ICS Triplex T7481A Monitored Guarded Output Module with 16 Field Loads, Fault-Tolerant Operation

ICS Triplex T7481A Monitored Guarded Output Module with 16 Field Loads, Fault-Tolerant Operation

16 Field Loads Output Module

Fault-Tolerant Operation Guarded Control Module

Hot-Replaceable Monitored Guarded Output Module

Place of Origin:

USA

Brand Name:

ICS triplex

Model Number:

T7481A

Contact Us
Request A Quote
Product Details
Estimated Shipping Size:
3.3x26.4x32.7cm
Weight:
1.6 Kg
Voltage Range:
18 To 36 VDC
Heat Dissipation:
30 Watts, 101 BTUs/hour
Operating Temperature:
0° To 60° C (32° To 140° F)
Storage Temperature:
-40° To 85° C (-40° To 185° F)
Operating Humidity:
0 To 95% Relative Humidity, Non-condensing
Vibration(10 To 55 Hz):
±0.15mm
Highlight:

16 Field Loads Output Module

,

Fault-Tolerant Operation Guarded Control Module

,

Hot-Replaceable Monitored Guarded Output Module

Payment & Shipping Terms
Minimum Order Quantity
1
Price
66USD
Packaging Details
Brand new and original
Delivery Time
2-3 work days
Payment Terms
T/T
Supply Ability
in stock
Product Description
ICS Triplex T7481A Monitored Guarded Output Module with 16 Field Loads, Fault-Tolerant Operation 0

Monitored Guarded output modules provide Guarded control and line monitoring for sixteen field loads. Three types of modules are available for interfacing to outputs powered from 24 VDC, 110 VAC, or 120 VDC field power supplies.

These modules are referred to as Guarded because each module's dual-redundant design ensures that no single fault within the module can inadvertently apply power to an output. In addition, the modules monitor the output field wiring for open-circuit and short-circuit faults.

Individual output line status is made available to application programs, allowing continuous supervision of output operation and field wiring integrity.

ICS Triplex T7481A Monitored Guarded Output Module with 16 Field Loads, Fault-Tolerant Operation 1
Output and Fault Tolerance
  • Sixteen Guarded outputs (arranged in two groups of eight)
  • Fault-tolerant operation when connected in parallel with another module of the same type
Maintenance and Service
  • Hot-replaceable for minimal downtime
  • Fuses accessible from the front panel for easy replacement
Diagnostics and Monitoring
  • Complete, automatic testing of all output circuits
  • Automatic line monitoring detects open-circuit and short-circuit field wiring faults
  • Individual front panel indicators show module fault/active status and shutdown state
  • Additional indicators display output status and load/fuse fault for each point
Electrical and Safety Compliance
  • Minimum 2500 V electrical isolation between field and logic circuits
  • TÜV certified, Risk Class 5
ICS Triplex T7481A Monitored Guarded Output Module with 16 Field Loads, Fault-Tolerant Operation 2
Module Configuration Procedure

Each output module is configured using the WINTERPRET I/O Configuration Editor. To configure the module, follow the four steps below:

1. Set the Module Type
  • Position the cursor on the module slot you wish to define
  • Select Set Module Type from the Edit Menu, then choose the appropriate Monitored Guarded Output Module from the list
2. Edit the Module Definition
  • Select Edit Module Definition from the Edit Menu
  • A dialog box will open, allowing you to define the output point definitions for the module
3. Configure Single or Dual Mode
  • With the cursor at the top of the list in the Module Definition dialog, open the Monitored Guarded Output Module Definition dialog by pressing Enter or double-clicking the "(Module)" selection
  • If the module is to operate in dual mode (wired in parallel with another module for fault tolerance), check the Dual Mode selection in the dialog box
  • Enter the I/O Assembly number (1-16) and I/O Slot number (1-10) of the redundant module. This must be done for each of the two modules operating in dual mode
4. Edit Each Output Point
  • From the Module Definition dialog box, select Edit to define a name and description for each output point
  • In the Monitored Guarded Output Point dialog, enter the names and values for the configuration fields as required
ICS Triplex T7481A Monitored Guarded Output Module with 16 Field Loads, Fault-Tolerant Operation 3
Quality parts. No nonsense.

When you order from us, you know exactly what you're getting.

  • Stocked Up: We hold a massive inventory of major brand-name parts. If you need it, we likely have it.
  • 100% Legit: Only Brand New & Original items. No refurbished, no fakes.
  • Tested by Pros: We don't just ship boxes. Our experienced team runs every unit through our testing facility first.
  • Fast Movers: Prompt delivery is our standard. We pack it safe and get it out the door.
Need a reliable partner? We're ready.
Miya Zheng
Sales Manager
+86 180 2077 6792

Send your inquiry directly to us