logo
Home > Products > ABB PLC >
ABB PM864AK02 3BSE018164R1 Redundant Processor Unit · 96 MHz / 32 MB

ABB PM864AK02 3BSE018164R1 Redundant Processor Unit · 96 MHz / 32 MB

ABB PM864AK02 redundant processor unit

ABB PLC processor with 96 MHz

ABB PM864AK02 32 MB memory

Place of Origin:

SWEDEN

Brand Name:

ABB

Model Number:

PM864AK02 3BSE018164R1

Contact Us
Request A Quote
Product Details
Highlight:

ABB PM864AK02 redundant processor unit

,

ABB PLC processor with 96 MHz

,

ABB PM864AK02 32 MB memory

Payment & Shipping Terms
Minimum Order Quantity
1
Delivery Time
2-3 work days
Payment Terms
T/T
Product Description
ABB · AC 800M Classic

PM864AK02 Redundant Processor Unit · 96 MHz / 32 MB

Redundant AC 800M processor configuration built with two PM864AK01 processor units. ABB article number 3BSE018164R1.

ABB Article
3BSE018164R1
PM864A Classic · CPU redundancy · AC 800M
01

Overview


PM864AK02 is a redundant processor-unit configuration for the AC 800M controller platform. The package uses two PM864AK01 processor units as the redundant CPU pair.

The PM864A processor uses an MPC862 processor with a 96 MHz clock frequency and 32 MB RAM. CPU redundancy is supported with a maximum switch-over time of 10 ms.

Redundant processor configuration for AC 800M controller systems.
Type PM864AK02
Article Number 3BSE018164R1
Platform AC 800M Classic
Processor MPC862
Configuration Redundant
02

Technical Specifications


PM864A processor and controller specifications.
Processor & Memory
Processor type MPC862 PM864A
Clock frequency 96 MHz PM864A
Memory (RAM) 32 MB
RAM available for application 23.522 MB
Flash memory for application / data Yes
Flash PROM for firmware 2 MB
Performance & Redundancy
CPU redundancy Yes Supported
Switch-over time Max. 10 ms Redundant configuration
1000 Boolean operations 0.15 ms Performance
Protection class IP20
Environmental & EMC
Environmental classification Industrial
EMC emission EN 61000-6-4 Test standard
EMC immunity EN 61000-6-2 Test standard
03

Redundant CPU Architecture


Processor A
PM864AK01 PM864A processor unit
Processor B
PM864AK01 Redundant processor unit
TK850 CEX-Bus expansion cable
TK851 RCU-Link cable
TP830 / TB807 Baseplate / ModuleBus terminator
04

Compatibility & Replacement


Original configuration

PM864AK02 · 3BSE018164R1

Redundant configuration containing two PM864AK01 processor units.

Processor unit

PM864AK01

Single PM864A processor-unit package used within the PM864AK02 redundant configuration.

Migration

Later AC 800M Processor Families

A later processor family should be evaluated as part of a complete controller migration rather than treated as an automatic one-for-one replacement.

05

Application & Fault Scenarios


AC 800M Process Control

Redundant Controller Operation

PM864AK02 is used where an AC 800M controller requires a redundant processor arrangement. It is particularly relevant to maintenance searches involving CPU faults, loss of controller redundancy and planned replacement of PM864A Classic hardware.

01
CPU fault Review processor diagnostics when one processor becomes unavailable.
02
Redundancy lost Check the redundant processor arrangement and associated links.
03
RCU-Link / CEX-Bus issue Inspect cables and associated termination hardware during fault finding.
04
Planned spare replacement Useful for maintaining an identified PM864A Classic spare position.
06

Delivery & Warranty


Testing Pre-shipment identification and available functional inspection.
Packaging Secure export packing for industrial automation equipment.
Warranty 12-month warranty support for product-related defects under agreed terms.
DOA / Returns DOA cases are reviewed against inspection records and order details.
ABB PM864AK02 3BSE018164R1 Redundant Processor Unit · 96 MHz / 32 MB
07

FAQ & Request for Quotation


What is the difference between PM864AK02 and PM864AK01?
PM864AK01 is a single PM864A processor-unit package. PM864AK02 is the redundant configuration using two PM864AK01 processor units.
Does PM864AK02 include the redundant CPU connection hardware?
The PM864AK02 package includes two PM864AK01 processor units, one TK850 CEX-Bus expansion cable and one TK851 RCU-Link cable.
What should be checked when an AC 800M system loses redundancy?
Start with the processor diagnostics, then check the RCU-Link, CEX-Bus path, associated cables and termination hardware.
Can a later AC 800M processor replace PM864AK02 directly?
A later processor family should be evaluated as part of a complete AC 800M migration. Hardware, redundancy architecture and software configuration all need to be compatible.
What information should I send for a PM864AK02 quotation?
Please provide the exact part number, quantity, destination, required date, machine and system model.
Request for Quotation

Need PM864AK02?

Send the exact part number and installation details for quotation.

PM864AK02 / 3BSE018164R1
Required Qty.
Country / City
Target Date
Machine / Equipment
AC 800M / System 800xA
Miya Zheng · AMIKON Industrial Automation
sales@amikon.cn
ABB PM864AK02 · 3BSE018164R1 · AC 800M
AMIKON Industrial Automation

Send your inquiry directly to us