logo
Huis > producten > BENTLY NEVADA >
Bently Nevada 125720-02 SIL 2 Compliant Hazardous Area Certified 4-Channel Relay Output Module

Bently Nevada 125720-02 SIL 2 Compliant Hazardous Area Certified 4-Channel Relay Output Module

3500/32M Relay Module hazardous environment automation

125720-02 Output Module Bently Nevada 3500 rack

machinery protection relay critical rotating asset protection

Plaats van herkomst:

VS

Merknaam:

Bently Nevada

Modelnummer:

125720-02

Contacteer ons
Verzoek om een Citaat
Productdetails
Model:
125720-02
Land van herkomst:
VS
Plaats van verzending:
Xiamen, China
Verzending:
TNT, DHL, FedEx, EMS, UPS
MOQ:
1 stuk
Verpakking:
Originele nieuwe verpakking
Markeren:

3500/32M Relay Module hazardous environment automation

,

125720-02 Output Module Bently Nevada 3500 rack

,

machinery protection relay critical rotating asset protection

Betaling & het Verschepen Termijnen
Min. bestelaantal
1
Prijs
66USD
Verpakking Details
Gloednieuw en origineel
Levertijd
2-3 werkdagen
Betalingscondities
T/T
Levering vermogen
Op voorraad
Productomschrijving
Bently Nevada 125720-02 Spare 4-Channel Relay Output Module
Bently Nevada 125720-02 SIL 2 Compliant Hazardous Area Certified 4-Channel Relay Output Module 0
Category Specification Parameter Official Data Detail
Identity Manufacturer Bently Nevada

Part Number 125720-02

Product Type Spare 4-Channel Relay Output Module
System Environment Application Scope Specialized for Hazardous Area and Functional Safety Systems

Safety Integrity Level Capable of supporting SIL 2 system architectures
Hardware Layout Number of Channels 4 Independent Relay Channels

Contact Type Single-Pole, Double-Throw (SPDT)
Electrical Ratings
(Resistive Loads)
Maximum Switched Voltage 30 Vdc / 30 Vac (Restricted for safety)

Maximum Switched Current 2 A

Minimum Switched Load 100 mA @ 12 Vdc
Environmental Limits Operating Temperature -30°C to +65°C (-22°F to +149°F)
Need an Instant Quote?

