Siemens
Siemens 6ES7952-1KM00-0AA0 is a SIMATIC S7-400 memory card featuring a long design and 4 Mbytes of Flash-EPROM storage. It serves as non-volatile CPU load memory for the S7-400 user program.
Flash-EPROM retains stored program data when power is removed and when the card is outside the CPU. Its memory technology and capacity are important identification points when maintaining an established S7-400 installation.
| Manufacturer | Siemens |
| Product Family | SIMATIC S7 |
| Order Number | 6ES7952-1KM00-0AA0 |
| Product Type | Memory Card |
| Memory Format | 5V Flash-EPROM |
The user program is prepared on a programming device using STEP 7. The program can be transferred to the Flash memory card through the supported programming procedure.
The 4 Mbyte Flash-EPROM card stores the user program in non-volatile memory. Stored data is retained without backup voltage, including when the card is removed from the CPU.
The memory card is used as CPU load memory in the S7-400 system, providing storage for the controller user program.
The user program can be loaded to the Flash card with the CPU in STOP through STEP 7, or loaded offline using a programming device or programming adapter.
Used in Siemens SIMATIC S7-400 automation systems as Flash load memory for storing the CPU user program. It is relevant to control cabinets and established PLC installations where non-volatile program storage is required.
Maintenance teams may search for this card when an installed memory card is missing, damaged, unreadable or needs replacement during PLC memory maintenance. An unavailable program-storage medium can delay program restoration and extend controller or machine downtime.
The S7-400 platform uses RAM and Flash memory cards. This catalog number identifies a Flash-EPROM card. Check the installed card type and the CPU requirements before sourcing a replacement.
Verify that the 4 Mbyte capacity is appropriate for the installed application and existing program storage requirements.
The user program can be loaded to a Flash card through STEP 7 with the CPU in STOP, or loaded offline using a programming device or programming adapter.
Flash memory retains stored data when power is removed or the card is taken out of the CPU. Keep a verified program backup and follow the applicable CPU manual during replacement work.
It is a 4 Mbyte Flash-EPROM memory card for the Siemens SIMATIC S7-400 automation system. It serves as non-volatile CPU load memory for the user program.
It is a Flash-EPROM card. Its stored data is retained without backup voltage, including when the card is removed from the CPU.
The specified memory capacity is 4 Mbytes. The card uses the long design and is identified as a 5V Flash-EPROM memory card.
This model is identified as an S7-400 memory card. Do not assume compatibility with other SIMATIC PLC families or memory-card formats without checking the relevant CPU requirements.
Please provide the complete part number, quantity, destination, required date and machine/system model. A photo of the installed card label can also help with identification.