logo
Home > Products > GE Mark VIe Controller >
GE 336A4940CTP2 Four-slot CPCI controller rack with dual power-supply positions

GE 336A4940CTP2 Four-slot CPCI controller rack with dual power-supply positions

GE 336A4940CTP2

General Electric UR9UH

UR9UH CPU

Place of Origin:

USA

Brand Name:

General Electric

Model Number:

336A4940CTP2

Contact Us
Request A Quote
Product Details
Highlight:

GE 336A4940CTP2

,

General Electric UR9UH

,

UR9UH CPU

Payment & Shipping Terms
Minimum Order Quantity
1
Packaging Details
Brand new and original
Delivery Time
2-3 work days
Payment Terms
T/T
Supply Ability
in Stock
Product Description
GE MARK VIe / CPCI CONTROLLER HARDWARE
336A4940CTP2
Four-slot CPCI controller rack with dual power-supply positions
Configuration P2: two power-supply positions, two bulk-power inputs, controller backplane and forced-air cooling.
CPCI CONTROLLER RACK   /   P2
SLOT
1
SLOT
2
SLOT
3
SLOT
4
POWER SUPPLY A POWER SUPPLY B
Check rack condition, fan assembly and power configurationSales Manager: Miya Zheng EMAIL WHATSAPP
01
Rack Function
CONTROLLER SUPPORT / POWER DISTRIBUTION
The GE 336A4940CTP2 is the P2 version of the four-slot CPCI rack used with compatible Mark VIe UCSx and UCCx controller arrangements. It houses controller hardware, accepts two CPCI power supplies and provides the backplane connection used for controller and fan power.

Two incoming bulk-power connectors support the dual-supply arrangement. Each installed CPCI power supply converts incoming power into the regulated voltages required by the rack.
4CPCI slots 2Power positions
2Power inputs 300Linear ft/min
BULK INPUTSTwo incoming feeds > CPCI SUPPLIESDual positions > BACKPLANE+/-12 V, 5 V, 3.3 V
02
Technical Configuration
P2 RACK / ENVIRONMENTAL LIMITS
RACK AND POWER
Catalog number 336A4940CTP2
Rack format Four-slot CPCI
Power positions Two
Power inputs Two
Backplane outputs +/-12 V, 5 V, 3.3 V
Front switch Not fitted on P2
OPERATING ENVIRONMENT
Operating temperature 0 to +65 degrees C
Storage temperature -40 to +85 degrees C
Humidity 5 to 95%, non-condensing
Operating altitude 0 to 10,000 ft / 3,000 m
Cooling airflow 300 linear ft/min
Enclosure level NEMA 1 / IP20
03
Replacement Checkpoints
MECHANICAL / POWER / COOLING / SAFETY
P1 OR P2Confirm dual-supply P2 configuration; P1 and P2 use different shutdown methods. BACKPLANEInspect guides, connectors and controller seating for damage. FAN PATHConfirm fan operation and the required cooling airflow. ISOLATIONP2 has no front switch; plan safe upstream isolation.
AMIKON Supply Service
INDUSTRIAL PARTS / URGENT SUPPORT
20 YEARSIndustrial automation sourcing experience.
PRE-DISPATCH CHECKPart number, visible condition and packing confirmation.
FAST RESPONSESupport for time-critical requirements.
12-month warranty and return supportContact us within 7 days if a problem is found. Keep the unit in original condition and provide a clear return reason. Refund or replacement can be arranged after receipt and inspection. Return shipping is handled by the buyer. sales@amikon.cn86-18020776792
04
336A4940CTP2 Purchase FAQ
SITE CHECKS BUYERS OFTEN MISS
How can a buyer distinguish 336A4940CTP2 from the P1 rack before shutdown?
Check the label and power arrangement. P2 has two supply positions and two incoming connections; P1 has one of each and a front on/off switch.
Which items should be included when quoting a complete 336A4940CTP2 assembly?
Clarify whether the requirement covers only the rack or also the fan assembly, both supplies, power plugs, mounting hardware and controller modules.
How should cooling condition be assessed before installing 336A4940CTP2?
Inspect fan operation, airflow direction, blocked vents and enclosure temperature. The rack requires 300 linear ft/min airflow.
Which shutdown detail is critical when replacing 336A4940CTP2?
P2 has no front switch. Power is removed by ejecting the supplies, disconnecting incoming plugs or using a remote disconnect under the approved site procedure.
Which acceptance checks should follow 336A4940CTP2 installation?
Verify both incoming feeds, both supply status indications, fan operation, regulated backplane voltages, controller seating, controller startup, network communication and stable operation under normal cabinet thermal load.
05
Recommended Models
ADDITIONAL INDUSTRIAL PART NUMBERS
KJ3241X1-BK1 6ES7677-2DB42-0GB0 BGS-V80CN PM592-ETH-XC
2094-BM03-M CNGP431FN-EXK 3500/92-04-01-01 TLS1CARD
IS230TCATH1A SC1-1/2T1.000B 2093-AM03 KC3030X1-BK2
A-751-116-9B PLX32-EIP-PND ACS580-01-07A3-4 UHMT1
330910-00-24-10-01-CN F-2500-284-0550 X20CP3585 GHGR 31.7-3
IS220PDIAH1A 2093-AM05 SM560-S-FD-1-XC 9375-12UNJ-3B
6GK7242-5DX30-0XE0 DW-AS-501-04 3500/33-SIL2-03-01 2VBQ3-4N
KJ4006X1-BD1 2071-AP0 3HAC037835-001 TTEL25.4-2T17
IC693APU301M PLN-10X1.5 F8627X TLRP-3062L
8I0IF248.300-1 6ES7241-1AH32-0XB0 SNAP-AITM PR6426/000-130
Check 336A4940CTP2 availability
Send rack-label photos, required included parts, quantity, destination and maintenance deadline.
Sales Manager: Miya Zheng   |   sales@amikon.cn   |   +86 180 2077 6792

Send your inquiry directly to us