AMIKON LIMITED
We'll get back to you as soon as possible.
Place of Origin:
USA
Brand Name:
General Electric
A turbine termination board used in the Mark VI control architecture for turbine speed pickup signals, shaft monitoring, generator and bus voltage sensing, and generator-breaker synchronization circuits.
How the board fits into the turbine control system
TTUR provides field termination for selected turbine-control signals and connects those circuits with the associated control and protection hardware. Its interfaces include magnetic speed pickups, shaft voltage and current monitoring, generator and bus potential-transformer inputs, and the main generator breaker close circuit.
For automatic synchronization, the generator and bus voltage signals are evaluated alongside turbine speed and synchronization logic. Breaker closure depends on the required internal relay conditions and external permissives; the terminal board alone does not determine whether the generator is ready to connect to the bus.
Board identification and system-level interface details
GE Mark VI turbine control architecture
The Mark VI system guide gives a pulse-rate range of 2 Hz to 14 kHz and an input sensitivity of 27 mV peak for the documented MPU interface.
The system-level specification lists 0.05% of reading for MPU pulse-rate accuracy. Confirm applicability to the installed hardware and signal path before using this value for acceptance testing.
The synchronization interface uses potential-transformer secondary signals. The documented typical nominal value is 115 V AC RMS; verify the actual plant circuit and approved wiring before testing.
The documented TTUR breaker interface uses a nominal 125 V DC breaker-coil supply. Verify the installed breaker circuit rating, wiring and isolation arrangements before maintenance.
| Terminal range | Signal or circuit | Identification notes |
|---|---|---|
| TB points 1–8 | Generator breaker close circuit and associated relay contacts | Includes the breaker interface and synchronization relay paths. |
| TB points 17–20 | Generator and bus voltage signals | Used by the synchronization interface. |
| TB points 21–24 | Shaft voltage and shaft current signals | Confirm the exact terminal assignment against the applicable wiring diagram. |
| TB points 25–48 | Magnetic speed pickup signal pairs | Signal pairs are allocated to the documented T, S and R paths. |
Works with the VTUR automatic synchronization function to provide the associated breaker-close relay condition.
Provides a permissive condition tied to the turbine control sequence and application logic.
Provides a synchronization-check relay function associated with the protection-side logic.
The documented architecture uses jumper-selectable relay driver arrangements for Simplex or TMR applications. The correct jumper positions must match the installed control configuration.
The generator breaker close circuit requires the appropriate relay conditions and external permissives. In TMR configurations, the relevant control paths use redundant controller signals and voting logic. Relay status, breaker feedback and circuit supply should be checked as separate diagnostic points.
Practical checks for common turbine-control symptoms
Check the pickup device, cable condition, terminal pair, shield termination and corresponding control diagnostics. Confirm whether the issue affects one channel or multiple redundant paths before attributing the fault to the board.
Review generator and bus voltage measurements, frequency and phase differences, synchronization permissives, relay feedback and external interlocks. A failed close permissive does not by itself identify a defective TTUR board.
Check the specified breaker-coil supply, K25/K25P/K25A relay states, external permissives and 52G feedback according to the approved troubleshooting procedure. Isolate the breaker close circuit before any functional test.
Inspect the sensor circuit, field wiring and signal termination, then compare the indicated measurement with the system's diagnostic data. Confirm the fault source before replacing hardware.
For technical verification and maintenance planning
The GE Mark VI Control System Guide, GEH-6421 series, covers the TTUR terminal board architecture, speed pickup inputs, synchronization relays, terminal connections and breaker-interface checks. Use the applicable volume and revision together with the plant's approved wiring diagrams to verify the installed configuration.
Search phrase: IS200TTURH1B manual PDF
Confirm the supplied item's condition before dispatch
Part number, available condition information and the quoted supply scope are checked against the order details.
Available inspection or testing and protective packaging arrangements are confirmed for the specific quoted item.
Report suspected arrival damage or a dead-on-arrival issue promptly with supporting photos and order details. Return authorization is required.
Warranty duration, coverage, exclusions and return conditions are governed by the written quotation and agreed terms.
Share the part number, equipment details and required condition to coordinate identification, quotation and shipment arrangements.
Send the full part number and your destination details. Include a photo of the board label when available to help confirm identification.
Key points for identification and replacement
Additional industrial automation and drive references
| 71.20-2D | K11R132MX6 | MDSKABS080-22 | Afag LE-70-400 TTL 50307892-400 |
| Siemens 7ME6320-HC12-2AA2 | 17N35-SRMP1-Z0F0-ST5F10N-R0SU | BSM100A375AA | CO-MI-KU-200 |
| 20F4F3R-4R11 | Lenze 33.8610_E 00356139 | Siemens 6AV2128-3XB36-0AX1 | KV67 DY112ML/B/HR/TH/SM41 |
| IC200GBI001-LL | IC200GBI001-GJ | OAK300.1 | 0RMSM1135.4G-EU |
| X20CP1301 | 3AT350.6 | AT350 | DI450 |
| Lewa Ecodos 50S 13-HYG | Siemens 1LA7080-2AA12-Z | SEW RX57 DRN100LS4/MM40/EI76/LN | Lenze MCA 19S42-SRMP1 |
| GMN TSEV 100 SDU x 315 - 6009 | Siemens 2KJ3303-5EM22-9HS1-Z | 404/720+001 | MH300 308746 |
| SEW FH57 DRE100L4/TH | VS311011-ED621002 | KF77R37DRS71S4/RS | MAC112B-0-GB-3-C/130-A-1 |
| Siemens 1FT6105-8AC71-1EG0 | HWI2424 EVA+IQR+ZP | SEW R57 CM3C80S-30A-P/BZ/HR/PK/AK0H/SB1 | VT6DCMY-B20-B12-VL01-C1-IM1212 |
| GGS5000050X0251 50504553 MX1250 600510 | X67AI4850 | X67UM1352 | X20SA4430 |
| X20AIA744 | X20DC11A6 | X20AI1744-3 | AB7649-F |
| DM465 | AI261 | X20PS4951 | NT100-DP-CO |
| X20SL8101 | 80PS080X3.10-01 | 80VD100PS.C02X-01 | X20BC0083 |
| X201F2772 | IC693CPU350-DH | IC695CPU320-G | IC670GBI002H |
| IC670MDL730 | IC670MDL640 | IC695FTB001 | IC200PWR102J |
| IC200MDL650F | IC693CPU374-GS | IC200CMM020-EA | Leuze MLC520R30-1350 |
| Sick LVU 1106-0031 | MAC112D-0-HD-2-C/130-A-1/S05 | Siemens ST31516-4EA00-0AL1-Z | SEW KHF57 DRN100LS4/TF |
| 110-MA3-66-011-000 | SEW RF67 DRE100LC4/TF | FH77/G CM90L/BR/TF/AS1H/SB60 | Siemens 1FT6105-1AC71-4EH1 |
| GFL06-2S HCR 12HC35 MCS 12H35-EQNB0-Z0E0-ST5S00N-R0SU | Dietz Motors FDU 112-115/4 | Siemens 1AV3130A 1LE1023-1CA09-0AB4-Z | KA47/T DRN90L4/TH |
| MXA82A-100-503-00/XGS11A | Lenze MDSKABS090-22 | ABB SACE EMAX2 E1.2 N 630 1SDA072704R1 | 17N17-H20B0-Z0F0-ST5F10N-R0SU |
| KT49 DRN100LS4/TF | Sterling CEHQ 3102 AA DBG0B0 | SEW KT49 DRN100L4/TF | SKF AN13220-126 |
Send your inquiry directly to us