Contact: Miya Zheng

Email: sales@amikon.cn

WhatsApp: +86 180 2077 6792

Bently Nevada 125720-02 SIL 2 Compliant Hazardous Area Certified 4-Channel Relay Output Module 1
For a process expansion, we got DCS-compatible sensors from Amikon, no changes needed, no downtime.
On a packaging line update, their advice on sensor position and controller choice made the line run smoother, fewer errors.
During an emergency shutdown, they shipped parts overnight and guided the install, helped avoid production loss.
They also found old PLC modules that were no longer available, so we could keep the old lines running without redesign.
Bently Nevada 125720-02 SIL 2 Compliant Hazardous Area Certified 4-Channel Relay Output Module 2 Bently Nevada 125720-02 SIL 2 Compliant Hazardous Area Certified 4-Channel Relay Output Module 3
Key Features
  • SIL 2 & Hazardous Area Certified Compliance
    Engineered specifically for hazardous area deployment and functional safety systems. Fully certified to support SIL 2 compliant safety system architectures, guaranteeing reliable operation in explosive and high-risk industrial environments.
  • Advanced 4-Channel AND/OR Voting Logic
    Features 4 independent relay channels that support programmable AND/OR voting logic control. Allows precise customization of emergency trip and alarm triggers based on multi-channel inputs from the 3500 rack.
  • Fail-Safe Machinery Emergency Shutdown (ESD)
    Acts as the critical hardware link for machinery emergency shutdown (ESD) and emergency trip systems (ETS). Instantly executes over-speed trips and emergency stops to provide ultimate critical asset protection for rotating machinery.
  • Flexible SPDT Contact Configuration
    Equipped with standard Single-Pole, Double-Throw (SPDT contact switching) layouts. Offers both Normally Open (NO) and Normally Closed (NC) dry contacts to easily integrate into diverse industrial automation interlock and alarm status relay output loops.
  • Seamless 3500 System & TDI Integration
    Designed exclusively for the Bently Nevada 3500 rack, providing 100% plug-and-play TDI module integration. Fully configurable via standard 3500/01 configuration software as high-reliability 3500/32 relay system spares.
Bently Nevada 125720-02 SIL 2 Compliant Hazardous Area Certified 4-Channel Relay Output Module 4
Application Areas
  • Emergency Shutdown Systems (ESD) & Emergency Trip Systems (ETS)
    Serves as the primary hardware execution interface for machinery emergency shutdown (ESD). It relays critical trip commands to instantly isolate or shut down high-risk machinery during catastrophic failure events.
  • SIL 2 Compliant Safety Interlock Loop Integration
    Deployed in high-integrity automation loops that require certified SIL 2 compliant safety system architectures. It manages the alarm status relay output and fail-safe voting actions to prevent operational common-mode failures.
  • Hazardous Environment Automation Control
    Optimized for hazardous area safety interface tasks within Class I, Division 2 / Zone 2 environments. It safely bridges the gap between digital monitoring chassis logic and field-located physical actuators without risks of ignition.
  • Critical Rotating Asset Protection for Turbomachinery
    Protects vital heavy-industry assets including steam turbine monitoring networks, gas turbine protection setups, and massive centrifugal compressor monitors. It monitors severe fault indicators like over-speed or high radial vibration to initiate defensive trips.
  • Oil & Gas and Power Plant Instrumentation Loops
    Used in refineries, petrochemical plants, offshore platforms. API 670 interlocking for protection loops, equipment and personnel safety.
Bently Nevada 125720-02 SIL 2 Compliant Hazardous Area Certified 4-Channel Relay Output Module 5
Frequently Asked Questions
Q1: What is the function of the Bently Nevada 125720-02 module in a 3500 system?
A: 4-channel relay output module in 3500/32M. Takes alarm from rack, turns into relay outputs for shutdown / trip / alarm via AND/OR logic. Mainly machinery protection use.
Q2: What is the difference between 125720-02 and 125720-01?
A: 125720-01 for normal industrial. 125720-02 for hazardous / safety systems. 30 Vac / 30 Vdc limit, usually SIL 2 related applications, oil & gas side.
Q3: Where is the 125720-02 usually applied?
A: Turbines, compressors, rotating equipment. Refineries, power plants. Protection loop, triggers shutdown when vibration / thrust out of range.
Q4: What are the relay specs of the 125720-02?
A: 4 SPDT channels, NO/NC contacts. 2A max, 30 Vdc / 30 Vac. 100 mA minimum load @ 12 Vdc.
Q5: How is the 125720-02 installed in a 3500 rack?
A: Rear I/O behind 3500/32M. Config in 3500/01 software. Works with TDI and rack processor, integration is straightforward.
Bently Nevada 125720-02 SIL 2 Compliant Hazardous Area Certified 4-Channel Relay Output Module 6
Compatible Part Numbers
330730-080-12-CN
990-04-70-01-00
31000 SC115582-1
330103-00-15-05-01-00
330100-50-05
330905-00-10-10-02-00
330705-02-18-90-02-00
991-06-50-01-00
76683-50
330103-00-15-10-02-00
330101-00-40-10-02-00-CN
1X35668
330910-05-11-10-02-00
330103-02-07-10-02-00
130118-0050-02
330103-02-12-10-02-00
330101-XX-XX-10-02-CN
330103-05-13-10-02-00
330103-00-05-10-01-00
330103-07-12-10-02-00
330103-02-06-05-02-00
330104-01-05-10-02-00
330103-05-12-10-01-00
330703-050-120-10-02-00
330101-24-35-10-02-00
330709-050-120-10-02-00
84661-6
76686-040-01
330103-00-04-15-02-CN
81305-040-00
330103-00-05-10-02-CN
135489-04
330106-05-30-20-02-CN
128031-01C 128031-01
330130-070-00-CN
330904-05-14-05-02-00
170180-01-00
330930-040-00-00
330130-075-00-CN
330909-00-60-10-02-05

Rechtstreeks uw onderzoek naar verzend ons