AMIKON LIMITED
We'll get back to you as soon as possible.
Place of Origin:
Germany
Brand Name:
Siemens
The Siemens 6EP1333-1LB00 belongs to the SITOP PSU100L product line. It is a primary-clocked, single-phase AC power supply with an electronically regulated, isolated DC output.
This model is rated for 24 V DC and 5 A, with a typical active output power of 120 W. Its output voltage can be adjusted by the front potentiometer, and a green LED indicates the 24 V output status.
The PSU100L series is designed for basic industrial power supply requirements. The documented functions include natural-convection cooling, overload and short-circuit protection, and parallel connection.
Model-specific technical data for 6EP1333-1LB00. Each specification sheet is grouped by function for quicker reference.
| Manufacturer | Siemens |
| Order Number | 6EP1333-1LB00 |
| Product Family | SITOP PSU100L |
| Product Type | Stabilized power supply |
| Input Phase | Single-phase AC |
| Rated Input Voltage | 120 / 230 V AC, selectable |
| Input Voltage Range | 93–132 V AC / 187–264 V AC |
| Rated Input Frequency | 50 / 60 Hz |
| Input Frequency Range | 47–63 Hz |
| Input Current at 120 V AC | 2.1 A |
| Input Current at 230 V AC | 1.15 A |
| Maximum Inrush Current at 25°C | 32 A |
| Mains Buffering at Rated Output Current | 20 ms minimum |
| Output Voltage | 24 V DC |
| Rated Output Current | 5 A |
| Output Current Range | 0–5 A |
| Typical Active Output Power | 120 W |
| Output Voltage Adjustment Range | 22.8–26.4 V |
| Output Voltage Adjustment | Front-mounted potentiometer |
| Total Static Tolerance | ±3% |
| Static Line Regulation | Approx. ±0.1% |
| Static Load Regulation | Approx. ±0.5% |
| Maximum Residual Ripple | 150 mV peak-to-peak |
| Typical Residual Ripple | 50 mV peak-to-peak |
| Maximum Spikes | 240 mV peak-to-peak, 200 MHz bandwidth |
| Typical Spikes | 150 mV peak-to-peak, approx. 20 MHz bandwidth |
| Maximum Starting Delay | 1.5 s |
| Typical Starting Delay | 150 ms |
| Typical Voltage Rise Time | 500 ms |
| Maximum Voltage Overshoot | Approx. 4% |
| Efficiency at Rated Output | Approx. 86% |
| Power Loss at Rated Output | Approx. 17 W |
| Dynamic Line Regulation | Max. 0.3% |
| Dynamic Load Regulation | Max. 3% (10/90/10% load change) |
| Typical Load-Step Settling Time | 0.4 ms, 10–90% / 90–10% |
| Maximum Capacitive Load | 2 mF/A |
| Output Overvoltage Protection | Below 33 V |
| Typical Current Limitation | 5.25 A |
| Output Protection | Overload and short-circuit protection |
| Short-Circuit Response | Electronic trip with automatic restart |
| Parallel Connection | Permitted for increased power rating; up to 2 units |
| Protection Class | Class I |
| Degree of Protection | IP20 |
| Isolation / Output | Isolated SELV output voltage |
| Input Fuse | T 3.15 A / 250 V, integrated and not accessible |
| Recommended Input Protection | Miniature circuit breaker, characteristic C, 6 A |
| Input Terminals | L1, N and PE; one screw terminal each |
| Output Terminals | + and −; two screw terminals each |
| Mounting | DIN rail, EN 60715 TH35-15/7.5 |
| Dimensions (W × H × D) | 50 × 125 × 120.3 mm |
| Weight | Approx. 0.5 kg |
| Recommended Installation Position | Vertical, input and output terminals at the bottom |
| Required Clearance | At least 50 mm above and below; no lateral clearance required |
| Installation Manual | SITOP PSU100L, C98130-A7603-A1-2-7629, 08/2016 |
| Operating Temperature | 0 to +60°C, with derating above 45°C |
| Cooling | Natural convection |
| EMC Emitted Interference | EN 55022 Class A |
| EMC Immunity | EN 61000-6-2 |
| Approvals | CE; cULus Listed (UL 508, CSA C22.2 No. 107.1) |
Siemens states that technical data apply at rated input voltage, rated load and 25°C ambient temperature unless otherwise specified.
The unit is designed for installation inside a housing or control cabinet accessible only to qualified personnel. It mounts on a standard EN 60715 TH35-15/7.5 rail.
For the standard mounting position, install the unit vertically with the input and output terminals facing downward. Maintain at least 50 mm clearance above and below the power supply to support cooling.
The AC line connection uses L1, N and PE. The DC load connects to the positive and negative output terminals. Output cables must be sized for the maximum output current and protected by suitable fusing.
The 6EP1333-1LB00 is used as a 24 V DC power source in industrial control cabinets and electrical systems. Its SITOP PSU100L design is intended for basic industrial power supply requirements, providing DC power to connected control and field loads.
Maintenance teams may search for this unit when a 24 V DC supply is missing, unstable or unable to support connected loads, or when the power supply shows an abnormal status. Loss of control power can affect connected automation equipment and interrupt machine or process operation while the supply circuit is inspected and restored.
The front green LED is marked “24 V O.K.” Siemens documents that the LED lights green during normal operation when the output voltage is above 20 V ±0.5 V. The LED is off when no supply voltage is present.
The PSU100L output is designed to withstand no-load, overload and short-circuit conditions. For this 5 A model, the manual describes electronic tripping with automatic restart under short-circuit conditions. If an overload remains, the output voltage and current may be reduced and the unit may repeatedly restart.
Siemens SiePortal lists 6EP1333-1LB00 as Phase Out Announce. Confirm the required quantity, project timing and installation requirements when planning procurement or maintenance replacement. No direct successor or drop-in replacement is stated here.
It provides a nominal output of 24 V DC at 5 A, with a typical active output power of 120 W.
It supports selectable 120 V AC or 230 V AC input. The documented input ranges are 93–132 V AC and 187–264 V AC respectively.
Yes. The front potentiometer allows adjustment from 22.8 V to 26.4 V. The factory setting is 24 V.
Check the green “24 V O.K.” LED. Siemens specifies that it lights during normal operation when the output voltage is above 20 V ±0.5 V.
Verify the AC input selection, required circuit protection, DIN rail mounting position, ventilation clearance and output wiring. Installation must be performed by qualified personnel with the supply isolated.
Inspection and testing arrangements can be confirmed with the quotation.
Protective packaging is arranged for shipment.
Cases are reviewed against order records and agreed return terms.
12-month warranty, subject to quotation terms and agreed coverage.
AMIKON supports industrial spare parts sourcing with quotation coordination, product communication and shipment arrangements. We work with maintenance and procurement teams to clarify part requirements and coordinate supply requests..
Send your inquiry directly to us