolation from backplane bus Yes
Isolation from load voltage L+ Yes
Specified potential difference 60 V DC / 30 V AC, according to the module data
06 / Diagnostics, Interrupts & Mechanical Data
Configurable diagnostics Yes
Diagnostic information Readable
Diagnostic interrupt Parameterizable
Limit value alarm Parameterizable
Hardware interrupt Parameterizable
Diagnostic functions Wire break, reference-channel error, underflow and overflow
Short-circuit to M diagnostics Configurable for 2-wire current transducer measurement
Internal fault indicator Red INTF LED
External fault indicator Red EXTF LED
Substitute values Not connectable
Width × height × depth 25 × 290 × 210 mm
Approximate weight 500 g

Reference: Siemens S7-400 Automation System Module Data, section 5.23, article number 6ES7431-7QH00-0AB0.

Configuration & Installation Notes

Hardware selection · STEP 7 setup · commissioning

Measuring-Range Module & STEP 7 Setup

The operating mode is selected through the measuring-range modules on the SM 431 and the measurement-type parameters in STEP 7. Each measuring-range module serves a pair of channels; the physical selector position and software configuration must therefore be planned together.

  • Set the measuring-range modules to the required signal type and range.
  • Configure the corresponding measurement method for each channel in STEP 7.
  • Check the paired-channel restrictions for 0/1, 2/3, 4/5, 6/7, 8/9, 10/11, 12/13 and 14/15.
  • For unused channels, set the measuring method to Deactivated; the measuring-range module should be set to position A.

Wiring & Commissioning Checks

  • Confirm the selected 2-wire or 4-wire current transmitter connection.
  • For 2-wire current transmitters, provide 24 V DC at the L+ and M front-connector terminals.
  • Verify the RTD type, thermocouple type and reference-junction arrangement.
  • Observe the cable-length limit for the selected measuring method.
Before replacement or recommissioning, compare the installed module's physical measuring-range settings with the project configuration and channel assignments in STEP 7. Check the module's 48-pin front-connector wiring against the Siemens connection diagram.

Application & Failure Scenarios

Process measurement · control feedback · maintenance

Process Signal Acquisition

In SIMATIC S7-400 installations, this module receives analog process signals from field instrumentation. Its measurement capabilities are relevant to systems that monitor process variables through voltage and current transmitters, resistance sensors, resistance thermometers and thermocouples. These inputs can form part of machine feedback, temperature supervision and process monitoring functions.

Typical Maintenance Triggers

01INTF or EXTF fault indication on the module.
02Missing, unstable or implausible values from a field measurement channel.
03Wire-break, reference-channel, underflow or overflow diagnostic events.
04Suspected failure of an analog input channel or the module itself.
When analog feedback is unavailable or unreliable, dependent monitoring, alarms and control sequences may be affected. The operational impact depends on the plant's instrumentation, control logic and system architecture.

Supply & Warranty

Order handling & after-sales coordination
Inspection & Testing Order-specific inspection and test arrangements confirmed before dispatch.
Protective Packaging Protective packing for industrial electronic components.
DOA / Returns Report arrival faults or transit damage promptly with photos and order details.
12-Month Warranty Subject to the agreed quotation and warranty terms.

Global Industrial Sourcing

Part identification · international supply · order coordination
AMIKON industrial automation parts sourcing and service team
AMIKON · GLOBAL INDUSTRIAL TRADE Connecting Automation Parts with Global Industry.
INDUSTRIAL AUTOMATION   /   GLOBAL SOURCING

Supporting Maintenance and Procurement Worldwide

AMIKON works with industrial maintenance and procurement teams to source automation and control-system components. From part-number identification to order communication and shipment coordination, our focus is on practical support for industrial supply requirements.

Product Enquiry

Talk to Our Sales Team

Contact Miya Zheng for product and order enquiries.

DIRECT CONTACT · MIYA ZHENG sales@amikon.cn WhatsApp +86 180 2077 6792
RFQ details: Part Number  ·  Quantity  ·  Destination  ·  Required Date  ·  Machine/System Model

Frequently Asked Questions

6ES7431-7QH00-0AB0
1. Which sensor types can this SM 431 module measure?

The documented sensor types include voltage and current signals, resistance sensors, Pt100/Pt200/Pt500/Pt1000 and Ni100/Ni1000 resistance thermometers, and thermocouple types B, E, J, K, L, N, R, S, T and U.

2. Does the module support 4–20 mA transmitters?

Yes. The documented current ranges include 4–20 mA. Both 2-wire and 4-wire current transducers are supported; 2-wire transmitters require a 24 V DC supply at the L+ and M front-connector terminals.

3. How are the input channels configured?

The measuring-range modules on the hardware and the measuring-type parameters in STEP 7 determine the measurement setup. Adjacent channels have specified pairing restrictions, so the hardware positions and software parameters must be checked together.

4. What diagnostic functions are available?

The module supports configurable diagnostics, diagnostic interrupts, limit alarms and hardware interrupts. It also provides INTF and EXTF fault LEDs, and configurable checks including wire break, reference-channel error, underflow and overflow.