logo
Home > Products > Honeywell Controller >
Honeywell FC-USI-0002 Universal Safety Interface Module

Honeywell FC-USI-0002 Universal Safety Interface Module

Honeywell universal safety interface module

Honeywell controller safety module

Honeywell FC-USI-0002 interface module

Brand Name:

Honeywell

Model Number:

FC-USI-0002

Contact Us
Request A Quote
Product Details
Highlight:

Honeywell universal safety interface module

,

Honeywell controller safety module

,

Honeywell FC-USI-0002 interface module

Product Description

UNIVERSAL SAFETY INTERFACE / SAFETY MANAGER

FC-USI-0002

FC-USI-0002 is a legacy Universal Safety Interface module for Honeywell Safety Manager controller configurations; Honeywell has published a defined successor and replacement path.

Type
Universal Safety Interface module
System
Honeywell Safety Manager
Focus
Legacy controller interface and migration
Brand
Honeywell

Official data

Technical Specifications

Select a group to view verified specifications for this exact model.

View 6 identity and lifecycle specifications
Model / SAP material number FC-USI-0002
Product type Universal Safety Interface module
System Honeywell Safety Manager
Lifecycle status Withdrawn from sales
Published successor FE-USI-0002
Current published replacement FX-USI-0002
View 6 official replacement specifications
FX-USI-0002 compatibility Pin-to-pin and function compatible with FC-USI-0002
Minimum Safety Manager release R140.1 for FX-USI-0002 replacement
Online replacement Supported by Honeywell for FX-USI-0002
Redundant controller use FX-USI-0002 can operate with the older FC-USI-0002 partner
Function after replacement FX-USI-0002 functions as the replaced FC-USI-0002
Early software releases Releases before R140.1 are not supported for FX-USI-0002

Official relationship

Compatibility & Replacement

Honeywell states that FC-USI-0002 was succeeded by FE-USI-0002 and that FX-USI-0002 is the current pin-to-pin, function-compatible replacement. The replacement requires Safety Manager R140.1 or higher and may be performed online; confirm the installed release and redundant partner before the work.

Field context

Applications & Fault Scenarios

Practical symptoms, checks and downtime exposure without extending the manufacturer specification.

01

Legacy USI module fault

Observe: The Safety Manager controller reports a fault associated with the legacy interface module.
Check: Confirm the full FC-USI-0002 label, controller redundancy state and software release before selecting a replacement.
Risk: Incorrect replacement planning can affect controller communication and extend a safety-system outage.
02

Replacement on an early release

Observe: FX-USI-0002 is proposed but the system release is older than R140.1.
Check: Do not proceed as a supported replacement; Honeywell requires R140.1 or higher and recommends upgrading early releases.
Risk: An unsupported software/hardware combination may fail to restore operation.
03

Redundant controller replacement

Observe: One FC-USI-0002 in a redundant controller pair requires replacement.
Check: Verify redundancy health and follow the supported online replacement plan; Honeywell states FX-USI-0002 can work with the older partner.
Risk: Poorly controlled work on the active pair can reduce redundancy or interrupt the controller.

Commercial service

About Amikon & Service

Order review, inspection, dispatch and after-sales support are handled separately from Honeywell technical data.

Amikon customer service discussion
Customer service discussion
Amikon warehouse inventory shelves
Warehouse inventory shelves
Order Review
Part number, quantity and system context checked.
Inspection & Testing
Condition and available checks recorded.
Packing & Dispatch
Protective packing prepared for destination.
DOA & Returns
Prompt evidence review; prior authorization required.
Warranty
Applicable terms stated in the quotation.
After-sales Support
Order-based follow-up from the service team.

RFQ checklist

Send five order details

01  Part Number
02  Quantity
03  Destination
04  Required Date
05  Machine / System Model

Independent sourcing references

Multi-brand Spare Parts Also Requested

Thirty models randomly selected from the supplied list for independent sourcing enquiries.

Notice: These models are independent procurement references only and are not substitutes for FC-USI-0002. Compatibility, configuration and inventory must be confirmed separately for every request.

ABB 1SAP150100R0100
SE-402,AC 300
ABB PM5630-2ETH / 1SAP131000R0378
MIT510/2
33214,PRO-1204-1,400-5595D,AYDIN 900-5595C
AW401/5001
CTS-PHD1080P12XS2
0P2612FC UJ0T33066002 34001170XD-1FB-Z
CQM1 PA216+CPU44-EV1+2xID212+2xOC222
c18,959993-902
450H ADLP-2
A8AF 220VAC/5DC ASSY:MRC006507
GE 104-IS
DP568
CGDMX-512BI
367 113/1-R1B
ASC-300
POI-1501-GPC0E
100-E205KD11
USI-0001
NFDV151-PF0-S2
790-00818-01 001
DS3800XAIH1A1A
Allen Bradley 6181F-15TPXP
CLNXEHS26D100A
GE DIA.NEXT4
ABB 367 113/1-R1B 2012W49
3144P D1A2I1M5F5U1Q4
BBAAD-DAACA-B1
7KG9661-2FA00-1AA0/CC

Six buyer questions for FC-USI-0002

FAQ

Procurement, compatibility and fault questions for this exact model.

Is Honeywell FC-USI-0002 still a current-sale module?

Honeywell states that FC-USI-0002 was withdrawn from sales.

What is the official replacement for Honeywell FC-USI-0002?

Honeywell identifies FX-USI-0002 as the current replacement after the intermediate FE-USI-0002 generation.

Is Honeywell FX-USI-0002 compatible with Honeywell FC-USI-0002?

Yes. Honeywell states it is pin-to-pin and function compatible.

Which software release is required to replace Honeywell FC-USI-0002 with FX-USI-0002?

Safety Manager R140.1 or higher is required for the FX replacement.

Can Honeywell FC-USI-0002 be replaced online with FX-USI-0002?

Honeywell states that online replacement is supported, subject to the required Safety Manager release and site procedure.

Which details should accompany an RFQ for Honeywell FC-USI-0002?

Provide the part number, quantity, destination, required date and the machine or system model.

Send your inquiry directly to us